Phantom-based characterization of distortion on a magnetic resonance imaging simulator for radiation oncology

被引:43
|
作者
Huang, Ke [1 ,2 ]
Cao, Yue [1 ]
Baharom, Umar [3 ]
Balter, James M. [1 ]
机构
[1] Univ Michigan Hosp, Dept Radiat Oncol, Ann Arbor, MI 48105 USA
[2] Georgia Regents Univ, Dept Radiat Oncol, Augusta, GA 30912 USA
[3] Integrated Med Technol, Troy, NY 12180 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 02期
关键词
MR image; distortion; sub-voxel accuracy; template matching; normalized cross correlation; GEOMETRIC DISTORTION; STRUCTURAL MRI; IMAGES; LOCALIZATION; REGISTRATION; ACCURACY;
D O I
10.1088/0031-9155/61/2/774
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
One of the major issues potentially limiting treatment planning with solely MR images is the possibility of geometric distortion inherent in MR images. We designed a large distortion phantom containing a 3D array of spheres and proposed a three-dimensional (3D) approach to determine the distortion of MR image volume. The approach to overcome partially filled spheres is also presented. The phantom was assembled with a 3D array of spheres filled with contrast and was scanned with a 3T MRI simulator. A 3D whole-sphere or half-sphere template is used to match the image pattern. The half-sphere template is used when the normalized cross-correlation value for the whole-sphere template is below a predetermined threshold. Procrustes method was applied to remove the shift induced by rotation and translation of the phantom. Then the distortion map was generated. Accuracy of the method was verified using CT images of a small phantom of the same design. The analysis of the small phantom showed that the method is accurate with an average offset of estimated sphere center 0.12 +/- 0.04 mm. The Procrustes analysis estimated the rotation angle to be 1.95 degrees and 0.01 degrees, respectively, when the phantom was placed at 2 degrees and 0 degrees from the ceiling laser. The analysis showed that on the central plane through the magnet center, the average displacement is less than 1 mm for all radii. At distal planes, when the radius is less than 18 cm, the average displacement is less than 1 mm. However, the average displacement is over 1 mm but still less than 1.5 mm for larger radii. A large distortion phantom was assembled and analysis software was developed to characterize distortions in MRI scans. The use of two templates helps reduce the potential impact of residual air bubbles in some of the spheres.
引用
收藏
页码:774 / 790
页数:17
相关论文
共 50 条
  • [1] Customization of neonatal functional magnetic resonance imaging: A preclinical phantom-based study
    Quinones, Juan F.
    Schmitt, Tina
    Pavan, Tommaso
    Hildebrandt, Andrea
    Heep, Axel
    PLOS ONE, 2024, 19 (11):
  • [2] Phantom-based evaluation of geometric distortions in functional magnetic resonance and diffusion tensor imaging
    Mattila, Seppo
    Renvall, Ville
    Hiltunen, Jaana
    Kirven, Douglas
    Sepponen, Raimo
    Hari, Riitta
    Tarkiainen, Antti
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (04) : 754 - 763
  • [3] Reproducibility of geometric distortion in magnetic resonance imaging based on phantom studies
    Mizowaki, T
    Nagata, Y
    Okajima, K
    Kokubo, M
    Negoro, Y
    Araki, N
    Hiraoka, M
    RADIOTHERAPY AND ONCOLOGY, 2000, 57 (02) : 237 - 242
  • [4] Design and construction of a customizable phantom for the characterization of the three-dimensional magnetic resonance imaging geometric distortion
    Torfeh, Tarraf
    Hammoud, Rabih
    Paloor, Satheesh
    Arunachalam, Yoganathan
    Aouadi, Souha
    Al-Hammadi, Noora
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (12): : 149 - 157
  • [5] Phantom-based performance evaluation: Application to brain segmentation from magnetic resonance images
    Moretti, B
    Fadili, JM
    Ruan, S
    Bloyet, D
    Mazoyer, B
    MEDICAL IMAGE ANALYSIS, 2000, 4 (04) : 303 - 316
  • [6] Simultaneous PET/MRI with 13C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification
    Adam E. Hansen
    Flemming L. Andersen
    Sarah T. Henriksen
    Alexandre Vignaud
    Jan H. Ardenkjaer-Larsen
    Liselotte Højgaard
    Andreas Kjaer
    Thomas L. Klausen
    EJNMMI Physics, 3
  • [7] Phantom-based assessment of motion and needle targeting accuracy of robotic devices for magnetic resonance imaging-guided needle biopsy
    Antoniou, Anastasia
    Nikolaou, Anastasia
    Evripidou, Nikolas
    Georgiou, Andreas
    Filippou, Antria
    Zinonos, Vasiliki
    Giannakou, Marinos
    Chrysanthou, Antreas
    Ioannides, Cleanthis
    Damianou, Christakis
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2023, 19 (05):
  • [8] Simultaneous PET/MRI with 13C magnetic resonance spectroscopic imaging (hyperPET): phantom-based evaluation of PET quantification
    Hansen, Adam E.
    Andersen, Flemming L.
    Henriksen, Sarah T.
    Vignaud, Alexandre
    Ardenkjaer-Larsen, Jan H.
    Hojgaard, Liselotte
    Kjaer, Andreas
    Klausen, Thomas L.
    EJNMMI PHYSICS, 2016, 3 (01):
  • [9] Interventional Radiation Oncology (IRO): Transition of a magnetic resonance simulator to a brachytherapy suite
    Anderson, Roberta
    Armour, Elwood
    Beeckler, Courtney
    Briner, Valerie
    Choflet, Amanda
    Cox, Andrea
    Fader, Amanda N.
    Hannah, Marie N.
    Hobbs, Robert
    Huang, Ellen
    Kiely, Marilyn
    Lee, Junghoon
    Morcos, Marc
    McMillan, Paige E.
    Miller, Dave
    Ng, Sook Kien
    Prasad, Rashmi
    Souranis, Annette
    Thomsen, Robert
    DeWeese, Theodore L.
    Viswanathan, Akila N.
    BRACHYTHERAPY, 2018, 17 (03) : 587 - 596
  • [10] Introduction: Magnetic Resonance Imaging Comes of Age in Radiation Oncology
    Menard, Cynthia
    van der Heide, Uulke A.
    SEMINARS IN RADIATION ONCOLOGY, 2014, 24 (03) : 149 - 150