Radon. Methods of measurement and Concentration Reduction in Various Spaces

被引:2
|
作者
Cucu, Marina Ionela [1 ]
Dupleac, Daniel [1 ]
机构
[1] Univ Politehn Bucuresti, Bucharest, Romania
关键词
council directive; national action plan; radon;
D O I
10.1109/ciem46456.2019.8937589
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Radon is a radioactive gas of natural origins, coming from the disintegration of uranium from the soil, which concentrates in confined places. It is present in soils, water, building materials and can be transported through porous media, especially by convection and diffusion. The COUNCIL DIRECTIVE 59/2013/EURATOM of 5 December 2013 laying down basic safety standards for protection against the danger arising from exposure to ionizing radiation addresses radon at workplaces and at homes. Radon is directly mentioned in the Basic Safety Standards Directive through Article 54 "Workplace Radon levels", also Article 74 is concerning about "Indoor Radon levels" and the Article 103: "National action plan". The new Directive brings significant changes, with respect to the former Directive 96/29 EURATOM, in terms of protection measures related to exposures due to inhalation of Radon progeny not only in work environments but also in dwellings. Romania, having the status of a EURATOM/EU member, has to implement the directive requirements.
引用
收藏
页码:398 / 402
页数:5
相关论文
共 50 条
  • [1] TURBIDIMETRY FOR MEASUREMENT OF RADON CONCENTRATION
    WANG, HQ
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 495 - 498
  • [2] Study on radon concentration measurement in soil
    Zhao, Gui-Zhi
    Xiao, De-Tao
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2007, 27 (03): : 583 - 587
  • [3] Study, measurement and reduction of the radon concentration in the University School of Technical Architecture of the University of Coruna
    Otero-Pazos, A.
    Fernandez-Ibanez, I.
    Pinon-Pazos, A. J.
    Calvo-Rolle, J. L.
    Giz-Novo, J.
    INFORMES DE LA CONSTRUCCION, 2017, 69 (547)
  • [4] Studies on indoor radon concentration and its reduction
    Watanabe, H
    MOKUZAI GAKKAISHI, 2000, 46 (02): : A13 - A13
  • [5] Various methods for calibration of equipment for activity concentration measurement of noble gases
    Szorenyi, A
    Szucs, L
    Vagvolgyi, J
    APPLIED RADIATION AND ISOTOPES, 1998, 49 (9-11) : 1207 - 1211
  • [6] MEASUREMENT OF RADON CONCENTRATION IN WATER USING THE PORTABLE RADON SURVEY METER
    Yokoyama, S.
    Mori, N.
    Shimo, M.
    Fukushi, M.
    Ohnuma, S.
    RADIATION PROTECTION DOSIMETRY, 2011, 146 (1-3) : 23 - 26
  • [7] Radon concentration measurement with a high-sensitivity radon detector at the Yemilab
    Seo, Kyung Min
    Kim, Hyunsoo
    Kim, Yeong Duk
    Lee, Hye Young
    Lee, Jaison
    Lee, Moo Hyun
    So, Jungho
    Yoon, Sang Cheol
    Yoon, Young Soo
    JOURNAL OF INSTRUMENTATION, 2024, 19 (05):
  • [8] RADON MEASUREMENT METHODS .A. REVIEW
    STRYDOM, R
    LEUSCHNER, AH
    HEALTH PHYSICS, 1987, 52 (01): : 112 - 112
  • [9] Measurement of radon concentration levels in Pakistan: An overview
    Matiullah
    Muhammad, Wazir
    INDOOR AND BUILT ENVIRONMENT, 2017, 26 (10) : 1319 - 1334
  • [10] A SCINTILLATION COUNTER FOR MEASUREMENT OF RADON CONCENTRATION IN AIR
    COLLINSON, AJL
    HAQUE, AKM
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1963, 40 (11): : 521 - &