Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures

被引:5
|
作者
Jeong, Jae-Jung [1 ]
Park, Sang-Eun [1 ]
Lee, Hwan-Hee [1 ]
Ji, Jong-Hun [1 ]
Park, Min-Sik [1 ]
Park, Yong-Taek [1 ]
机构
[1] Catholic Univ Korea, Coll Med, Daejeon St Marys Hosp, Dept Orthopaed Surg, 520-2 Deahung Dong, Daejeon 302803, South Korea
关键词
Minimally invasive plate osteosynthesis (MIPO); Spiral humeral shaft fractures; Narrow locking compression plate; Long philos plate; DISTAL FEMORAL FRACTURES; FIXATION; STABILIZATION; MANAGEMENT; STANDARD; LISS; NAIL;
D O I
10.1186/s12891-019-2757-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Our hypothesis was that minimally invasive plate osteosynthesis (MIPO) using long philos plate (LPP) would show better clinical and radiological outcomes and less complications than narrow locking compression plate (NLCP) for spiral humerus shaft fractures with or without metaphyseal fracture extension. Methods From January 2009 to May 2016, we retrospectively studied 35 patients who underwent MIPO for spiral humerus shaft fractures with or without metaphyseal fracture extension (AO classification 12 A, B, C except A3). Eighteen patients underwent MIPO with a 4.5 mm NLCP (group I) in the early period of this study, while 17 patients underwent MIPO with LPP (group II) in the later period. Range of motion (ROM), pre- and post-operative anteroposterior (AP) and lateral angulation of the fracture, operation time, amount of bleeding, and functional outcomes including American Shoulder and Elbow Surgeons score, University of California at Los Angeles score, and Simple Shoulder Test score were analyzed at the final follow up. Results All patients had complete bony union and achieved satisfactory functional outcomes except 2 patients. In LPP group, better outcomes in postoperative fracture angulation on X-ray and operation time (p < 0.05) were shown. But, two revision surgery with NLCP and bone graft was performed owing to 2 metal failures. Conclusions In spiral humeral shaft fractures, LPP group showed better fracture reduction on X-ray and shorter operation time except metal failure owing to weak fixation. Even though MIPO technique using LPP is easier and more accurate reduction method, rigid fixation should be considered.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures
    Jae-Jung Jeong
    Sang-Eun Park
    Hwan-Hee Lee
    Jong-Hun Ji
    Min-Sik Park
    Yong-Taek Park
    BMC Musculoskeletal Disorders, 20
  • [2] Minimally invasive plate osteosynthesis with PHILOS plate for proximal humerus fractures
    Gonc, Ugur
    Atabek, Mesut
    Teker, Kursat
    Tanriover, Altug
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2017, 51 (01) : 17 - 22
  • [3] Minimally invasive percutaneous plate osteosynthesis for the treatment of proximal humerus fractures in osteoporotic patients with Philos plate
    Sahu, R. J. L.
    BANGLADESH JOURNAL OF MEDICAL SCIENCE, 2013, 12 (02): : 140 - 145
  • [4] Minimally invasive plate osteosynthesis using a locking compression plate for diaphyseal humeral fractures
    Malhan, Sachit
    Thomas, Simon
    Srivastav, Shekhar
    Agarwal, Shekhar
    Mittal, Vivek
    Nadkarni, Biren
    Gulati, Divesh
    JOURNAL OF ORTHOPAEDIC SURGERY, 2012, 20 (03) : 292 - 296
  • [5] Minimal invasive PHILOS®-plate osteosynthesis of proximal humerus fractures
    Acklin, Y. P.
    Jenni, R.
    Walliser, M.
    Sommer, C.
    BRITISH JOURNAL OF SURGERY, 2007, 94 (06) : 769 - 769
  • [6] Minimal invasive long PHILOS®-plate osteosynthesis in metadiaphyseal fractures of the proximal humerus
    Rancan, Mario
    Dietrich, Michael
    Lamdark, Tenzin
    Can, Uenal
    Platz, Andreas
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (12): : 1277 - 1283
  • [7] Minimal invasive long PHILOS® -plate osteosynthesis in metadiaphyseal fractures of the proximal humerus
    Rancan, M.
    Dietrich, M.
    Lamdark, T.
    Can, Ue.
    Platz, A.
    BRITISH JOURNAL OF SURGERY, 2010, 97 : 18 - 19
  • [8] Minimally invasive plate osteosynthesis with locking plate for metastatic humeral fractures
    Matsumura, Tomohiro
    Saito, Tomohiro
    Akiyama, Toru
    Takeshita, Katsushi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2022, 27 (06) : 1309 - 1314
  • [9] Minimally invasive plate osteosynthesis with a locking compression plate is superior to open reduction and internal fixation in the management of the proximal humerus fractures
    Tao Lin
    Baojun Xiao
    Xiucai Ma
    Dehao Fu
    Shuhua Yang
    BMC Musculoskeletal Disorders, 15
  • [10] Minimally invasive plate osteosynthesis with a locking compression plate is superior to open reduction and internal fixation in the management of the proximal humerus fractures
    Lin, Tao
    Xiao, Baojun
    Ma, Xiucai
    Fu, Dehao
    Yang, Shuhua
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15