Sieve-based device for MALDI sample preparation. II. Instrumental parameterization

被引:8
|
作者
Cristoni, Simone [1 ,2 ]
Molin, Laura [1 ]
Crotti, Sara [3 ]
Bernardi, Luigi Rossi [4 ]
Seraglia, Roberta [3 ]
Traldi, Pietro [3 ]
机构
[1] ISB Ion Source & Biotechnol, I-20138 Milan, Italy
[2] CNR ITB, I-20090 Milan, Italy
[3] CNR ISTM, Cso Stati Uniti 4, I-35127 Padua, Italy
[4] Multimedica, I-20138 Milan, Italy
来源
JOURNAL OF MASS SPECTROMETRY | 2009年 / 44卷 / 11期
关键词
MALDI; sieve-based device; proteins; saccharides; resolution increase; MASS-SPECTROMETRY; PEPTIDES; DEPOSITION; PROTEINS;
D O I
10.1002/jms.1637
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple device effective for matrix-assisted laser desorption/ionization (MALDO sample preparation, based on the spraying of matrix/sample solution through a stainless steel sieve (sieve-based device, SBD), has been employed for the preparation of MALDI samples of peptides, polysaccharides and high molecular weight proteins. The instrumental parameters, mainly the sprayer voltage, solution and auxiliary gas flows, and distances between sprayer-sieve and sieve-MALDI sample holder have been optimized. The MALDI spectra obtained by laser irradiation of the microspots so obtained, exhibit resolution and sensitivity higher than those achieved by the commonly employed dried droplets (DD) method. Worth noting is the fact that, in contrast to what is observed in the DD method, identical spectra are obtained by irradiation of different areas of the MALDI sample, showing that by using the SBD the matrix/analyte ratio is constant over the entire surface. Copyright (C) 2009 JohnWiley & Sons, Ltd.
引用
收藏
页码:1579 / 1586
页数:8
相关论文
共 50 条
  • [1] Sieve-based device for MALDI sample preparation. III. Its power for quantitative measurements
    Molin, Laura
    Cristoni, Simone
    Seraglia, Roberta
    Traldi, Pietro
    JOURNAL OF MASS SPECTROMETRY, 2011, 46 (02): : 230 - 236
  • [2] Sieve-based device for MALDI sample preparation. I. Influence of sample deposition conditions in oligonucleotide analysis to achieve significant increases in both sensitivity and resolution
    Molin, Laura
    Cristoni, Simone
    Crotti, Sara
    Bernardi, Luigi Rossi
    Seraglia, Roberta
    Traldi, Pietro
    JOURNAL OF MASS SPECTROMETRY, 2008, 43 (11): : 1512 - 1520
  • [3] Novel approach to MALDI-TOF-MS sample preparation.
    Chen, WB
    Lee, PJ
    Vazquez, S
    Chakraborty, A
    Berger, SJ
    Finch, JW
    Gebler, JC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 226 : U113 - U113
  • [4] The proteins of grasses. II. A new method of preparation.
    Chibnall, AC
    Miller, EJ
    Hall, DH
    Westall, RG
    BIOCHEMICAL JOURNAL, 1933, 27 : 1879 - 1884
  • [5] A novel sample preparation device for MALDI-MS
    Dwyer, J
    Botten, D
    AMERICAN LABORATORY, 1996, 28 (17) : 51 - &
  • [6] Preparation and application of monolithic molecular sieve-based catalysts in microwave catalytic combustion of VOCs
    Liu, Shuang
    Bo, Long-Li
    Ning, Ke
    Zhang, Ting-Ting
    Liu, Jia-Dong
    Zhongguo Huanjing Kexue/China Environmental Science, 2020, 40 (11): : 4688 - 4696
  • [7] Constructing molecular sieve-based MOFs nanofiber composites for separating Co(II) from wastewater
    Pan, Ting
    Chen, Chuang
    Yu, Li
    Yin, Cong
    Zhou, Mi
    Qiu, Huidong
    Yuan, Guoyuan
    Xiong, Wei
    Pu, Xiaoqin
    SURFACES AND INTERFACES, 2024, 52
  • [8] Enhanced Ni(II) Removal from Wastewater Using Novel Molecular Sieve-Based Composites
    Li, Zengjie
    Lei, Yalin
    Dong, Li
    Yu, Li
    Yin, Cong
    MATERIALS, 2024, 17 (13)
  • [9] Sample preparation for MALDI mass spectrometry using an elastomeric device reversibly sealed on the MALDI target
    Chen, Xiaoxi
    Murawski, Anthony
    Kuang, Guannan
    Sexton, Daniel J.
    Galbraith, William
    ANALYTICAL CHEMISTRY, 2006, 78 (17) : 6160 - 6168
  • [10] A microfluidic electrocapture device in sample preparation for protein analysis by MALDI mass spectrometry
    Astorga-Wells, J
    Jörnvall, H
    Bergman, T