Biological dosimetry after a criticality accident

被引:0
|
作者
Fatome, M
Agay, D
Martin, S
Mestries, JC
Multon, E
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the case of a criticality accident, there are two radiation components, i.e. neutron and gamma, and the exposure is heterogeneous. The available techniques are biophysical techniques, which can give data about the dose distribution and the neutron component dose, classical techniques (electroencephalography, lymphocytes counting, dicentric and acentric fragments counting, biochemical indicators) which can give an estimation of the mean biological dose, new biochemical parameters which are good indicators of vital prognosis and new cytogenetic techniques under study. Biological dosimetry or rather research of biological indicators of irradiation remains difficult, particularly because of the heterogeneity of exposure. A multiparametric determination seems the only solution.
引用
收藏
页码:455 / 459
页数:5
相关论文
共 50 条
  • [1] Chromosome aberrations scoring for biological dosimetry in a criticality accident
    Voisin, P
    Lloyd, D
    Edwards, A
    RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 467 - 470
  • [2] NUCLEAR-ACCIDENT DOSIMETRY IN A SIMULATED CRITICALITY ACCIDENT
    SANTORO, RT
    AFFEL, RG
    CAIN, GC
    GREENE, JH
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1974, 19 (OCT27): : 195 - 196
  • [3] Criticality accident dosimetry with ESR spectroscopy
    DErrico, F
    Fattibene, P
    Onori, S
    Pantaloni, M
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) : 1335 - 1339
  • [4] Criticality accident dosimetry by chromosomal analysis
    Voisin, P
    Roy, L
    Hone, PA
    Edwards, AA
    Lloyd, DC
    Stephan, G
    Romm, H
    Groer, PG
    Brame, R
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 443 - 447
  • [5] BIOLOGICAL AND PHYSICAL DOSIMETRY AFTER A RADIATION ACCIDENT
    DOLPHIN, GW
    BOLTON, D
    HUMPHREY.DL
    SPEIGHT, DL
    STRADLIN.GN
    NATURE, 1970, 227 (5254) : 165 - &
  • [6] INTERCOMPARISON OF CRITICALITY ACCIDENT DOSIMETRY SYSTEMS
    GREENE, RT
    SWAJA, RE
    HEALTH PHYSICS, 1983, 45 (01): : 191 - 191
  • [7] PERFORMANCE OF NUCLEAR CRITICALITY ACCIDENT DOSIMETRY SYSTEMS
    SWAJA, RE
    SIMS, CS
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1981, 38 (JUN): : 586 - 587
  • [8] International intercomparison for criticality dosimetry:: The case of biological dosimetry
    Roy, L
    Buard, V
    Delbos, M
    Durand, V
    Paillole, N
    Grégoire, E
    Voisin, P
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 471 - 476
  • [9] Criticality accident dosimetry: An international intercomparison at the SILENE reactor
    Medioni, R
    Delafield, HJ
    RADIATION PROTECTION DOSIMETRY, 1997, 70 (1-4) : 445 - 454
  • [10] Bayesian methods for chromosome dosimetry following a criticality accident
    Brame, RS
    Groer, PG
    RADIATION PROTECTION DOSIMETRY, 2003, 104 (01) : 61 - 63