Shear-wave Amplitudes Measured with Cardiac MR Elastography for Diagnosis of Diastolic Dysfunction

被引:32
|
作者
Elgeti, Thomas [1 ]
Knebel, Fabian [2 ]
Haettasch, Robert [2 ]
Hamm, Bernd [1 ]
Braun, Juergen [3 ]
Sack, Ingolf [1 ]
机构
[1] Charite, Dept Radiol, D-10117 Berlin, Germany
[2] Charite, Dept Cardiol Angiol & Pulmonol, D-10117 Berlin, Germany
[3] Charite, Inst Med Informat, D-10117 Berlin, Germany
关键词
MAGNETIC-RESONANCE ELASTOGRAPHY; MYOCARDIAL STIFFNESS; HEART-FAILURE; EUROPEAN-SOCIETY; FORCE; ECHOCARDIOGRAPHY; RECOMMENDATIONS; GUIDELINES; VIBRATION; LAMB;
D O I
10.1148/radiol.13131605
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To test whether shear-wave amplitudes (SWAs) in the myocardium measured with cardiac magnetic resonance (MR) elastography enable diagnosis of myocardial relaxation abnormalities in patients with diastolic dysfunction. Materials and Methods: Each subject gave written informed consent to participate in this institutional review board-approved prospective study. Electrocardiographically triggered SWA-based cardiac MR elastography with 24.13-Hz external vibration frequency was performed in 50 subjects grouped into asymptomatic young (n = 10, 18-39 years) and asymptomatic old (n = 10, 40-68 years) subjects and patients with echocardiographically proved mild, moderate, or severe diastolic dysfunction (n = 30, 44-73 years). SWA images were analyzed in the left ventricular (LV) region and were normalized against reference SWA of the thoracic wall. Analysis of variance with Bonferroni-corrected pairwise comparison and Pearson correlation were used for statistical evaluation. Results: Young and old control subjects had normalized mean LV SWA of 0.67 +/- 0.04 (standard error of the mean) and 0.56 +/- 0.04 (P = .18, F test), respectively. Compared with the control groups, patients with mild, moderate, and severe diastolic dysfunction displayed significantly reduced normalized mean LV SWA of 0.37 +/- 0.04, 0.34 +/- 0.04, and 0.29 +/- 0.04 (P < .001, F test), respectively, which was inversely correlated to the severity of diastolic dysfunction (R = -0.61, P < .001). The best cutoff value to differentiate between asymptomatic volunteers and patients was 0.43, yielding an area under the receiver operating characteristic curve of 0.92, with 90% sensitivity and 89.7% specificity. Conclusion: LV SWA measured with cardiac MR elastography provides image contrast sensitive to myocardial relaxation abnormalities and shows significantly lower values in patients with diastolic dysfunction. (C) RSNA, 2014
引用
收藏
页码:681 / 687
页数:7
相关论文
共 50 条
  • [1] Time-Resolved Analysis of Left Ventricular Shear Wave Amplitudes in Cardiac Elastography for the Diagnosis of Diastolic Dysfunction
    Elgeti, Thomas
    Steffen, Ingo G.
    Knebel, Fabian
    Haettasch, Robert
    Hamm, Bernd
    Braun, Juergen
    Sack, Ingolf
    INVESTIGATIVE RADIOLOGY, 2016, 51 (01) : 1 - 6
  • [2] Measuring shear-wave speed with point shear-wave elastography and MR elastography: a phantom study
    Kishimoto, Riwa
    Suga, Mikio
    Koyama, Atsuhisa
    Omatsu, Tokuhiko
    Tachibana, Yasuhiko
    Ebner, Daniel K.
    Obata, Takayuki
    BMJ OPEN, 2017, 7 (01):
  • [3] Measured Hyperelastic Properties of Cervical Tissue with Shear-Wave Elastography
    Ge, Weirong
    Brooker, Graham
    Mogra, Ritu
    Hyett, Jon
    SENSORS, 2022, 22 (01)
  • [4] Shear-wave elastography in the diagnosis of ulnar tunnel syndrome
    Paluch, L.
    Noszczyk, B. H.
    Walecki, J.
    Osiak, K.
    Kicinski, M.
    Pietruski, P.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2018, 71 (11): : 1593 - 1599
  • [5] Hepatic Fibrosis: Prospective Comparison of MR Elastography and US Shear-Wave Elastography for Evaluation
    Yoon, Jeong Hee
    Lee, Jeong Min
    Joo, Ijin
    Lee, Eun Sun
    Sohn, Ji Young
    Jang, Suk Ki
    Lee, Kyung Bun
    Han, Joon Koo
    Choi, Byung Ihn
    RADIOLOGY, 2014, 273 (03) : 772 - 782
  • [6] Shear-Wave Elastography for the Differential Diagnosis of Breast Papillary Lesions
    Chung, Jin
    Lee, Won Kyung
    Cha, Eun-Suk
    Lee, Jee Eun
    Kim, Jeoung Hyun
    Ryu, Young Hoon
    PLOS ONE, 2016, 11 (11):
  • [7] Agreement and accuracy of shear-wave techniques (point shear-wave elastography and 2D-shear-wave elastography) using transient elastography as reference
    Fernandes, Flavia
    Piedade, Juliana
    Freitas, Gabriela
    Area, Philippe
    Santos, Ricardo
    Grinsztejn, Beatriz
    Veloso, Valdilea
    Pereira, Gustavo
    Perazzo, Hugo
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2022, 34 (08) : 873 - 881
  • [8] Stiffness of tumours measured by shear-wave elastography correlated with subtypes of breast cancer
    Chang, Jung Min
    Park, In Ae
    Lee, Su Hyun
    Kim, Won Hwa
    Bae, Min Sun
    Koo, Hye Ryoung
    Yi, Ann
    Kim, Seung Ja
    Cho, Nariya
    Moon, Woo Kyung
    EUROPEAN RADIOLOGY, 2013, 23 (09) : 2450 - 2458
  • [9] Greater Muscle Stiffness during Contraction at Menstruation as Measured by Shear-Wave Elastography
    Ham, Seoungho
    Kim, Sujin
    Choi, Hwanseong
    Lee, Youngjin
    Lee, Haneul
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2020, 250 (04): : 207 - 213
  • [10] Stiffness of tumours measured by shear-wave elastography correlated with subtypes of breast cancer
    Jung Min Chang
    In Ae Park
    Su Hyun Lee
    Won Hwa Kim
    Min Sun Bae
    Hye Ryoung Koo
    Ann Yi
    Seung Ja Kim
    Nariya Cho
    Woo Kyung Moon
    European Radiology, 2013, 23 : 2450 - 2458