What is the validity of self-reported fractures?

被引:17
|
作者
Baleanu, F. [1 ]
Moreau, M. [4 ]
Kinnard, V [3 ]
Iconaru, L. [1 ]
Karmali, R. [1 ]
Paesmans, M. [4 ]
Bergmann, P. [2 ]
Body, J. J. [1 ]
机构
[1] Univ Libre Bruxelles, CHU Brugmann, Dept Endocrinol, Brussels, Belgium
[2] Univ Libre Bruxelles, CHU Brugmann, Dept Nucl Med, Brussels, Belgium
[3] Univ Libre Bruxelles, CHU Brugmann, Dept Internal Med, Brussels, Belgium
[4] Univ Libre Bruxelles, Data Ctr, Inst J Bordet, Brussels, Belgium
来源
BONE REPORTS | 2020年 / 12卷
关键词
Osteoporosis; Fractures; Self-report; Epidemiology; False positives; CLINICAL RISK-FACTORS; OSTEOPOROTIC FRACTURES; POSTMENOPAUSAL WOMEN; COHORT; ACCURACY; MEN; HIP;
D O I
10.1016/j.bonr.2020.100256
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We assessed the validity of self-reported fractures, over a median follow-up period of 6.2 years, in a well characterized population-based cohort of 3560 postmenopausal women, aged 60-85 years, from the Fracture Risk Brussels Epidemiological Enquiry (FRISBEE) study. Incident low-traumatic (falls from a standing height or less) or non-traumatic fractures, including peripheral fractures, were registered during each annual follow-up telephone interview. A self-reported fracture was considered as a true positive if it was validated by written reliable medical reports (radiographs, CT scans or surgical report). False positives fractures were considered to be those for which the radiology report indicated that there was no fracture at the reported site. Among self-reported fractures, false positive rates were 14.4% for all fractures. The rate of false positives of 11.2% (n = 48/429) was not negligible for the four classical major osteoporotic fractures (MOFs: hip, clinical spine, forearm or shoulder fractures). In terms of fracture site, we found the lowest false positive rate (4.4%) at the hip, and the highest (16.8%) at the spine, with the proximal humerus and the wrist in between, at about 10% each. The global rates of false positives were 12.5% (n = 22/176) for other major fractures and 22.3% (n = 49/220) for minor fractures. Younger subjects, individuals with fractures at sites other than the hip, with a lower education level, or with a higher BMI were more likely to report false positive fractures. Our data indicate that the inaccuracy of self-reported fractures is clinically relevant for several major fractures, which could influence any fracture risk prediction model.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Validity of self-reported morbidity
    Prinja, Shankar
    Jeet, Gursimer
    Kumar, Rajesh
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2012, 136 (05) : 722 - 724
  • [2] VALIDITY OF SELF-REPORTED FEAR
    LANYON, RI
    MANOSEVITZ, M
    BEHAVIOUR RESEARCH AND THERAPY, 1966, 4 (04) : 259 - +
  • [3] Validity and Reliability of Self-Reported Diabetes
    Schneider, Andrea L.
    Pankow, James S.
    Heiss, Gerardo
    Selvin, Elizabeth
    DIABETES, 2012, 61 : A382 - A383
  • [4] Validity of self-reported causes of subfertility
    de Boer, EJ
    den Tonkelaar, I
    Burger, CW
    van Leeuwen, FE
    AMERICAN JOURNAL OF EPIDEMIOLOGY, 2005, 161 (10) : 978 - 986
  • [5] Validity of self-reported cardiovascular disease
    Joshi, R.
    Turnbull, F.
    INTERNAL MEDICINE JOURNAL, 2009, 39 (01) : 5 - 6
  • [6] VALIDITY OF SELF-REPORTED PREGRAVID WEIGHT
    YU, SM
    NAGEY, DA
    AMERICAN JOURNAL OF EPIDEMIOLOGY, 1990, 132 (04) : 772 - 772
  • [7] Validity of self-reported nickel allergy
    Josefson, Anna
    Farm, Gunilla
    Meding, Birgitta
    CONTACT DERMATITIS, 2010, 62 (05) : 289 - 293
  • [8] The validity of self-reported dental agenesis
    Baelum, V.
    Nielsen, L. D.
    Greve, L. D.
    Rolling, S.
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2011, 119 (04) : 282 - 287
  • [9] VALIDITY OF SELF-REPORTED RUNNING DISTANCE
    Dideriksen, Mette
    Soegaard, Cristina
    Nielsen, Rasmus O.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2016, 30 (06) : 1592 - 1596
  • [10] The validity of self-reported weights and heights
    Lin, DC
    FASEB JOURNAL, 2006, 20 (05): : A1007 - A1007