Characterization of metal complexes with metallothioneins by capillary zone electrophoresis (CZE) with ICP-MS and electrospray (ES)-MS detection

被引:66
|
作者
Mounicou, S
Polec, K
Chassaigne, H
Potin-Gautier, M
Lobinski, R
机构
[1] Univ Pau & Pays Adour, CNRS UMR 5034, F-64053 Pau, France
[2] Warsaw Univ Technol, Fac Chem, Dept Analyt Chem, PL-00664 Warsaw, Poland
关键词
D O I
10.1039/b000546k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The complementarity of CZE-ICP-MS and CZE-ES-MS couplings was evaluated for the characterization of metal complexes with metallothionein (MT) isoforms. The preparations characterized included the rabbit liver MT and its further purified MT-1 and MT-2 isoforms. The CZE-ICP-MS electrophoregrams showed the presence of several well (often baseline) separated Gaussian-shape peaks. ES-MS was used for the identification of these signals; mass spectra taken at the peak apexes were complex and indicated the co-existence of several metal complexes (possibly with different isoforms) within each peak. Many of these complexes could be identified on the basis of the molecular mass. The study highlights the attractive potential of CZE-ICP-MS and CZE-ES-MS when used in parallel for the characterization of metal complexes with biomolecular ligands. The inherent discrepancy between the sensitivities of ICP-MS and ES-MS is partly alleviated by the fact that the metal (detected by ICP-MS) constitutes only a small fraction of the total molecule (detected by ES-MS), and by the smaller dilution factor with the makeup sheath flow in ES-MS than in ICP-MS.
引用
收藏
页码:635 / 642
页数:8
相关论文
共 50 条
  • [1] Determination of phytochelatins by capillary zone electrophoresis with electrospray tandem mass spectrometry detection (CZE-ES MS/MS)
    Mounicou, S
    Vacchina, V
    Szpunar, J
    Potin-Gautier, M
    Lobinski, R
    ANALYST, 2001, 126 (05) : 624 - 632
  • [2] Characterization of metal glycinate complexes by electrospray Q-TOF-MS/MS and their determination by capillary electrophoresis–ICP-MS: application to premix samples
    Véronique Vacchina
    Sébastien Oguey
    Catherine Ionescu
    David Bravo
    Ryszard Lobinski
    Analytical and Bioanalytical Chemistry, 2010, 398 : 435 - 449
  • [3] ICP-MS for specific detection in capillary electrophoresis
    Alvarez-Llamas, G
    de laCampa, MD
    Sanz-Medel, A
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (01) : 28 - 36
  • [4] Characterization of metal complexes with metallothioneins in the liver of the carp Cyprinus carpio by reversed-phase, HPLC with ICP-MS and electrospray ionization (ESI)-MS
    Infante, HG
    Cuyckens, F
    Van Campenhout, K
    Blust, R
    Claeys, M
    Van Vaeck, L
    Adams, FC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (01) : 159 - 166
  • [5] Characterization of metal complexes with metallothioneins in the liver of the carp Cyprinus carpio by reversed-phase HPLC with ICP-MS and electrospray ionization (ESI)-MS
    Infante, Heidi Goenaga
    Cuyckens, Filip
    Van Campenhout, Karen
    Blust, Ronny
    Claeys, Magda
    Van Vaeck, Luc
    Adams, Freddy C.
    Journal of Analytical Atomic Spectrometry, 2004, 19 (01): : 159 - 166
  • [6] The coupling of capillary electrophoresis to ICP-MS
    Michalke, B
    Schramel, P
    ANALUSIS, 1998, 26 (06) : M51 - M56
  • [7] Characterization of metal glycinate complexes by electrospray Q-TOF-MS/MS and their determination by capillary electrophoresis-ICP-MS: application to premix samples
    Vacchina, Veronique
    Oguey, Sebastien
    Ionescu, Catherine
    Bravo, David
    Lobinski, Ryszard
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (01) : 435 - 449
  • [8] Nanoparticle measurements using single particle ICP-MS and capillary electrophoresis ICP-MS
    Olesik, John
    Jiao, Shi
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [9] Investigation of metal binding by recombinant and native metallothioneins by capillary zone electrophoresis (CZE) coupled with inductively coupled plasma mass spectrometry (ICP-MS) via a self-aspirating total consumption micronebulizer
    Polec, K
    Szpunar, J
    Palacios, O
    Gonzàlez-Duarte, P
    Atrian, S
    Lobinski, R
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (06) : 567 - 574
  • [10] Analysis for metal complexes with metallothionein in rat liver by capillary zone electrophoresis using ICP double-focussing sector-field isotope dilution MS and electrospray MS detection
    Polec-Pawlak, K
    Schaumlöffel, D
    Szpunar, J
    Prange, A
    Lobinski, R
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) : 908 - 912