Optimum design of cooling water systems for energy and water conservation

被引:82
|
作者
Panjeshahi, M. H. [1 ]
Ataei, A. [2 ]
Gharaie, M. [3 ]
Parand, R. [3 ]
机构
[1] Univ Tehran, Dept Chem Engn, Tehran, Iran
[2] Azad Univ, Environm & Energy Dept, Tehran, Iran
[3] KN Toosi Univ Technol, Dept Mech Engn, Tehran, Iran
来源
关键词
Re-circulating cooling water system; Cooling tower; Pinch technology; Mathematical programming; Ozone treatment; Water-energy conservation;
D O I
10.1016/j.cherd.2008.08.004
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Re-circulating cooling water systems (RCWSs) are widely used to reject waste process heat to the environment, conserve fresh water and reduce thermal pollution relative to once-through systems. Research on RCWS has mostly focused on individual components, cooling tower and heat-exchanger network. Kim and Smith [Kim, J.K. and Smith, R., 2001, Cooling water system design, Chem Eng Sci, 56(12): 3641-3658] developed a grass-root design method of RCWS (KSD). In this paper, the KSD method is expanded and a comprehensive simulation model of RCWS is developed accounting for interaction between cooling tower and heat-exchanger network. Regarding this model, a modern grass-root design method of RCWS, we call it Advanced Pinch Design (APD), based on combined pinch technology and mathematical programming is developed for minimum cost achievement. Having considered cycle water quality through introducing ozone treatment technology, APD methodology is further improved. This technique that we call Enhanced Cooling Water System Design (ECWSD), as the APD supplementary methodology, is provided water and energy conservation, minimum cost and environmental impacts. Related coding in MATLAB version 7.1 is developed for the illustrative example to get optimal values in RCWS design method computations. Finally the results of the introduced grass-root design methodologies, APD and ECWSD, are compared with KSD. Crown Copyright (C) 2008 Published by Elsevier B.V. on behalf of The Institution of Chemical Engineers. All rights reserved.
引用
收藏
页码:200 / 209
页数:10
相关论文
共 50 条
  • [1] Application of an environmentally optimum cooling water system design to water and energy conservation
    Panjeshahi, M. H.
    Ataei, A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2008, 5 (02) : 251 - 262
  • [2] Application of an environmentally optimum cooling water system design in water and energy conservation
    M. H. Panjeshahi
    A. Ataei
    International Journal of Environmental Science & Technology, 2008, 5 : 251 - 262
  • [3] Optimum Design and Operation of an HVAC Cooling Tower for Energy and Water Conservation
    Cutillas, Clemente Garcia
    Ramirez, Javier Ruiz
    Miralles, Manuel Lucas
    ENERGIES, 2017, 10 (03):
  • [4] Application of ozone treatment and pinch technology in cooling water systems design for water and energy conservation
    Ataei, A.
    Gharaie, M.
    Parand, R.
    Panjeshahi, E.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2010, 34 (06) : 494 - 506
  • [5] Water conservation and reuse in cooling water systems
    San Antonio Water System
    不详
    Mater Perform, 2006, 5 (38-40):
  • [6] Water conservation and reuse in cooling water systems
    Wilcut, E
    Rios, S
    MATERIALS PERFORMANCE, 2006, 45 (05) : 38 - 40
  • [7] Application of ozone treatment in cooling water systems for energy and chemical conservation
    Ataei, Abtin
    Mirsaeed, Morteza Ghazi
    Choi, Jun-Ki
    Lashkarboluki, Reza
    ADVANCES IN ENVIRONMENTAL RESEARCH-AN INTERNATIONAL JOURNAL, 2015, 4 (03): : 155 - 172
  • [8] Design of Energy Saving Controllers for Central Cooling Water Systems
    Lee, Chang-Min
    Jeon, Tae-Youl
    Jung, Byung-Gun
    Lee, Young-Chan
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2021, 9 (05)
  • [9] COOLING WATER SYSTEMS: MAINTAINING OPTIMUM EFFICIENCY.
    Cappeline, G.A.
    Townsend, J.R.
    Power Engineering (Barrington, Illinois), 1976, 80 (09): : 60 - 63
  • [10] COOLING WATER-SYSTEMS - MAINTAINING OPTIMUM EFFICIENCY
    CAPPELINE, GA
    TOWNSEND, JR
    POWER ENGINEERING, 1976, 80 (09) : 60 - 63