Evaluation of an indirect immunofluorescence assay for strongyloidiasis as a tool for diagnosis and follow-up

被引:55
|
作者
Boscolo, Marina
Gobbo, Maria
Mantovani, William
Degani, Monica
Anselmi, Mariella
Monteiro, Geraldo Badona
Marocco, Stefania
Angheben, Andrea
Mistretta, Manuela
Santacatterina, Maria
Tais, Stefano
Bisoffi, Zeno
机构
[1] Sacro Cuore Hosp, Ctr Trop Dis, I-37024 Verona, Italy
[2] Univ Verona, Med & Publ Hlth Dept, I-37100 Verona, Italy
关键词
D O I
10.1128/CVI.00278-06
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The diagnostic accuracy of an indirect immunofluorescence antibody test (IFAT) for Strongyloides stercoralis at different serum antibody titers was evaluated. To assess diagnostic sensitivity, sera from 156 patients with known strongyloidiasis were collected. Negative control sera were obtained from a composite group of 427 subjects (blood donors and hospitalized patients). With an area under the receiver-operating characteristic plot of 0.98, the IFAT showed a high level of diagnostic accuracy for strongyloidiasis. An antibody titer of >= 1:20, with 97% sensitivity and 98% specificity, was identified as the diagnostic threshold with the best overall performance. Cross-reactions were evaluated with 41 additional samples from patients with other known helminth infections, and the IFAT detected low-titer positivity in only one subject with filariasis. A positive IFAT result at an antibody dilution of >= 1:80 was virtually 100% specific, with 71% sensitivity. To test the usefulness of the IFAT as a monitoring tool, the changes in specific-antibody titers after treatment in a group of 155 patients were evaluated. Seroreversion or a decrease in antibody titer of twofold or more was observed in 60% of the patients. Response to treatment was directly correlated to the initial antibody titer, and a baseline titer of >= 1:80 was identified as the best predictor of response. In conclusion, a positive IFAT result at an antibody dilution of >= 1:20 is the optimal cutoff for screening. A titer of >= 1:80, with virtually no false-positive result, is a reliable cutoff for a serological assessment of treatment efficacy and for inclusion in clinical trials.
引用
收藏
页码:129 / 133
页数:5
相关论文
共 50 条
  • [1] Immunofluorescence assay for diagnosis of strongyloidiasis in immunocompromised patients
    Gottardi, Maiara
    Paula, Fabiana M.
    Corral, Marcelo A.
    Meisel, Dirce Mary C.
    Costa, Silvia F.
    Abdala, Edson
    Pierrotti, Ligia C.
    Yamashiro, Juliana
    Chieffi, Pedro Paulo
    Gryschek, Ronaldo Cesar B.
    INFECTIOUS DISEASES, 2015, 47 (08) : 550 - 554
  • [2] QUANTITATIVE INDIRECT IMMUNOFLUORESCENCE AS AN ALTERNATIVE TO WESTERN-BLOT FOR THE DIAGNOSIS AND FOLLOW-UP OF PEDIATRIC AIDS
    CALAROTA, S
    LIBERATORE, D
    RABINOVICH, R
    LIBONATTI, O
    PERALTA, LM
    PEDIATRIC AIDS AND HIV INFECTION-FETUS TO ADOLESCENT, 1994, 5 (02): : 97 - 100
  • [3] EVALUATION OF INDIRECT IMMUNOFLUORESCENCE AS A CONFIRMATORY ASSAY IN THE SEROLOGICAL DIAGNOSIS OF HIV INFECTION
    PICCHIO, GR
    MUCHINIK, GR
    MEDICINA-BUENOS AIRES, 1988, 48 (02) : 120 - 124
  • [4] Short report:: Improved diagnosis and follow-up of canine leishmaniasis using amastigote-based indirect immunofluorescence
    Fernández-Pérez, FJ
    Méndez, S
    De la Fuente, C
    Gómez-Muñoz, MT
    Cuquerella, M
    Alunda, JM
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 1999, 61 (04): : 652 - 653
  • [5] Evaluation of the new Hevylite™ IgA assay for the diagnosis and follow-up of monoclonal gammopathies
    Lakomy, Daniela
    Lemaire-Ewing, Stephanie
    Denimal, Damien
    Bastie, Jean-Noel
    Lafon, Ingrid
    Caillot, Denis
    ANNALES DE BIOLOGIE CLINIQUE, 2013, 71 (02) : 157 - 163
  • [6] THE INDIRECT IMMUNOFLUORESCENCE ASSAY IN THE DIAGNOSIS OF HUMAN ROTAVIRUS GASTROENTERITIS
    HARSI, CM
    CANDEIAS, JAN
    REVISTA DE MICROBIOLOGIA, 1991, 22 (04): : 282 - 287
  • [7] The Laboratory Diagnosis and Follow Up of Strongyloidiasis: A Systematic Review
    Requena-Mendez, Ana
    Chiodini, Peter
    Bisoffi, Zeno
    Buonfrate, Dora
    Gotuzzo, Eduardo
    Munoz, Jose
    PLOS NEGLECTED TROPICAL DISEASES, 2013, 7 (01):
  • [8] Follow-up index as indirect measure of reliability of follow-up studies
    Weiss, S.
    von Allmen, R.
    Kuemmerli, C.
    Schmidli, J.
    Tevaearai, H.
    Dick, F.
    BRITISH JOURNAL OF SURGERY, 2014, 101 : 20 - 20
  • [9] Biotinidase deficiency—Diagnosis by enzyme assay and a follow-up study
    N. Ananth
    G. S. Praveen Kumar
    Indian Journal of Clinical Biochemistry, 2003, 18 (2) : 23 - 26
  • [10] Evaluation of indirect immunofluorescence assay in patients with autoimmune diseases
    Sridhar, S.
    Vasanthy, N.
    AFRICAN JOURNAL OF MICROBIOLOGY RESEARCH, 2012, 6 (22): : 4634 - 4638