The composite structure of peak 5 in the glow curve of LiF:Mg,Ti (TLD-100):: Confirmation of peak 5a arising from a locally trapped electron-hole configuration

被引:0
|
作者
Horowitz, YS [1 ]
Oster, L [1 ]
Satinger, D [1 ]
Biderman, S [1 ]
Einav, Y [1 ]
机构
[1] Ben Gurion Univ Negev, Dept Phys, IL-84105 Beer Sheva, Israel
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The hypothesis that glow peak 5a arises from localised e-h capture is confirmed by the following experimental observations: (i) The high conversion efficiency (CE) (CE5a-->4 = 3 +/- 0.5) of peak 5a to peak 4 (a hole-only trap) deduced from detailed 1(m)-T-stop optical bleaching studies at 310 nm compared to the much lower CE of peak 5 (an electron-only trap) (CE5-->4 = 0.0026 +/- 0.012). (ii) The lack of an increase in the sensitivity of glow peak 5a following 2.6 MeV and 6.8 MeV He ion irradiation in 'sensitised' material compared to the factor two increase in the sensitivity of peak 5; (S/S-o)(5a) = 0.86 +/- 0.12, compared to (S/S-o)(5) = 2.0 +/- 0.2. (iii) The late entry into saturation of the 2.6 MeV and 6.8 MeV He ion TL-fluence response curves for peak 5a compared to peak 5 in sensitised and normal material resulting in the following values for the track radial saturation parameter; (r(50))(5a) = 100 +/- 20 Angstroms compared to (r(50))(5) = 380 +/- 30 Angstroms. (iv) The low value of 0.1 for the 'track-escape' parameter of peak 5a deduced from the Extended Track Interaction Model analysis of He ion TL fluence response compared to order of magnitude greater values for peaks 5 and 5b.
引用
收藏
页码:123 / 126
页数:4
相关论文
共 33 条
  • [1] The composite structure of peak 5 in the glow curve of LiF:Mg,Ti (TLD-100):: Confirmation of peak 5a arising from a locally trapped electron-hole configuration
    Horowitz, YS
    Oster, L
    Satinger, D
    Biderman, S
    Einav, Y
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 123 - 126
  • [2] Investigation of the composite structure of peak 5 in the thermoluminescent glow curve of LiF:Mg,Ti (TLD-100) using optical bleaching
    Weizman, Y
    Horowitz, YS
    Oster, L
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (16) : 2118 - 2127
  • [3] Advanced multistage deconvolution applied to composite glow peak 5 in LiF:Mg,Ti (TLD-100)
    Horowitz, Y. S.
    Fuks, E.
    Oster, L.
    Podpalov, L.
    Belaish, Y.
    Ben Shachar, B.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 322 - 325
  • [4] Defect structure of glow peak 1 in LiF:Mg,Ti (TLD-100)
    Yazici, A. Necmeddin
    Turkish Journal of Physics, 2002, 26 (06): : 473 - 481
  • [5] The concept of quasi-tissue-equivalent nanodosimeter based on the Glow Peak 5a/5 in LiF:Mg, Ti (TLD-100)
    L. Oster
    Y. S. Horowitz
    S. Biderman
    J. Haddad
    Australasian Physics & Engineering Sciences in Medicine, 2003, 26 (4): : 173 - 178
  • [6] The effects of ionisation density on the glow curve structure of LiF:Mg,Ti (TLD-100):: The behaviour of composite glow peak 5 in 'slow-cooled' material
    Fuks, E.
    Horowitz, Y.
    Oster, L.
    Belaish, Y.
    Ben Shahar, B.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 194 - 197
  • [7] COMPUTERIZED GLOW CURVE DECONVOLUTION APPLIED TO THE ANALYSIS OF THE KINETICS OF PEAK 5 IN LIF-MG,TI (TLD-100)
    YOSSIAN, D
    HOROWITZ, YS
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1995, 28 (07) : 1495 - 1508
  • [8] Glow curve analysis of composite peak 5 in LiF:Mg,Ti (TLD-100) using optical bleaching, thermal annealing and computerised glow curve deconvolution
    Biderman, S
    Horowitz, YS
    Oster, L
    Einav, Y
    Dubi, Y
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A69 - A72
  • [9] Glow curve analysis of composite peak 5 in LiF:Mg,ti (TLD-100) using optical bleaching, thermal annealing and computerised glow curve deconvolution
    Biderman, S
    Horowitz, YS
    Oster, L
    Einav, Y
    Dubi, Y
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 69 - 72
  • [10] Nanodosimetric kinetic model incorporating localized and delocalized recombination: Application to the prediction of the electron dose response of the peak 5a/5 ratio in the glow curve of LiF:Mg,Ti (TLD-100)
    Eliyahu, I.
    Horowitz, Y. S.
    Oster, L.
    Druzhyna, S.
    Mardor, I.
    RADIATION MEASUREMENTS, 2014, 71 : 226 - 231