Probehead operating at 35 GHz for continuous wave and pulse electron paramagnetic resonance applications

被引:14
|
作者
Gromov, Igor [1 ]
Forrer, Jorg [1 ]
Schweiger, Arthur [1 ]
机构
[1] ETH, Phys Chem Lab, CH-8093 Zurich, Switzerland
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2006年 / 77卷 / 06期
关键词
D O I
10.1063/1.2216849
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The design, construction, numerical modeling, and performance of a probehead for electron paramagnetic resonance (EPR) spectroscopy at 34-36 GHz is described. A classical cylindrical cavity operating in the TE011 mode with adjustable frequency and coupling has been found to be well suited for continuous wave and pulse EPR studies of frozen solutions of transition metal complexes at low temperature. The highest attention is given to the probehead performance in the pulse mode. The implemented design has been analyzed in detail using numerical modeling. The distribution of the electromagnetic fields, eigenfrequencies, quality factors, coupling coefficients, and conversion factors are calculated and compared with experimental data. The results demonstrate the effectiveness of the design and can serve as a guide for probehead optimization. (c) 2006 American Institute of Physics.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Cryogenic Q-band (35 GHz) probehead featuring large excitation microwave fields for pulse and continuous wave electron paramagnetic resonance spectroscopy:: Performance and applications
    Forrer, Joerg
    Garcia-Rubio, Ines
    Schuhmam, Rolf
    Tschaggelar, Rene
    Harmer, Jeffrey
    JOURNAL OF MAGNETIC RESONANCE, 2008, 190 (02) : 280 - 291
  • [2] A 1-2 GHz pulsed and continuous wave electron paramagnetic resonance spectrometer
    Quine, RW
    Rinard, GA
    Ghim, BT
    Eaton, SS
    Eaton, GR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (07): : 2514 - 2527
  • [3] Cryogenic 35 GHz pulse ENDOR probehead accommodating large sample sizes: Performance and applications
    Tschaggelar, Rene
    Kasumaj, Besnik
    Santangelo, Maria Grazia
    Forrer, Joerg
    Leger, Patrik
    Dube, Henry
    Diederich, Francois
    Harmer, Jeffrey
    Schuhmann, Rolf
    Garcia-Rubio, Ines
    Jeschke, Gunnar
    JOURNAL OF MAGNETIC RESONANCE, 2009, 200 (01) : 81 - 87
  • [4] A continuous-wave and pulsed electron spin resonance spectrometer operating at 275 GHz
    Blok, H
    Disselhorst, JAJM
    Orlinskii, SB
    Schmidt, J
    JOURNAL OF MAGNETIC RESONANCE, 2004, 166 (01) : 92 - 99
  • [5] The continuous wave electron paramagnetic resonance experiment revisited
    Kälin, M
    Gromov, I
    Schweiger, A
    JOURNAL OF MAGNETIC RESONANCE, 2003, 160 (02) : 166 - 182
  • [6] A continuous wave and pulse electron paramagnetic resonance study of Co(II) (tetraphenylporphyrin) in different matrices
    Van Doorslaer, S
    Schweiger, A
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2001, 3 (02) : 159 - 166
  • [7] Design and Implementation of Integrated Dual-Mode Pulse and Continuous-Wave Electron Paramagnetic Resonance Spectrometers
    Sun, Jui-Hung
    Wu, Difei
    Qin, Peter
    Sideris, Constantine
    IEEE Transactions on Biomedical Circuits and Systems, 2024, 18 (06) : 1209 - 1219
  • [8] Decoupling of automatic control systems in a continuous-wave electron paramagnetic resonance spectrometer for biomedical applications
    Hirata, H
    Watanabe, H
    Kumada, M
    Itoh, K
    Fujii, H
    NMR IN BIOMEDICINE, 2004, 17 (05) : 295 - 302
  • [9] Continuous wave electron paramagnetic resonance of nitroxide biradicals in fluid solution
    Eaton, Sandra S.
    Woodcock, Lukas B.
    Eaton, Gareth R.
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2018, 47A (02)
  • [10] A pulsed and continuous wave 250 MHz electron paramagnetic resonance spectrometer
    Ouine, RW
    Rinard, GA
    Eaton, SS
    Eaton, GR
    CONCEPTS IN MAGNETIC RESONANCE, 2002, 15 (01): : 59 - 91