Transient heating in fixed length optical cavities for use as temperature and pressure standards

被引:6
|
作者
Ricker, J. [1 ]
Douglass, K. O. [1 ]
Syssoev, S. [2 ]
Stone, J. [3 ]
Avdiaj, S. [1 ,4 ]
Hendricks, J. H. [1 ]
机构
[1] NIST, Thermodynam Metrol Grp, Gaithersburg, MD 20899 USA
[2] MKS Instruments Inc, Andover, MA USA
[3] NIST, Dimens Metrol Grp, Gaithersburg, MD 20899 USA
[4] Univ Prishtina, Dept Phys, Prishtina, Kosovo
关键词
pressure; temperature; standard; FLOC; refractive index; thermal; quantum-based standards;
D O I
10.1088/1681-7575/abe8e0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Optical refractometry techniques enable realization of both pressure and temperature directly from properties of the gas. The NIST refractometer, a fixed length optical cavity (FLOC) has previously been evaluated for operation as pressure standard, and now in this paper, is evaluated for the feasibility of operation as a primary temperature standard as well. The challenge is that during operation, one cavity is filled with gas. Gas dynamics predicts that this will result in heating which in turn will affect the cavity temperature uniformity, impeding the ability to measure the gas temperature with sufficient accuracy to make the standard useful as a primary standard for temperature or pressure. Temperature uniformity across the refractometer must be less than 0.5 mK for measurements of the refractivity to be sufficiently accurate for the FLOC. This paper compares computer modeling to laboratory measurements, enabling us to validate the model to predict thermal behavior and to accurately determine the measurement uncertainty of the technique. The results presented in this paper show that temperature of the glass elements of the refractometer and 'thermal-shell' copper chamber are equivalent to within 0.5 mK after an equilibration time of 3000 s (when going from 1 kPa to 100 kPa). This finding enables measurements of the copper chamber to determine the gas temperature to within an uncertainty (k = 1) of 0.5 mK. Additionally, the NIST refractometer is evaluated for feasibility of operation as temperature standard.
引用
收藏
页数:10
相关论文
共 18 条
  • [1] USE OF LIQUEFIED GASES IN OPTICAL LOW-TEMPERATURE CHAMBER WITH FIXED PRESSURE
    EREMETS, MI
    SHIROKOV, AM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (02) : 562 - 564
  • [2] Optical fibers with interferometric path length stability by controlled heating for transmission of optical signals and as components in frequency standards
    H. Müller
    A. Peters
    C. Braxmaier
    Applied Physics B, 2006, 84 : 401 - 408
  • [3] Optical fibers with interferometric path length stability by controlled heating for transmission of optical signals and as components in frequency standards
    Muller, H.
    Peters, A.
    Braxmaier, C.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 84 (03): : 401 - 408
  • [4] OPTICAL LOW-TEMPERATURE CHAMBER WITH FIXED HYDROSTATIC PRESSURE
    SHIROKOV, AM
    KOSICHKIN, YV
    ANZIN, VB
    ITSKEVICH, ES
    SUKHOPAROV, VA
    CRYOGENICS, 1973, 13 (12) : 728 - 729
  • [5] OPTICAL LOW-TEMPERATURE CHAMBER WITH FIXED HYDROSTATIC PRESSURE
    SHIROKOV, AM
    KOSICHKI.YV
    ANZIN, VB
    ITSKEVIC.ES
    SUKHOPAR.VA
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (03): : 208 - 209
  • [6] Temperature Distribution and Pressure Transient Analysis in Heavy Oil Reservoirs Undergoing Microwave Heating
    Nasser, Ali R.
    Awotunde, Abeeb A.
    Jamal, Mohammad S.
    Tatar, Nasser-Eddine
    Liao, Qinzhuo
    Azad, Madhar
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024, : 4703 - 4720
  • [7] Temperature measurement and optical path-length bias improvement modifications to National Institute of Standards and Technology ozone reference standards
    Norris, James E.
    Choquette, Steven J.
    Viallon, Joele
    Moussay, Philippe
    Wielgosz, Robert
    Guenther, Franklin R.
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2013, 63 (05) : 565 - 574
  • [8] Hybrid Miniature Fabry-Perot Sensor with Dual Optical Cavities for Simultaneous Pressure and Temperature Measurements
    Bae, Hyungdae
    Yun, David
    Liu, Haijun
    Olson, Douglas A.
    Yu, Miao
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2014, 32 (08) : 1585 - 1593
  • [9] Miniature Fabry-Perot sensor with polymer dual optical cavities for simultaneous pressure and temperature measurements
    Bae, Hyungdae
    Yu, Miao
    SENSING TECHNOLOGIES FOR GLOBAL HEALTH, MILITARY MEDICINE, AND ENVIRONMENTAL MONITORING IV, 2014, 9112
  • [10] Transient temperature during pulsed excimer laser heating of thin polysilicon films obtained by optical reflectivity measurement
    Xu, X.
    Grigoropoulos, C.P.
    Russo, R.E.
    Journal of Heat Transfer, 1995, 117 (01): : 17 - 24