Defects in CVD diamond films from their response as nuclear detectors

被引:0
|
作者
Marinelli, Marco [1 ]
Milani, Enrico [1 ]
Tucciarone, Aldo [1 ]
Rinati, Gianluca Verona [1 ]
机构
[1] Univ Roma Tor Vergata, Dipartimento Matemat, I-00133 Rome, Italy
关键词
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
CVD diamond films can be used to realize nuclear detectors with outstanding working capability in harsh environments. Since efficient particle detection requires high drift lengths of the carriers produced by the ionizing particle, the presence of defects severely limits the performance of these detectors. This is a major issue because the fabrication technology of CVD diamond is much less advanced than that of more conventional materials like silicon. The different kinds of defects in GVD diamond and their influence on the detector response are discussed. The connections between the microscopic structure of CVD diamond and the priming (or pumping) effect, which is widely used to increase CVD diamond detector performance, are elucidated. The analysis of the response of CVD diamond-based detectors is used to extract qualitative and quantitative information on the properties of defects limiting the free movement of charge carriers in the detector (e.g., carrier type for which the traps are active, activation energies, geometrical distribution in the film, etc.).
引用
收藏
页码:107 / 135
页数:29
相关论文
共 50 条
  • [1] CVD diamond films as photon detectors
    Galluzzi, F
    Marinelli, M
    Masotti, L
    Milani, E
    Pace, E
    Rossi, MC
    Salvatori, S
    Santoro, M
    Sciortino, S
    Rinati, GV
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3): : 423 - 425
  • [2] CVD diamond films as photon detectors
    Galluzzi, F.
    Marinelli, M.
    Masotti, L.
    Milani, E.
    Pace, E.
    Rossi, M.C.
    Salvatori, S.
    Santoro, M.
    Sciortino, S.
    Rinati, G.Verona
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 409 (1-3): : 423 - 425
  • [3] Analysis of traps in CVD diamond films through thermal depumping of nuclear detectors
    Balducci, A
    Marinelli, M
    Milani, E
    Morgada, ME
    Pucella, G
    Rodriguez, G
    Tucciarone, A
    Verona-Rinati, G
    Angelone, M
    Pillon, M
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2004, 201 (11): : 2542 - 2547
  • [4] CVD diamond detectors for nuclear and dosimetric applications
    Manfredotti, C
    DIAMOND AND RELATED MATERIALS, 2005, 14 (3-7) : 531 - 540
  • [5] Response of CVD diamond detectors to alpha radiation
    Souw, EK
    Meilunas, RJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 400 (01): : 69 - 86
  • [6] Effect of light on the performances of CVD diamond nuclear detectors
    Manfredotti, C
    Fizzotti, F
    Muzzani, P
    Polesello, P
    Vittone, E
    DIAMOND BASED COMPOSITES AND RELATED MATERIALS, 1997, 38 : 269 - 275
  • [7] About homogeneity of CVD diamond nuclear particles detectors
    Manfredotti, C
    Fizzotti, F
    Polesello, P
    Vittone, E
    Jaksic, M
    Bogdanovic, I
    Fazinic, S
    DIAMOND FOR ELECTRONIC APPLICATIONS, 1996, 416 : 193 - 198
  • [8] Impact of impurities and crystal defects on the performance of CVD diamond detectors
    Tarun, A.
    Lee, S. J.
    Yap, C. M.
    Finkelstein, K. D.
    Misra, D. S.
    DIAMOND AND RELATED MATERIALS, 2016, 63 : 169 - 174
  • [9] CVD diamond detectors
    Manfredotti, C
    Polesello, P
    Truccato, M
    Vittone, E
    Lo Giudice, A
    Fizzotti, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 410 (01): : 96 - 99
  • [10] CVD diamond detectors
    Manfredotti, C.
    Polesello, P.
    Truccato, M.
    Vittone, E.
    Lo Giudice, A.
    Fizzotti, F.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 410 (01): : 96 - 99