Surveillance of indoor air quality in ice skating rinks

被引:16
|
作者
Yoon, DW [1 ]
Lee, KY [1 ]
Yanagisawa, Y [1 ]
Spengler, JD [1 ]
Hutchinson, P [1 ]
机构
[1] HARVARD UNIV, SCH PUBL HLTH, DEPT ENVIRONM HLTH, ENVIRONM SCI & ENGN PROGRAM, BOSTON, MA 02115 USA
关键词
D O I
10.1016/0160-4120(96)00016-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Indoor nitrogen dioxide concentrations in 19 ice skating rinks in the greater Boston area were monitored for one week each month, over a four-month period. Nitrogen dioxide was selected as an indicator of indoor air quality, and NO2 samplers were placed in two locations within each rink. Rinks with higher NO2 levels (in excess of 200 nL/L), under normal operation, in the first monitoring week were mitigated with changes in ventilation system operation in the subsequent months. After the first monitoring period, only two rinks had NO2 levels above 200 nL/L. It was suspected that high levels in these two rinks may have been related to improper ventilation. While high NO2 concentrations were found in the ice skating rinks with propane-powered ice resurfacers, other studies indicate that combustion fuels can also result in elevated indoor concentrations. In order to achieve healthful air quality in indoor ice rinks, it may be necessary to: 1) monitor indoor pollution on a continuous or routine basis; 2) educate rink managers on proper ventilation procedures; and 3) test ventilation systems to ensure that their design and operation are effective.
引用
收藏
页码:309 / 314
页数:6
相关论文
共 50 条
  • [1] Indoor air quality in ice skating rinks in Hong Kong
    Guo, H
    Lee, SC
    Chan, LY
    ENVIRONMENTAL RESEARCH, 2004, 94 (03) : 327 - 335
  • [2] Determinants of nitrogen dioxide concentrations in indoor ice skating rinks
    Levy, JI
    Lee, K
    Yanagisawa, Y
    Hutchinson, P
    Spengler, JD
    AMERICAN JOURNAL OF PUBLIC HEALTH, 1998, 88 (12) : 1781 - 1786
  • [3] Ventilation and air quality in indoor ice skating arenas
    Yang, Chunxin
    Demokritou, Philip
    Chen, Qingyan
    Spengler, John
    Parsons, Austin
    ASHRAE Transactions, 2000, 106 (PA : 338 - 346
  • [4] MODERNIZING AND RETROFITTING ICE SKATING RINKS
    BLADES, RW
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1992, 34 (04): : 34 - &
  • [5] Influence of Advertising Banners and Team Logos on the Temperature Regime of Ice of Indoor Ice Skating Rinks, Built Into the Ice Plate
    Livanskiy, D. G.
    SCIENCE & TECHNIQUE, 2023, 22 (06): : 500 - 507
  • [6] CARBON-MONOXIDE IN INDOOR ICE SKATING RINKS - EVALUATION OF ABSORPTION BY ADULT HOCKEY PLAYERS
    LEVESQUE, B
    DEWAILLY, E
    LAVOIE, R
    PRUDHOMME, D
    ALLAIRE, S
    AMERICAN JOURNAL OF PUBLIC HEALTH, 1990, 80 (05) : 594 - 598
  • [7] STUDIES OF PROPERTIES OF ICE IN SPEED-SKATING RINKS
    KOBAYASHI, T
    ASHRAE JOURNAL, 1973, 15 (01) : 51 - 56
  • [8] Blades of Glory ICE SKATING RINKS IN HISTORIC SETTINGS
    Flynn, Katherine
    Keane, Katharine
    PRESERVATION, 2017, 69 (01): : 52 - 53
  • [9] NITROGEN-DIOXIDE EXPOSURES INSIDE ICE SKATING RINKS
    BRAUER, M
    SPENGLER, JD
    AMERICAN JOURNAL OF PUBLIC HEALTH, 1994, 84 (03) : 429 - 433
  • [10] REDUCTION OF AIR POLLUTANT CONCENTRATIONS IN AN INDOOR ICE-SKATING RINK
    LEE, KY
    YANAGISAWA, Y
    SPENGLER, JD
    ENVIRONMENT INTERNATIONAL, 1994, 20 (02) : 191 - 199