Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations

被引:154
|
作者
Jarry, Genevieve [1 ]
Graham, Sean A.
Moseley, Douglas J.
Jaffray, David J.
Siewerdsen, Jeffrey H.
Verhaegen, Frank
机构
[1] McGill Univ, Montreal, PQ H3G 1A4, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 2M9, Canada
[3] Princess Margaret Hosp, Univ Hlth Network, Ontario Canc Inst, Toronto, ON M5G 2M9, Canada
[4] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
关键词
cone-beam CT; scatter; Monte Carlo; scatter correction;
D O I
10.1118/1.2358324
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Kilovoltage (kV) cone beam computed tomography (CBCT) images suffer from a substantial scatter contribution. In this study, Monte Carlo (MC) simulations are used to evaluate the scattered radiation present in projection images. These predicted scatter distributions are also used as a scatter correction technique. Images were acquired using a kV CBCT bench top system. The EGSnrc MC code was used to model the flat panel imager, the phantoms, and the x-ray source. The x-ray source model was validated using first and second half-value layers (HVL) and profile measurements. The HVLs and the profile were found to agree within 3% and 6%, respectively. MC simulated and measured projection images for a cylindrical water phantom and for an anthropomorphic head phantom agreed within 8% and 10%. A modified version of the DOSXYZnrc MC code was used to score phase space files with identified scattered and primary particles behind the phantoms. The cone angle, the source-to-detector distance, the phantom geometry, and the energy were varied to determine their effect on the scattered radiation distribution. A scatter correction technique was developed in which the MC predicted scatter distribution is subtracted from the projections prior to reconstruction. Preliminary testing of the procedure was done with an anthropomorphic head phantom and a contrast phantom. Contrast and profile measurements were obtained for the scatter corrected and noncorrected images. An improvement of 3% for contrast between solid water and a liver insert and 11% between solid water and a Teflon insert were obtained and a significant reduction in cupping and streaking artifacts was observed. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4320 / 4329
页数:10
相关论文
共 50 条
  • [1] Monte Carlo DNA Damage Simulations of kV CBCT Radiation
    Kirby, C.
    Ghasroddashti, E.
    Poirier, Y.
    Tambasco, M.
    Stewart, R. D.
    MEDICAL PHYSICS, 2012, 39 (07) : 4645 - 4646
  • [2] RBE of kV CBCT radiation determined by Monte Carlo DNA damage simulations
    Kirkby, C.
    Ghasroddashti, E.
    Poirier, Y.
    Tambasco, M.
    Stewart, R. D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (16): : 5693 - 5704
  • [3] Monte Carlo Simulations of Relative DNA Damage From KV CBCT Radiation
    Kirkby, C.
    Ghasroddashti, E.
    Poirier, Y.
    Tambasco, M.
    Stewart, R.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [4] A SETUP FOR KV CBCT SCATTER PREDICTION USING MONTE CARLO SIMULATIONS
    Poels, K.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S47 - S48
  • [5] A Setup for Patient Individual KV CBCT Scatter Prediction Using Monte Carlo Simulations
    Poels, K.
    Van den Heuvel, F.
    MEDICAL PHYSICS, 2010, 37 (06) : 3395 - +
  • [6] Comparison of CBCT radiation doses with conventional radiographs in TMJ imaging using Monte Carlo simulations
    Deniz, Yesim
    Eren, Hakan
    Sessiz, Rueya
    Cosan Ata, Gamze
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (01) : 39 - 45
  • [7] Comparison of CBCT radiation doses with conventional radiographs in TMJ imaging using Monte Carlo simulations
    Yeşim Deniz
    Hakan Eren
    Rüya Sessiz
    Gamze Coşan Ata
    Radiation and Environmental Biophysics, 2024, 63 : 39 - 45
  • [8] Validation of MTF measurement for CBCT system using Monte Carlo simulations
    Hao, Ting
    Gao, Feng
    Zhao, Huijuan
    Zhou, Zhongxing
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES IX, 2016, 9700
  • [9] Scattered radiation in portal images: A Monte Carlo simulation and a simple physical model
    Swindell, W
    Evans, PM
    MEDICAL PHYSICS, 1996, 23 (01) : 63 - 73
  • [10] Monte Carlo Characterization of Scattered Radiation Profile in Volumetric 64 Slice CT Using GATE
    Darmian, A. Najafi
    Ay, M. R.
    Pouladian, M.
    Shirazi, A.
    Ghadiri, H.
    Akbarzadeh, A.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 694 - +