Modeling Residual Chlorine Response to a Microbial Contamination Event in Drinking Water Distribution Systems

被引:44
|
作者
Helbling, Damian E. [1 ,2 ]
VanBriesen, Jeanne M. [2 ]
机构
[1] Dept Environm Chem, CH-8600 Dubendorf, Switzerland
[2] Carnegie Mellon Univ, Dept Civil & Environm Engn, Pittsburgh, PA 15213 USA
来源
基金
美国国家科学基金会;
关键词
SENSOR PLACEMENT; DISTRIBUTION NETWORKS; CROSS JUNCTIONS; DECAY; DEMAND; SECURITY; KINETICS;
D O I
10.1061/(ASCE)EE.1943-7870.0000080
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Changes in chlorine residual concentrations in water distribution systems could be used as an indicator of microbial contamination. Consideration is given on how to model the behavior of chlorine within the distribution system following a microbial contamination event. Existing multispecies models require knowledge of specific reaction kinetics that are unlikely to be known. A method to parameterize a rate expression describing microbially induced chlorine decay over a wide range of conditions based on a limited number of batch experiments is described. This method is integrated into EPANET-MSX using the programmer's toolkit. The model was used to simulate a series of microbial contamination events in a small community distribution system. Results of these simulations showed that changes in chlorine induced by microbial contaminants can be observed throughout a network at nodes downstream from and distant to the contaminated node. Some factors that promote or inhibit the transport of these chlorine demand signals are species-specific reaction kinetics, the chlorine concentration at the time and location of contamination, and the system's unique demand patterns and architecture.
引用
收藏
页码:918 / 927
页数:10
相关论文
共 50 条
  • [1] Modeling chlorine response to uncontrolled contamination events in drinking water distribution systems
    Mohan, S.
    Abhijith, G. R.
    Aneesh, B.
    JOURNAL OF WATER SUPPLY RESEARCH AND TECHNOLOGY-AQUA, 2018, 67 (08): : 834 - 845
  • [2] Modelling the behaviour of chlorine within a drinking water distribution system following a microbial contamination event
    Macedo, Dhiogo Okumoto
    Janzen, Johannes Gerson
    URBAN WATER JOURNAL, 2022, 19 (05) : 531 - 537
  • [3] Microbial Community Response to Chlorine Conversion in a Chloraminated Drinking Water Distribution System
    Wang, Hong
    Proctor, Caitlin R.
    Edwards, Marc A.
    Pryor, Marsha
    Domingo, Jorge W. Santo
    Ryu, Hodon
    Camper, Anne K.
    Olson, Andrew
    Pruden, Amy
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (18) : 10624 - 10633
  • [4] Modeling Chlorine decay in drinking water distribution systems using aquasim
    Madzivhandila V.A.
    Chirwa E.M.N.
    Chirwa, Evans M. N. (evans.chirwa@up.ac.za), 1600, Italian Association of Chemical Engineering - AIDIC (57): : 1111 - 1116
  • [5] MODELING CHLORINE RESIDUALS IN DRINKING-WATER DISTRIBUTION-SYSTEMS
    ROSSMAN, LA
    CLARK, RM
    GRAYMAN, WM
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1994, 120 (04): : 803 - 820
  • [6] Modeling of Residual Chlorine on Addis Ababa Water Supply Distribution Systems
    Yimer, Tigist
    Desale, Tewodrose
    Asmare, Metafet
    Endris, Seid
    Ali, Alemayehu
    Metaferia, Girum
    WATER CONSERVATION SCIENCE AND ENGINEERING, 2022, 7 (04) : 443 - 452
  • [7] Modeling of Residual Chlorine on Addis Ababa Water Supply Distribution Systems
    Tigist Yimer
    Tewodrose Desale
    Metafet Asmare
    Seid Endris
    Alemayehu Ali
    Girum Metaferia
    Water Conservation Science and Engineering, 2022, 7 : 443 - 452
  • [8] Seawater desalination based drinking water: Microbial characterization during distribution with and without residual chlorine
    Farhat, Nadia
    Kim, Lanhee
    Mineta, Katsuhiko
    Alarawi, Mohammed
    Gojobori, Takashi
    Saikaly, Pascal
    Vrouwenvelder, Johannes
    WATER RESEARCH, 2022, 210
  • [10] Modeling of residual chlorine in water distribution system
    Li, X
    Gu, DM
    Qi, JY
    Ukita, M
    Zhao, HB
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2003, 15 (01) : 136 - 144