Determination of optical parameters of pulp suspensions by time-resolved detection of photoacoustic signals and total diffuse reflectance measurements

被引:1
|
作者
Zhao, Zuomin [1 ]
Tormanen, Matti [1 ]
Myllyla, Risto [1 ]
机构
[1] Univ Oulu, Dept Elect & Informat Engn & Infotech Oulu, Oulu 90014, Finland
来源
CENTRAL EUROPEAN JOURNAL OF PHYSICS | 2010年 / 8卷 / 02期
关键词
time-resolved photoacoustic; diffuse reflectance; optical parameters; pulp suspensions; kappa number; consistency; TURBID MEDIA;
D O I
10.2478/s11534-009-0091-z
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Time-resolved photoacoustics were used to measure the optical parameters of pulp suspensions for the first time. Reconstructing stress distribution along the direction of the incident laser light allows the effective attenuation coefficient of these suspensions to be determined. Simultaneously, the total diffuse reflectance of the suspensions was measured by the same laser source. Based on the effective attenuation coefficient and total diffuse reflectance, the absorption and reduced scattering coefficients of pulp suspensions can be calculated. In this study, three kinds of pulp suspensions with different kappa number (2, 13, and 16), a measure of lignin content in pulp fibers, were diluted with water to make samples with a consistency range from 1% to 5%, and studied at 355 nm wavelength. The results showed that the optical coefficients were approximately proportional to pulp consistency; on the other hand, the absorption coefficient was linearly correlated with kappa number, but the reduced scattering coefficient was not. Therefore, by determining its optical parameters, it is possible to extract the consistency and kappa number of an unknown pulp suspension.
引用
收藏
页码:221 / 227
页数:7
相关论文
共 50 条
  • [1] Determination of the optical properties of multilayered phantoms by time-resolved reflectance measurements
    Garcia, H.
    Iriarte, D.
    Pomarico, J.
    Grosenick, D.
    Macdonald, R.
    DIFFUSE OPTICAL IMAGING V, 2015, 9538
  • [2] Instrument response function acquisition in reflectance geometry for time-resolved diffuse optical measurements
    Pirovano, Ileana
    Re, Rebecca
    Candeo, Alessia
    Contini, Davide
    Torricelli, Alessandro
    Spinelli, Lorenzo
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (01) : 240 - 250
  • [3] Instrument response function acquisition in reflectance geometry for time-resolved diffuse optical measurements
    Pirovano, Ileana
    Re, Rebecca
    Contini, Davide
    Spinelli, Lorenzo
    Torricelli, Alessandro
    DIFFUSE OPTICAL SPECTROSCOPY AND IMAGING VII, 2019, 11074
  • [4] Determination of tissue optical properties by time-resolved reflectance
    Liu, XL
    Zhang, R
    Bao, HJ
    Zhong, JK
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 460 - 461
  • [5] THE POTENTIAL OF TIME-RESOLVED REFLECTANCE MEASUREMENTS FOR THE NONINVASIVE DETERMINATION OF TISSUE OPTICAL-PROPERTIES
    WILSON, B
    PARK, Y
    HEFETZ, Y
    PATTERSON, M
    MADSEN, S
    JACQUES, S
    THERMAL AND OPTICAL INTERACTIONS WITH BIOLOGICAL AND RELATED COMPOSITE MATERIALS, 1989, 1064 : 97 - 106
  • [6] DETERMINATION OF 2 ORDER PARAMETERS FROM TIME-RESOLVED FLUORESCENCE ANISOTROPY MEASUREMENTS IN MEMBRANE SUSPENSIONS
    AMELOOT, M
    VANDERMEER, W
    POTTEL, H
    HERREMAN, W
    HENDRICKX, H
    ARCHIVES INTERNATIONALES DE PHYSIOLOGIE DE BIOCHIMIE ET DE BIOPHYSIQUE, 1983, 91 (03): : BP13 - BP14
  • [7] Development of time-resolved reflectance diffuse optical tomography for breast cancer monitoring
    Yoshimoto, Kenji
    Ohmae, Etsuko
    Yamashita, Daisuke
    Suzuki, Hiroaki
    Homma, Shu
    Mimura, Tetsuya
    Wada, Hiroko
    Suzuki, Toshihiko
    Yoshizawa, Nobuko
    Nasu, Hatsuko
    Ogura, Hiroyuki
    Sakahara, Harumi
    Yamashita, Yutaka
    Ueda, Yukio
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE XII, 2017, 10059
  • [8] Influence Factors for the Optical Parameters Measurement with Time-resolved Diffusion Reflectance
    Yu, Biying
    Li, Hui
    Yang, Hongqin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS VI, 2009, 7176
  • [9] Detection of cortical activation with time-resolved diffuse optical methods
    Montcel, B
    Chabrier, R
    Poulet, P
    APPLIED OPTICS, 2005, 44 (10) : 1942 - 1947
  • [10] Time-resolved fluorescence and diffuse reflectance for lung squamous carcinoma margin detection
    Costa, Sarah
    Fang, Qiyin
    Farrell, Thomas
    Dao, Erica
    Farquharson, Michael
    LASERS IN SURGERY AND MEDICINE, 2024, 56 (03) : 279 - 287