Artificial iris exchange

被引:2
|
作者
Bahadur, Gavin G. [1 ]
Miller, Kevin M. [1 ]
机构
[1] Univ Calif Los Angeles, David Geffen Sch Med, Stein Eye Inst, Dept Ophthalmol, Los Angeles, CA 90095 USA
来源
关键词
DIAPHRAGM INTRAOCULAR-LENS; COMPLICATIONS; IMPLANTATION; DEFECTS; EYES; EFFICACY; OUTCOMES; SAFETY;
D O I
10.1097/j.jcrs.0000000000000321
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe the indications, motivations, and outcomes of artificial iris exchange. Setting: Stein Eye Institute. Design: Consecutive case series. Methods: Review of medical records of patients implanted with an artificial iris device who underwent a subsequent artificial iris exchange. Results: Five patients were identified: 4 women and 1 man. Their ages ranged from 19 to 58 years at the time of the exchange. One patient had congenital aniridia; the other 4 had acquired iris defects. Three exchanges were simultaneous; 2 were consecutive. Corneal decompensation was the most common indication for the surgery precipitating the exchange. Explanted iris devices included models from Ophtec, Morcher, BrightOcular, and HumanOptics. Replacement models were from Morcher and HumanOptics. Three of the original irides were passively fixated in the capsular bag or ciliary sulcus. All of the replacement irides were suture-fixated to the sclera, either directly or secondarily by way of an intraocular lens. The motivation for the exchange was improved cosmesis in 4 patients and sustained cosmesis in 1 patient. Final visual acuities were 20/25 for 2 patients, 20/100 for 1 patient, and hand motion for 2 patients. Conclusions: No 2 iris exchanges were similar. Clinical indications and outcomes varied considerably from patient to patient. A common thread was each patient's motivation to maintain or improve on the functional and cosmetic benefits of having been previously implanted with an artificial iris device. Final visual acuity results were often poor because of the effects of comorbidities, especially glaucoma and corneal decompensation. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS.
引用
收藏
页码:1630 / 1636
页数:7
相关论文
共 50 条
  • [1] Artificial iris
    Szurman, P.
    Jaissle, G.
    OPHTHALMOLOGE, 2011, 108 (08): : 720 - 727
  • [2] Artificial iris rings
    A K K Chung
    Eye, 2008, 22 : 1203 - 1204
  • [3] Artificial iris rings
    Chung, A. K. K.
    EYE, 2008, 22 (09) : 1203 - 1204
  • [4] Artificial iris intraocular tenses in aniridia or iris deficiencies
    Roman, S.
    Cherrate, H.
    Trouvet, J. P.
    Ullern, M.
    Baudouin, C.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2009, 32 (05): : 320 - 325
  • [5] Surgical treatment with an artificial iris
    Mayer, C. S.
    Hoffmann, A. E.
    OPHTHALMOLOGE, 2015, 112 (10): : 865 - 868
  • [6] Artificial iris polymerized by microwave
    López, FU
    Azambuja, T
    Bercini, F
    Fortes, CB
    Samuels, SMW
    Montagner, A
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B83 - B83
  • [7] Pupil reconstruction with an artificial iris
    Mayer, Christian
    Khoramnia, Ramin
    OPHTHALMOLOGE, 2022, 119 (01): : 3 - 12
  • [8] Saying aye to the artificial iris
    Nature Biotechnology, 2018, 36 : 565 - 565
  • [9] Saying aye to the artificial iris
    不详
    NATURE BIOTECHNOLOGY, 2018, 36 (07) : 565 - 565
  • [10] Artificial iris: state of the art
    Gius, Irene
    Tozzi, Luigi
    De Biasi, Chiara Sofia
    Pizzolon, Tobia
    Parolini, Barbara
    Frisina, Rino
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (04): : 430 - 437