Direct comparison of solid-phase extraction and solid-phase microextraction for the gas chromatographic determination of dibenzylamine in artificial saliva leachates from baby bottle teats

被引:5
|
作者
Niessner, G [1 ]
Klampfl, CW [1 ]
机构
[1] Johannes Kepler Univ Linz, Dept Analyt Chem, A-4040 Linz, Austria
关键词
gas chromatography; mass spectrometric detection; solid-phase extraction (SPE); solid-phase microextraction (SPME); dibenzylamine; saliva;
D O I
10.1016/S0003-2670(00)00833-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two sample preparation methods for the determination of dibenzylamine (DBA) in artificial saliva leachates from rubber baby bottle nipples have been developed, using either solid-phase extraction (SPE) with N-vinylpyrrolidone/divinylbenzene as the sorbent or solid-phase microextraction (SPME) with a polyacrylate coated fiber. The baby bottle nipples were immersed into artificial saliva for 6 h, a part of the solution was brought to pH 9 for SPE or pH 10 for SPME and the analyte was extracted by SPE or SPME. After elution with ethyl acetate (SPE) or thermal desorption (SPME) DBA was determined by gas chromatography with mass spectrometric detection. The main advantages of SPE were superior ruggedness and stability as well as the possibility of preparing several samples simultaneously. SPME offered a greater sensitivity and much smaller sample volumes were required. The results obtained for the investigated rubber baby bottle nipples were almost identical with both the methods showing deviations of less than 3%. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 50 条
  • [1] Sample preparation for gas chromatography with solid-phase extraction and solid-phase microextraction
    Penton, ZE
    ADVANCES IN CHROMATOGRAPHY, VOL 37, 1997, 37 : 205 - 236
  • [2] Sample Preparation for Gas Chromatography with Solid-Phase Extraction and Solid-Phase Microextraction
    Penton, Z. E.
    Advances in Chromatography, (37):
  • [3] Comparison of Solid-Phase Extraction and Solid-Phase Microextraction Using Octadecylsilane Phase for the Determination of Pesticides in Water Samples
    Prieto, Avismelsi
    Araujo, Lilia
    Navalon, Alberto
    Vilchez, Jose L.
    CURRENT ANALYTICAL CHEMISTRY, 2009, 5 (03) : 219 - 224
  • [4] Determination of nitrate esters in water samples comparison of efficiency of solid-phase extraction and solid-phase microextraction
    Jezova, Vera
    Skladal, Jan
    Eisner, Ales
    Bajerova, Petra
    Ventura, Karel
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1174 (1-2) : 13 - 19
  • [5] Behaviour of carbamate pesticides in gas chromatography and their determination with solid-phase extraction and solid-phase microextraction as preconcentration steps
    Carabias-Martínez, R
    García-Hermida, U
    Rodríguez-Gonzalo, E
    Ruano-Miguel, L
    JOURNAL OF SEPARATION SCIENCE, 2005, 28 (16) : 2130 - 2138
  • [6] DETERMINATION OF PHENOLS BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHIC ANALYSIS
    BUCHHOLZ, KD
    PAWLISZYN, J
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (13) : 2844 - 2848
  • [7] Optimizing solid-phase microextraction - Gas chromatographic injections
    Okeyo, P
    Snow, NH
    LC GC NORTH AMERICA, 1997, 15 (12) : 1130 - +
  • [8] Determination of terpenoids in Baijiu using solid-phase extraction combined with headspace solid-phase microextraction
    Feng, Minxue
    Li, Chenyao
    Wang, Chao
    Zhu, Guojun
    Lu, Jun
    Chen, Yefu
    Xiao, Dongguang
    Guo, Xuewu
    INTERNATIONAL JOURNAL OF FOOD PROPERTIES, 2022, 25 (01) : 2445 - 2456
  • [9] Solid-phase extraction (SPE) and solid-phase microextraction of pyrethroids in water.
    Barrionuevo, WR
    Lanças, FM
    QUIMICA NOVA, 2001, 24 (02): : 172 - 175
  • [10] Gas chromatographic determination of formaldehyde in air using solid-phase microextraction sampling
    Ŝ. Velikonja Bolta
    L. Zupanĉiĉ-Kralj
    J. Marsel
    Chromatographia, 1998, 48 : 95 - 100