Automatic contour propagation in cine cardiac magnetic resonance images

被引:69
|
作者
Hautvast, Gilion [1 ]
Lobregt, Steven
Breeuwer, Marcel
Gerritsen, Frans
机构
[1] Philips Med Syst Healthcare Informat, Adv Dev Dept, NL-5680 DA Best, Netherlands
[2] Tech Univ Eindhoven, Biomed Image Anal Grp, NL-5600 MB Eindhoven, Netherlands
关键词
active contours; cardiac magnetic resonance imaging (MRI); propagation;
D O I
10.1109/TMI.2006.882124
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We have developed a method for automatic contour propagation in cine cardiac magnetic resonance images. The method consists of a new active contour model that tries to maintain a constant contour environment by matching gray values in profiles perpendicular to the contour. Consequently, the contours should maintain a constant position with respect to neighboring anatomical structures, such that the resulting contours reflect the preferences of the user. This is particularly important in cine cardiac magnetic resonance images because local image features do not describe the desired contours near the papillary muscle. The accuracy of the propagation result is influenced by several parameters. Because the optimal setting of these parameters is application dependent, we describe how to use full factorial experiments to optimize the parameter setting. We have applied our method to cine cardiac magnetic resonance image sequences from the long axis two-chamber view, the long axis four-chamber view, and the short axis view. We performed our optimization procedure for each contour in each view. Next, we performed an extensive clinical validation of our method on 69 short axis data sets and 38 long axis data sets. In the optimal parameter setting, our propagation method proved to be fast, robust, and accurate. The resulting cardiac contours are positioned within the interobserver ranges of manual segmentation. Consequently, the resulting contours can be used to accurately determine physiological parameters such as stroke volume and ejection fraction.
引用
收藏
页码:1472 / 1482
页数:11
相关论文
共 50 条
  • [1] Automatic cardiac contour propagation in short axis cardiac MR images
    Hautvast, GLTF
    Breeuwer, M
    Lobregt, S
    Vilanova, A
    Gerritsen, FA
    CARS 2005: Computer Assisted Radiology and Surgery, 2005, 1281 : 351 - 356
  • [2] An automatic contour extraction algorithm for short-axis cardiac magnetic resonance images
    Zimmer, Y
    Akselrod, S
    MEDICAL PHYSICS, 1996, 23 (08) : 1371 - 1379
  • [3] Registration and segmentation of cine and late enhancement cardiac magnetic resonance images
    Gilion Hautvast
    Cybele Ciofolo-Veit
    Marcel Breeuwer
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [4] Correction of motion artifacts from cardiac cine magnetic resonance images
    Lötjönen, J
    Pollari, M
    Kivistö, S
    Lauerma, K
    ACADEMIC RADIOLOGY, 2005, 12 (10) : 1273 - 1284
  • [5] Automatic right ventricular segmentation for cine cardiac magnetic resonance images based on a new deep atlas network
    Wang, Lijia
    Su, Hanlu
    Liu, Peng
    MEDICAL PHYSICS, 2023, 50 (11) : 7060 - 7070
  • [6] A New Approach for Automatic Identification of the Ventricular Boundary in Cine Magnetic Resonance Images
    Wang, Zhenzhou
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (05) : 1139 - 1154
  • [7] Accurate Automatic Analysis of Cardiac Cine Images
    Khalifa, Fahmi
    Beache, Garth M.
    Gimel'farb, Georgy
    Giridharan, Guruprasad A.
    El-Baz, Ayman
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (02) : 445 - 455
  • [8] Quantification of the severity of tricuspid regurgitation from cardiac magnetic resonance cine images
    Diego Medvedofsky
    Javier Leon Jimenez
    Karima Addetia
    Roberto Lang
    Victor Mor-Avi
    Amit R Patel
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [9] Semi-automatic segmentation of non-viable cardiac tissue using cine and delayed enhancement magnetic resonance images
    O'Donnell, T
    Xu, N
    Setser, R
    White, RD
    MEDICAL IMAGING 2003: PHYSIOLOGY AND FUNCTION: METHODS, SYSTEMS, AND APPLICATIONS, 2003, 5031 : 242 - 251
  • [10] AUTOMATIC MYOCARDIAL CONTOUR-DETECTION OF CINE COMPUTED TOMOGRAPHIC-IMAGES
    PHILIP, KP
    DOVE, EL
    GOTTEINER, NL
    VONESH, MJ
    REED, JE
    RUMBERGER, JA
    STANFORD, W
    CHANDRAN, KB
    MCPHERSON, DD
    CLINICAL RESEARCH, 1991, 39 (03): : A694 - A694