Ultrafiltration in a tubular membrane inserted concentrically with a solid rod of varying radius for improved performance

被引:2
|
作者
Yeh, H. M. [1 ]
Chen, Y. F. [1 ]
机构
[1] Tamkang Univ, Dept Chem & Mat Engn, Tamsui 251, Taipei County, Taiwan
关键词
Ultrafiltration; Permeate-flux analysis; Solid-rod module; Rod-radius variation; CONCENTRATION POLARIZATION; FLUX; MICROFILTRATION; ENHANCEMENT; SPACERS; MODULES; SYSTEMS;
D O I
10.1016/j.desal.2008.07.021
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Resistance-in-series analysis of the permeate flux for ultrafiltration in a tubular membrane inserted concentrically with a solid rod, having rod radius varied linearly along the tube axis with rod volume kept unchanged, was carried out by mass and momentum balances under various feed solution concentrations and transmembrane pressures. The correlation predictions qualitatively confirm with the experimental results, especially for the device with rod radius increased linearly, and for the operations under lower transmembrane pressure and smaller volumetric flow rate. Both theoretical predictions and experimental results show that considerable improvement in performance is obtained if the rod radius increases along the tube axis of a solid-rod tubular-membrane module.
引用
收藏
页码:476 / 489
页数:14
相关论文
共 44 条
  • [1] Membrane ultrafiltration in a tubular module with a steel rod inserted concentrically for improved performance
    Yeh, HM
    Chen, HY
    Chen, KT
    JOURNAL OF MEMBRANE SCIENCE, 2000, 168 (1-2) : 121 - 133
  • [2] Effect of Ring Density on the Performance in a Tubular Ultrafiltration Membrane Inserted concentrically with a Ring Rod
    Yeh, Ho-Ming
    Shi, Miau-Ying
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2008, 11 (02): : 195 - 200
  • [3] Effect of gradually varying baffled-ring distance on ultrafiltration in tubular membranes inserted concentrically with a ring rod
    Yeh, Ho-Ming
    Li, Cha-Hsing
    Lin, Cha-Chun
    DESALINATION AND WATER TREATMENT, 2011, 26 (1-3) : 236 - 242
  • [4] Effects of ring number and baffled-ring distances on ultrafiltration in the tubular membrane inserted concentrically with a ring rod
    Yeh, Ho-Ming
    Ho, Chii-Dong
    Li, Cha-Hsin
    MEMBRANE AND WATER TREATMENT, 2012, 3 (01): : 51 - 62
  • [5] Effect of rod-radius variation on ultrafiltration in a solid-rod tubular-membrane
    Yeh, HM
    Huang, PC
    JOURNAL OF MEMBRANE SCIENCE, 2004, 243 (1-2) : 357 - 364
  • [6] Modified analysis of permeate flux for ultrafiltration in a solid-rod tubular membrane
    Yeh, HM
    Chen, YF
    JOURNAL OF MEMBRANE SCIENCE, 2005, 251 (1-2) : 255 - 261
  • [7] Effect of varying incidental angles of a wire-rod insert on the performance of tubular ultrafiltration membranes
    Yeh, HM
    Liu, TC
    Huang, PC
    DESALINATION, 2004, 170 (01) : 15 - 25
  • [8] Ferroelectric ultrafiltration membrane with improved antifouling performance
    Pu, Liangtao
    Su, Chang
    Zuo, Yanting
    Chen, Yonglei
    Du, Erdeng
    Xu, Xia
    Peng, Mingguo
    SEPARATION AND PURIFICATION TECHNOLOGY, 2025, 359
  • [9] Prediction of permeate flux for ultrafiltration in wire-rod tubular-membrane modules
    Yeh, HM
    Dong, JF
    Hsieh, MJ
    Yang, CC
    JOURNAL OF MEMBRANE SCIENCE, 2002, 209 (01) : 19 - 26
  • [10] Improvement of ultrafiltration performance in tubular membranes using a twisted wire-rod assembly
    Yeh, HM