Engineering design for the magnetic diagnostics of Wendelstein 7-X

被引:37
|
作者
Endler, M. [1 ]
Brucker, B. [1 ]
Bykov, V. [1 ]
Cardella, A. [1 ]
Cads, A. [1 ]
Dobmeier, F. [1 ]
Dudek, A. [1 ]
Fellinger, J. [1 ]
Geiger, J. [1 ]
Grosser, K. [1 ]
Grulke, O. [1 ]
Hartmann, D. [1 ]
Hathiramani, D. [1 ]
Hoechel, K. [1 ]
Koeppen, M. [1 ]
Laube, R. [1 ]
Neuner, U. [1 ]
Peng, X. [1 ]
Rahbarnia, K. [1 ]
Rummel, K. [1 ]
Sieber, T. [1 ]
Thiel, S. [1 ]
Vorkoeper, A. [1 ]
Werner, A. [1 ]
Windisch, T. [1 ]
Ye, M. Y. [1 ]
机构
[1] Max Planck Inst Plasma Phys, D-17491 Greifswald, Germany
关键词
Stellarator; Wendelstein; 7-X; Magnetic diagnostics; ANISOTROPIC PRESSURE; W7-X; PHYSICS; OPERATION; PLASMA;
D O I
10.1016/j.fusengdes.2015.07.020
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The magnetic diagnostics foreseen for the Wendelstein 7-X (W7-X) stellarator are diamagnetic loops to measure the plasma energy, Rogowski coils to measure the toroidal plasma current, saddle coils to measure the Pfirsch-Schluter currents, segmented Rogowski coils (poloidal magnetic field probes) to add information on the distribution of the plasma current density, and Mirnov coils to observe magnetohy-drodynamic modes. All these magnetic field sensors were designed as classical pick-up coils, after the time integration of induced signals for 1/2 hour had been successfully demonstrated. The long-pulse operation planned for W7-X causes nevertheless significant challenges to the design of these diagnostics, in particular for the components located inside the plasma vessel, which may be exposed to high levels of microwave (electron cyclotron resonance) stray radiation and thermal radiation. This article focuses on the tests and modelling performed during the development of the magnetic diagnostics and on the design solutions adopted to meet the conflicting requirements. All pick-up coils foreseen for the initial operation phase of W7-X and their signal cable sections inside the plasma vessel and the cryostat are now installed, and their electronics and data acquisition are under preparation. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:468 / 494
页数:27
相关论文
共 50 条
  • [1] Bayesian design of diagnostics: Case studies for Wendelstein 7-X
    Dreier, H.
    Dinklage, A.
    Fischer, R.
    Hirsch, M.
    Kornejew, P.
    Pasch, E.
    FUSION SCIENCE AND TECHNOLOGY, 2006, 50 (02) : 262 - 267
  • [2] Neutron diagnostics at the Wendelstein 7-X stellarator
    Schneider, W.
    Wiegel, B.
    Gruenauer, F.
    Burhenn, R.
    Koch, S.
    Schuhmacher, H.
    Zimbal, A.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [3] Design and construction of WENDELSTEIN 7-X
    Wanner, M
    Feist, JH
    Renner, H
    Sapper, J
    Schauer, F
    Schneider, H
    Erckmann, V
    Niedermeyer, H
    FUSION ENGINEERING AND DESIGN, 2001, 56-57 : 155 - 162
  • [4] Proposed neutron diagnostics for Wendelstein 7-X stellarator
    Elevant, T.
    Wolle, B.
    Weller, A.
    Review of Scientific Instruments, 1999, 70 (1 pt 2):
  • [5] Proposed neutron diagnostics for Wendelstein 7-X stellarator
    Elevant, T
    Wolle, B
    Weller, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 1185 - 1189
  • [6] Concepts of x-ray diagnostics for WENDELSTEIN 7-X
    Weller, A
    Mohr, S
    Junghans, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3962 - 3965
  • [7] Continuous data acquisition with online analysis for the Wendelstein 7-X magnetic diagnostics
    Hennig, Ch.
    Werner, A.
    Marquardt, M.
    Bluhm, I.
    Kroiss, H.
    Kuehner, G.
    Heimann, P.
    Maier, J.
    Riemann, H.
    Zilker, M.
    FUSION ENGINEERING AND DESIGN, 2008, 83 (2-3) : 321 - 325
  • [8] Diagnostics design for steady-state operation of the Wendelstein 7-X stellarator
    Koenig, R.
    Baldzuhn, J.
    Biel, W.
    Biedermann, C.
    Burhenn, R.
    Bozhenkov, S.
    Cantarini, J.
    Dreier, H.
    Endler, M.
    Hartfuss, H. -J.
    Hildebrandt, D.
    Hirsch, M.
    Jakubowski, M.
    Jimenez-Gomez, R.
    Kocsis, G.
    Kornejev, P.
    Krychowiak, M.
    Laqua, H. P.
    Laux, M.
    Oosterbeek, J. W.
    Pasch, E.
    Richert, T.
    Schneider, W.
    Schweer, B.
    Svensson, J.
    Thomsen, H.
    Weller, A.
    Werner, A.
    Wolf, R.
    Zhang, D.
    Zoletnik, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [9] Design of the ECE diagnostic at Wendelstein 7-X
    Schmuck, S.
    Hartfuss, H. -J.
    Hirsch, M.
    Stange, T.
    FUSION ENGINEERING AND DESIGN, 2009, 84 (7-11) : 1739 - 1743
  • [10] Setup and initial results from the magnetic flux surface diagnostics at Wendelstein 7-X
    Otte, M.
    Assmus, D.
    Biedermann, C.
    Bozhenkov, S.
    Braeuer, T.
    Dudek, A.
    Geiger, J.
    Kocsis, G.
    Lazerson, S.
    Pedersen, T. S.
    Schauer, F.
    Szepesi, T.
    Standley, B.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2016, 58 (06)