The use of femoral stems with exchangeable necks in primary total hip arthroplasty increases the rate of revision

被引:33
|
作者
Graves, S. E. [2 ]
de Steiger, R. [2 ]
Davidson, D. [2 ]
Donnelly, W. [2 ]
Rainbird, S. [2 ]
Lorimer, M. F. [1 ,3 ]
Cashman, K. S. [1 ,3 ]
Vial, R. J. [4 ]
机构
[1] Australian Orthopaed Assoc, Natl Joint Replacement Registry, Adelaide, SA, Australia
[2] Australian Orthopaed Assoc, Natl Joint Replacement Registry, South Australian Hlth & Med Res Inst, Level 4, Adelaide, SA 5000, Australia
[3] South Australian Hlth & Med Res Inst, Level 4, Adelaide, SA 5000, Australia
[4] Australian Orthopaed Assoc, Natl Joint Replacement Registry, South Australian Hlth & Med Res Inst 1, Level 4, Adelaide, SA 5000, Australia
来源
BONE & JOINT JOURNAL | 2017年 / 99B卷 / 06期
关键词
LOCAL TISSUE REACTION; FRETTING WEAR; CORROSION; FAILURE; COMPONENT; JUNCTION; FRACTURE; DISSOCIATION; DISLOCATION; PROSTHESIS;
D O I
10.1302/0301-620X.99B6.38020
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims Femoral stems with exchangeable (modular) necks were introduced to offer surgeons an increased choice when determining the version, offset and length of the femoral neck during total hip arthroplasty (THA). It was hoped that this would improve outcomes and reduce complications, particularly dislocation. In 2010, the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) first reported an increased rate of revision after primary THA using femoral stems with an exchangeable neck. The aim of this study was to provide a more comprehensive up-to-date analysis of primary THA using femoral stems with exchangeable and fixed necks. Materials and Methods The data included all primary THA procedures performed for osteoarthritis (OA), reported to the AOANJRR between 01 September 1999 and 31 December 2014. There were 9289 femoral stems with an exchangeable neck and 253 165 femoral stems with a fixed neck. The characteristics of the patients and prostheses including the bearing surface and stem/neck metal combinations were examined using Cox proportional hazard ratios (HRs) and Kaplan-Meier estimates of survivorship. Results It was found that prostheses with an exchangeable neck had a higher rate of revision and this was evident regardless of the bearing surface or the size of the femoral head. Exchangeable neck prostheses with a titanium stem and a cobalt-chromium neck had a significantly higher rate of revision compared with titanium stem/titanium neck combinations (HR 1.83, 95% confidence interval 1.49 to 2.23, p < 0.001). Revisions were higher for these combinations compared with femoral stems with a fixed neck. Conclusion There appears to be little evidence to support the continued use of prostheses with an exchangeable neck in primary THA undertaken for OA.
引用
收藏
页码:766 / 773
页数:8
相关论文
共 50 条
  • [1] Modular Femoral Stems for Revision Total Hip Arthroplasty
    Restrepo, Camilo
    Mashadi, Magdalena
    Parvizi, Javad
    Austin, Matthew S.
    Hozack, William J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) : 476 - 482
  • [2] Revision Total Hip Arthroplasty With Modular Femoral Stems
    Stimac, Jeffrey D.
    Boles, John
    Parkes, Natalie
    Della Valle, Alejandro Gonzalez
    Boettner, Friedrich
    Westrich, Geoffrey H.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (11): : 2167 - 2170
  • [3] Bimodular femoral stems in primary total hip arthroplasty
    Zajc, Jan
    Fokter, Samo K.
    EXPERT REVIEW OF MEDICAL DEVICES, 2023, 20 (12) : 1051 - 1064
  • [4] The use of long cemented stems for femoral impaction grafting in revision total hip arthroplasty
    Sierra, Rafael J.
    Charity, John
    Tsiridis, Eleftherios
    Timperley, John A.
    Gie, Graham A.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (06): : 1330 - 1336
  • [5] A Role for Modern Primary Cementless Femoral Stems in Revision Hip Arthroplasty
    Skibicki, Hope E.
    Post, Zachary D.
    Kay, Andrew B.
    Czymek, Miranda M.
    Ong, Alvin C.
    Orozco, Fabio R.
    Ponzio, Danielle Y.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (09): : 3269 - 3274
  • [6] Failure mechanisms in CoCrMo modular femoral stems for revision total hip arthroplasty
    Wang, Qiong
    Parry, Michael
    Masri, Bassam A.
    Duncan, Clive
    Wang, Rizhi
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2017, 105 (06) : 1525 - 1535
  • [7] Can Cemented Femoral Stems Be Used During Revision Total Hip Arthroplasty?
    Hoveidaei, Amir Human
    Pirahesh, Kasra
    Sezgin, Erdem Aras
    Devito, Fabio Stucchi
    Hubble, Matthew
    Nikolaev, Nikolai S.
    Sanz-Ruiz, Pablo
    Burgo, Federico Jose
    Citak, Mustafa
    JOURNAL OF ARTHROPLASTY, 2025, 40 (02): : S176 - S179
  • [8] Simultaneous primary total hip arthroplasty and contralateral revision hip arthroplasty - Role for use of femoral head autograft
    Klein, Gregg R.
    Parvizi, Javad
    Shastri, Shani
    Frank, Harrison G.
    Sharkey, Peter F.
    Hozack, William J.
    JOURNAL OF ARTHROPLASTY, 2006, 21 (04): : 527 - 532
  • [9] Modular revision stems in total hip arthroplasty
    Jones, RE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (420) : 142 - 147
  • [10] The use of proximal fixed modular stems in revision of total hip arthroplasty
    Higuera, Carlos A.
    Hanna, George
    Florjancik, Karen
    Allan, D. Gordon
    Robinson, Raymond
    Barsoum, Wael K.
    JOURNAL OF ARTHROPLASTY, 2006, 21 (04): : 112 - 116