Depth of interaction measurement in gamma ray imaging detectors with continuous scintillation crystals

被引:0
|
作者
Lerche, CW [1 ]
Benlloch, JM [1 ]
Sánchez, F [1 ]
Pavón, N [1 ]
Gimenez, EN [1 ]
Giménez, M [1 ]
Fernández, M [1 ]
Cerdá, J [1 ]
Martinez, J [1 ]
Sebastià, A [1 ]
机构
[1] UV, CSIC, Inst Fis Corpuscular, Valencia, Spain
关键词
depth of interaction; continuous scintillator; anger logic;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A design for an inexpensive depth of interaction (DOI) detector for gamma rays, suitable for nuclear medical applications, especially positron emission tomography (PET), has been developed, studied by simulations and tested experimentally. The detector consists of a continuous LSO-scintillator of dimensions 42x42x10 mm(3) and a new compact large-area (49x49 mm(2)) position sensitive photo-multiplier (PSPMT) H8500 from Hamamatsu. Since a continuous crystal is used, the scintillation light distribution is not destroyed and its first 3 moments can be used to determine the energy (0th moment), the centroids along the x- and y-direction (1st moments) and the depth of interaction (DOI), which is strongly correlated to the distribution's width and thus its standard deviation (2nd moment). The simultaneous computation of these moments allows a three-dimensional reconstruction of the position of interaction of the gamma-rays within the scintillating crystal and will be realized by a modified position sensitive proportional (PSP) resistor network. No additional photo detectors or scintillating crystals are needed. According to previous Monte Carlo simulations which estimated the influence of Compton scattering for 511 keV gamma-rays, the transport of the scintillation light within the detector assembly and also the behavior of the modified PSP resistor network, we expect a spatial resolution of less than or similar to 2 mm and a DOI resolution of approximate to 5 mm. The first experimental results presented here yield an intrinsic spatial resolution of less than or similar to 1.8 mm and 2.6 mm for the x- and y-direction respectively and a DOI resolution less than or similar to 1 cm. Further we measured an energy resolution of 12%-18%.
引用
收藏
页码:2169 / 2173
页数:5
相关论文
共 50 条
  • [1] Maximum likelihood positioning for gamma-ray imaging detectors with depth of interaction measurement
    Lerche, Ch. W.
    Ros, A.
    Monzo, J. M.
    Aliaga, R. J.
    Ferrando, N.
    Martinez, J. D.
    Herrero, V.
    Esteve, R.
    Gadea, R.
    Colom, R. J.
    Toledo, J.
    Mateo, F.
    Sebastia, A.
    Sanchez, F.
    Benlloch, J. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 604 (1-2): : 359 - 362
  • [2] Lanthanum scintillation crystals for gamma ray imaging
    Pani, R.
    Bennati, P.
    Betti, M.
    Cinti, M. N.
    Pellegrini, R.
    Mattioli, M.
    Cencelli, V. Orsolini
    Navarria, F.
    Bollini, D.
    Moschini, G.
    Garibaldi, F.
    de Notaristefani, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 567 (01): : 294 - 297
  • [3] Depth of γ-ray interaction within continuous crystals from the width of its scintillation light-distribution
    Lerche, CW
    Benlloch, JM
    Sánchez, F
    Pavón, N
    Escat, B
    Gimenez, EN
    Fernández, M
    Torres, I
    Giménez, M
    Sebastià, A
    Martínez, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 560 - 572
  • [4] Photodetector and scintillation crystals requirements for gamma-ray imaging
    Pani, R.
    Cinti, M. N.
    Pellegrini, R.
    Bennati, P.
    Lo Meo, S.
    Ridolfi, S.
    Vittorini, F.
    De Notaristefani, F.
    Mattioli, M.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2007, 30 (05): : 435 - 448
  • [5] Photodetector and scintillation crystals requirements for gamma-ray imaging
    Pani, R.
    Cinti, M. N.
    Pellegrini, R.
    Bennati, P.
    Lo Meo, S.
    Ridolfi, S.
    Vittorini, F.
    De Notaristefani, F.
    Mattioli, M.
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA C-COLLOQUIA ON PHYSICS, 2007, 30 (05): : 435 - 448
  • [6] Retroreflector arrays for better light collection efficiency of γ-ray imaging detectors with continuous scintillation crystals without DOI misestimation
    Ros, A.
    Lerche, Ch. W.
    Sebastia, A.
    Sanchez, F.
    Benlloch, J. M.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [7] Simulation and measurement of gamma ray and annihilation photon imaging detectors
    Habte, F
    Olcott, PD
    Foudray, AMK
    Levin, CS
    Zhang, J
    Chinn, G
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4019 - 4022
  • [8] ELECTRON AND GAMMA-RAY SPECTROSCOPY WITH SCINTILLATION DETECTORS
    BANNERMAN, RC
    LEWIS, GM
    CURRAN, SC
    PHILOSOPHICAL MAGAZINE, 1951, 42 (333): : 1097 - 1112
  • [9] Thick monolithic scintillation crystals for TOF-PET with depth-of-interaction measurement
    Vinke, Ruud
    van Dam, Herman T.
    Seifert, Stefan
    Beekman, Freek J.
    Lohner, Herbert
    Schaart, Dennis R.
    Dendooven, Peter
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1981 - 1984
  • [10] Deep Learning Techniques for Gamma Ray Interaction Location Estimation in Monolithic Scintillation Crystal Detectors
    Tao, Li
    Li, Xin
    Furenlid, Lars R.
    Levin, Craig S.
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,