Pathologic fracture of the distal femur in total knee arthroplasty. Polyethylene-wear-induced osteolysis? - a case report

被引:1
|
作者
Napp, M. [1 ]
Frank, M. [2 ]
Witt, M. [1 ]
机构
[1] Mediclin Klinikum Plau See, Klin Orthopad Unfall & Handchirurg, D-19395 Plau Am See, Germany
[2] Ernst Moritz Arndt Univ Greifswald, Abt Unfall & Wiederherstellungschirurg, D-17487 Greifswald, Germany
来源
ORTHOPADE | 2009年 / 38卷 / 10期
关键词
Revision arthroplasty; Osteolysis; Bone tumor; Knee; Periprosthetic fracture; REPLACEMENT;
D O I
10.1007/s00132-009-1463-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Malignant bone tumors and osteitis of the distal femur are common at every age. These conditions must be considered in patients with total knee arthroplasty and suspicious x-rays. A patient with gross polyethylene-wear-induced osteolysis and periprosthetic fracture is described. Neoplasm and infectious granuloma were excluded through biopsy, and the bone defect was bridged with a rotating hinged distal femoral replacement.
引用
收藏
页码:970 / +
页数:3
相关论文
共 50 条
  • [1] SUPRACONDYLAR FRACTURE OF THE FEMUR ASSOCIATED WITH POLYETHYLENE WEAR AFTER TOTAL KNEE ARTHROPLASTY - A CASE-REPORT
    RAND, JA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (09): : 1389 - 1393
  • [2] Primary total knee arthroplasty for a complex distal femur fracture in the elderly: a case report
    Mounasamy, Varatharaj
    Cui, Quanjun
    Brown, Thomas E.
    Saleh, Khaled J.
    Mihalko, William M.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2007, 17 (05): : 491 - 494
  • [3] Tibial baseplate fracture associated with polyethylene wear and osteolysis after total knee arthroplasty
    Cankaya, Deniz
    Yilmaz, Serdar
    Deveci, Alper
    Ozkurt, Bulent
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2014, 5 (02): : 49 - 51
  • [4] Fracture of the femoral component associated with polyethylene wear and osteolysis after total knee arthroplasty
    Huang, CH
    Yang, CY
    Cheng, CK
    JOURNAL OF ARTHROPLASTY, 1999, 14 (03): : 375 - 379
  • [5] DISTAL FEMUR FRACTURE ABOVE A TOTAL KNEE ARTHROPLASTY
    PATCH, DA
    IORIO, R
    HEALY, WL
    ORTHOPEDICS, 1994, 17 (04) : 371 - 374
  • [6] Polyethylene wear on the distal tibial insert surface in total knee arthroplasty
    Gabriel, SM
    Dennis, DA
    Honey, MJ
    Scott, RD
    KNEE, 1998, 5 (03): : 221 - 228
  • [7] Pathologische Fraktur des distalen Femurs bei Knie-TEPPolyethylenabriebinduzierte Osteolyse? – ein FallberichtPathologic fracture of the distal femur in total knee arthroplastyPolyethylene-wear-induced osteolysis? – a case report
    M. Napp
    M. Frank
    M. Witt
    Der Orthopäde, 2009, 38 : 970 - 973
  • [8] Periprosthetic Distal Femur Fracture after Total Knee Arthroplasty: A Systematic Review
    Ebraheim, Nabil A.
    Kelley, Leanne H.
    Liu, Xiaochen
    Thomas, Ian S.
    Steiner, Robert B.
    Liu, Jiayong
    ORTHOPAEDIC SURGERY, 2015, 7 (04) : 297 - 305
  • [9] Retrograde Intramedullary Nail for Distal Femur Fracture, Through a Total Knee Arthroplasty
    Davis, Max
    Wilson, Jenna
    Weick, Jack
    Hake, Mark
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2021, 35 : S30 - S31
  • [10] Long Term Complications Due to Polyethylene Wear in Total Knee Arthroplasty: a Case Report
    Aurich, Matthias
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2017, 155 (02): : 226 - 228