Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer

被引:345
|
作者
Kotecha, Aachal
Elsheikh, Ahmed
Roberts, Cynthia R.
Zhu, Haogang
Garway-Heath, David F.
机构
[1] Moorfields Eye Hosp, Glaucoma Res Unit, London EC1V 2PD, England
[2] City Univ London, Dept Optometry & Visual Sci, London EC1V 0HB, England
[3] Univ Dundee, Div Civil Engn, Dundee, Scotland
[4] Ohio State Univ, Dept Ophthalmol, Columbus, OH 43210 USA
[5] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
关键词
D O I
10.1167/iovs.06-0557
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The Ocular Response Analyzer ( ORA) is a new instrument that measures the corneal biomechanical response ( corneal hysteresis, CH) to rapid indentation by an air jet. CH is the difference in applanation pressures (P1, P2) between the rising and falling phases of the air jet. The investigation had two parts: a characterization study and a validation study. In the characterization study, the purposes were to investigate the intraocular pressure (IOP)-dependence of CH and to characterize the performance of the ORA. In the validation study, the purposes were to investigate the association between CH and both age and central corneal thickness (CCT) and the agreement between ORA and Goldmann applanation tonometer ( GAT) IOP measurements. METHODS. For the characterization study, data were collected from 105 untreated subjects ( 45 ocular hypertensive patients and 60 normal subjects; mean age, 60 years, range, 26 - 82). GAT and ORA measurements were performed before and after IOP lowering of one randomly selected eye with apraclonidine drops. The change in P1 and P2 ( arbitrary units) in relation to change in GAT IOP was analyzed to calibrate the instrument. The relation between P1, P2, and CCT was explored and ORA IOP was derived from the analyses. For the validation study, ORA and GAT IOP and CCT were measured in 144 eyes of 144 untreated subjects ( mean age, 58 years; range, 19 - 83). The characterization calculations were applied to the dataset and values of CH and ORA IOP were calculated. The relationship between CH and both subject age and CCT was determined. The associations between CH and CCT and between ORA and GAT IOPs, were investigated by linear regression analysis. The agreement between measuring devices was calculated. RESULTS. In the characterization study, P1 changed by 6.41 arbitrary units for every 1-mm Hg change in GAT IOP. CH ( P1-P2) changed by -1.60 arbitrary units for every 1-mm Hg change in GAT IOP. For each unit change in P2, P1 changed by 1.27 units. From this association a new IOP-independent corneal factor was derived [ P1 - ( P2/ 1.27)] and is termed the corneal constant factor (CCF; mm Hg). ORA IOP normalized for CCF was defined as P2 - CCF ( mm Hg). The CCF ( mm Hg) was associated with CCT ( micrometers) and with age: CCF = [(0.036 center dot CCT) - (0.028 center dot age)] + 1.06 ( adjusted r(2) = 0.34; P < 0.0001 for CCT, P = 0.007 for age). Normalized ORA IOP measurements were not associated with CCT. GAT IOP was associated with CCT and CCF - more strongly with the latter: GAT IOP = ( 0.03 center dot CCT) + 1.52 ( r(2)=0.06, P=0.002); GAT IOP = (0.65 center dot CCF) + 4.5 (r(2)=0.13, P < 0.0001). The mean difference (95% limits of agreement) between GAT and normalized ORA IOP was 0.1 (-6.6 to +6.8) mm Hg. CONCLUSIONS. The CCF describes an IOP-independent biomechanical property of the cornea that increases with thicker CCT and decreases with greater age. It is moderately strongly associated with CCT and yet explains more of the interindividual variation in GAT IOP than does CCT. Normalized ORA IOP measurements are not associated with CCT.
引用
收藏
页码:5337 / 5347
页数:11
相关论文
共 50 条
  • [1] Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer
    Oddone, F
    Kotecha, A
    Shewry, J
    White, ET
    Garway-Heath, DF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [2] Biomechanical properties of the cornea measured by the Ocular Response Analyzer and their association with intraocular pressure and the central corneal curvature
    Franco, Sandra
    Lira, Madalena
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2009, 92 (06) : 469 - 475
  • [3] Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients
    Sen, Emine
    Tutuncu, Yasemin
    Balikoglu-Yilmaz, Melike
    Elgin, Ufuk
    Berker, Dilek
    Ozturk, Faruk
    Guler, Serdar
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (08) : 1283 - 1288
  • [4] Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients
    Emine Sen
    Yasemin Tutuncu
    Melike Balikoglu-Yilmaz
    Ufuk Elgin
    Dilek Berker
    Faruk Ozturk
    Serdar Guler
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 1283 - 1288
  • [5] Identification of Biomechanical Properties of the Cornea: The Ocular Response Analyzer
    Terai, Naim
    Raiskup, Frederik
    Haustein, Michael
    Pillunat, Lutz E.
    Spoerl, Eberhard
    CURRENT EYE RESEARCH, 2012, 37 (07) : 553 - 562
  • [6] Evaluation of Corneal Biomechanical Properties Measured by Ocular Response Analyzer in Eyes with Pterygium
    Kara, Necip
    Baz, Okkes
    Bozkurt, Ercument
    Yazici, Ahmet Taylan
    Demirok, Ahmet
    Yilmaz, Omer Faruk
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (02): : 94 - 97
  • [7] Biomechanical parameters of the cornea measured with the Ocular Response Analyzer in normal eyes
    Kotecha, Aachal
    Russell, Richard A.
    Sinapis, Angelos
    Pourjavan, Sayeh
    Sinapis, Dimitros
    Garway-Heath, David F.
    BMC OPHTHALMOLOGY, 2014, 14
  • [8] Biomechanical parameters of the cornea measured with the Ocular Response Analyzer in normal eyes
    Aachal Kotecha
    Richard A Russell
    Angelos Sinapis
    Sayeh Pourjavan
    Dimitros Sinapis
    David F Garway-Heath
    BMC Ophthalmology, 14
  • [9] Evaluation of Corneal Biomechanical Properties Measured By Ocular Response Analyzer in Cases with Rheumatoid Arthritis
    Altinkaynak, Hasan
    Kara, Necip
    Baz, Okkes
    Celik, Yonca Cagatay
    Bozkurt, Ercument
    Yazici, Ahmet Taylan
    Demirok, Ahmet
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (03): : 167 - 170
  • [10] Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    Luce, DA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01): : 156 - 162