Endocan removal during continuous renal replacement therapy: does it affect the reliability of this biomarker?

被引:3
|
作者
Honore, Patrick M. [1 ]
De Bels, David [1 ]
Attou, Rachid [1 ]
Redant, Sebastien [1 ]
Gallerani, Andrea [1 ]
Kashani, Kianoush [2 ]
机构
[1] Ctr Hosp Univ Brugmann, ICU Dept, Pl Van Gehuchtenpl 4, B-1020 Brussels, Belgium
[2] Mayo Clin, Div Pulm & Crit Care Med, Div Nephrol & Hypertens, Rochester, MN USA
来源
CRITICAL CARE | 2019年 / 23卷
关键词
D O I
10.1186/s13054-019-2469-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Endocan removal during continuous renal replacement therapy: does it affect the reliability of this biomarker?
    Patrick M. Honore
    David De Bels
    Rachid Attou
    Sebastien Redant
    Andrea Gallerani
    Kianoush Kashani
    Critical Care, 23
  • [2] Endocan is a reliable biomarker during continuous renal replacement therapy
    Hureau, Maxence
    Gaudet, Alexandre
    Caires, Nathalie De Freitas
    Parmentier, Erika
    Poissy, Julien
    Duburcq, Thibault
    Lassalle, Philippe
    Mathieu, Daniel
    CRITICAL CARE, 2019, 23 (01):
  • [3] Endocan is a reliable biomarker during continuous renal replacement therapy
    Maxence Hureau
    Alexandre Gaudet
    Nathalie De Freitas Caires
    Erika Parmentier
    Julien Poissy
    Thibault Duburcq
    Philippe Lassalle
    Daniel Mathieu
    Critical Care, 23
  • [4] Hepcidin Removal during Continuous Renal Replacement Therapy
    Colbert, James F.
    Griffin, Benjamin R.
    Rolloff, Kristy
    Erzen, Christopher L.
    Haeger, Sarah M.
    Altmann, Chris
    Okamura, Kayo
    Campbell, Ruth
    Teitelbaum, Isaac
    Faubel, Sarah
    BLOOD PURIFICATION, 2024, 53 (01) : 23 - 29
  • [5] Prone positioning does not affect cannula function during extracorporeal membrane oxygenation or continuous renal replacement therapy
    Goettler, CE
    Pryor, JP
    Hoey, BA
    Phillips, JK
    Balas, MC
    Shapiro, MB
    CRITICAL CARE, 2002, 6 (05): : 452 - 455
  • [6] Prone positioning does not affect cannula function during extracorporeal membrane oxygenation or continuous renal replacement therapy
    Claudia E Goettler
    John P Pryor
    Brian A Hoey
    JoAnne K Phillips
    Michelle C Balas
    Michael B Shapiro
    Critical Care, 6
  • [7] How Does Continuous Renal Replacement Therapy Affect Septic Acute Kidney Injury?
    Zhang, Jingxiao
    Tian, Jiakun
    Sun, Hongzhi
    Digvijay, Kumar
    Neri, Mauro
    Bhargava, Vinant
    Yin, Yongjie
    Ronco, Claudio
    BLOOD PURIFICATION, 2018, 46 (04) : 326 - 331
  • [8] Extracorporeal Carbon Dioxide Removal During Continuous Renal Replacement Therapy as Adjunctive Therapy
    Jacobs, Rita
    Sablon, Adriaan
    Spapen, Herbert
    RESPIRATORY CARE, 2020, 65 (04) : 517 - 524
  • [9] Possible removal of topiramate by continuous renal replacement therapy
    Browning, Linda
    Parker, Dennis, Jr.
    Liu-DeRyke, Xi
    Shah, Aashit
    Coplin, William M.
    Rhoney, Denise H.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2010, 288 (1-2) : 186 - 189
  • [10] DRUG REMOVAL DURING CONTINUOUS RENAL REPLACEMENT THERAPIES
    GOLPER, TA
    DIALYSIS & TRANSPLANTATION, 1993, 22 (04) : 185 - &