Analysis of total corneal astigmatism with a rotating Scheimpflug camera in keratoconus

被引:5
|
作者
Kim, Jinho [1 ]
Whang, Woong-Joo [2 ]
Kim, Hyun-Seung [1 ]
机构
[1] Catholic Univ Korea Korea, Seoul St Marys Hosp, Dept Ophthalmol, Coll Med, Seoul, South Korea
[2] Catholic Univ Korea, Yeouido St Marys Hosp, Coll Med, Dept Ophthalmol, Seoul, South Korea
关键词
CATARACT-SURGERY; ANTERIOR; POWER; SHAPE; EYES; SURFACE; ERROR;
D O I
10.1186/s12886-020-01747-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To analyze mean corneal powers and astigmatisms on anterior, posterior, and total cornea in patients with keratoconus as calculated according to various keratometric measurements using a Scheimpflug camera. Methods: We examined the left eyes of 64 patients (41 males and 23 females; mean age 29.94 +/- 6.63 years) with keratoconus. We measured simulated K (Sim-K), posterior K, true net power (TNP) and four types of total corneal refractive powers (TCRP). We then used the obtained values to analyze mean K, and corneal astigmatism. TCRP were measured at 2.0 +/- 5.0 mm. Results: Mean corneal powers from Sim K, posterior K, and TNP were 49.12 +/- 3.99, - 7.39 +/- 0.79, and 47.78 +/- 4.09 diopters, respectively. For TCRP centered on the pupil, mean K tended to decrease with measurement area (all p < 0.01). While, both mean K and astigmatism measured using TCRP centered on the apex decreased with measurement area (all p < 0.001). TCRP centered on the apex were greater than those centered on the pupil for mean K values calculated using TCRP (all p < 0.001). The proportion of WTR was greatest on the anterior and total cornea. As the measurement area moved to the periphery, the proportion of WTR increased. Conclusions: Mean corneal powers and astigmatisms on total cornea with keratoconus change depending on calculation methods and measurement areas.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Analysis of total corneal astigmatism with a rotating Scheimpflug camera in keratoconus
    Jinho Kim
    Woong-Joo Whang
    Hyun-Seung Kim
    BMC Ophthalmology, 20
  • [2] Total Corneal Astigmatism Measurements: Agreement Between 2 Rotating Scheimpflug Cameras
    Savini, Giacomo
    Noeser, Kristian
    Schiano-Lomoriello, Domenico
    Ducoli, Pietro
    CORNEA, 2017, 36 (04) : 463 - 469
  • [3] Influence of Posterior Corneal Astigmatism on Total Corneal Astigmatism in Eyes With Keratoconus
    Savini, Giacomo
    Naeser, Kristian
    Schiano-Lomoriello, Domenico
    Mularoni, Alessandro
    CORNEA, 2016, 35 (11) : 1427 - 1433
  • [4] Screening of Keratoconus and Keratoconus Suspects Using Rotating Scheimpflug Corneal Topography
    Shimabukuro, M.
    Higashiura, R.
    Fuchihata, M.
    Nakagawa, T.
    Koh, S.
    Inoue, T.
    Maeda, N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [5] Corneal powers measured with a rotating Scheimpflug camera
    Naeser, Kristian
    Savini, Giacomo
    Bregnhoj, Jesper Flethoj
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (09) : 1196 - 1200
  • [6] Reproductivity and repeatability of central corneal thickness measurement in keratoconus using the rotating scheimpflug camera and ultrasound pachymetry
    De Sanctis, Ugo
    Missolungi, Alessandro
    Mutani, Bernardo
    Richiardi, Lorenzo
    Grignolo, Federico M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (05) : 712 - 718
  • [7] The role of reference body selection in calculating posterior corneal elevation and prediction of keratoconus using rotating Scheimpflug camera
    Kovacs, Illes
    Mihaltz, Kata
    Ecsedy, Monika
    Nemeth, Janos
    Nagy, Zoltan Z.
    ACTA OPHTHALMOLOGICA, 2011, 89 (03) : e251 - e256
  • [8] International values of corneal elevation in normal subjects by rotating Scheimpflug camera
    Feng, Matthew T.
    Belin, Michael W.
    Ambrosio, Renato, Jr.
    Grewal, Satinder P. S.
    Yan, Wang
    Shaheen, Mohamed Shafik
    Jordon, Charlotte A.
    McGhee, Charles
    Maeda, Naoyuki
    Neuhann, Tobias H.
    Dick, H. Burkhard
    Steinmueller, Andreas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (10): : 1817 - 1821
  • [9] Corneal power changes with Scheimpflug rotating camera after hyperopic LASIK
    Whang, Woong-Joo
    Yoo, Young-Sik
    Joo, Choun-Ki
    MEDICINE, 2018, 97 (50)
  • [10] Comparing Changes in Corneal Astigmatism Using Scheimpflug Camera after Epiblepharon Correction Surgery
    Lee, Ji Hye
    Kim, Sung Eun
    Byun, Yong-Soo
    Yang, Suk-Woo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (03): : 221 - 227