Phase-sensitive X-ray imaging of synovial joints

被引:30
|
作者
Li, J. [1 ]
Zhong, Z. [2 ]
Connor, D. [2 ]
Mollenhauer, J. [3 ]
Muehleman, C. [1 ,4 ]
机构
[1] Rush Univ, Med Ctr, Dept Biochem, Chicago, IL 60612 USA
[2] Brookhaven Natl Lab, Natl Synchrotron Light Source, Upton, NY 11973 USA
[3] Univ Tubingen, Nat Sci & Med Inst, Reutlingen, Germany
[4] Rush Univ, Med Ctr, Dept Orthoped Surg, Chicago, IL 60612 USA
关键词
Cartilage imaging; Diffraction Enhanced imaging; Analyzer-based imaging; DIFFRACTION; RADIOGRAPHY; CARTILAGE; TISSUE; KNEE; CT;
D O I
10.1016/j.joca.2009.03.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To test the efficacy of phase-sensitive X-ray imaging for intact synovial joints, whereby refraction effects, along with the attenuation of conventional radiography, can be exploited. Design: Intact cadaveric human knee joints were imaged, in the computed tomographic mode, using an analyzer-based X-ray,system at the National Synchrotron Light Source, Brookhaven National Laboratory. A collimated fan beam of 51 keV X-rays was prepared by a silicon [1,1,1 reflection] double-crystal monochromator. The X-ray beam transmitted through the specimen was imaged after diffraction in the vertical plane by means of the analyzer crystal with the analyzer crystal tuned to its half-reflectivity point (6.5 mu rad). A two-dimensional filtered backprojection (FBP) algorithm was used for reconstructing transverse slices of images. Results: The resulting images demonstrate simultaneous soft tissue and bone contrast at a level that has not been achieved previously. Identifiable structures include articular cartilage, cruciate ligaments, loose connective tissue, menisci, and chondrocalcinosis. Conclusion: Phase-sensitive X-ray imaging using an analyzer-based system renders exceptionally high quality images of soft and hard tissues within synovial joints, with high contrast and resolution, and thus holds promise for the eventual clinical utility. (C) 2009 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1193 / 1196
页数:4
相关论文
共 50 条
  • [1] Phase-sensitive x-ray imaging
    Fitzgerald, R
    PHYSICS TODAY, 2000, 53 (07) : 23 - 26
  • [2] Progress in in-line phase-sensitive x-ray imaging
    Wu, X.
    Liu, H.
    MEDICAL PHYSICS, 2007, 34 (06) : 2517 - 2517
  • [3] Phase-sensitive imaging and phase tomography using X-ray interferometers
    Momose, A
    OPTICS EXPRESS, 2003, 11 (19): : 2303 - 2314
  • [4] PHASE-SENSITIVE X-RAY IMAGING AT THE SYRMEP BEAMLINE OF ELETTRA
    Tromba, G.
    Arfelli, F.
    Castelli, E.
    Dreossi, D.
    Longo, R.
    Mancini, L.
    Menk, R. H.
    Montanari, F.
    Olivo, A.
    Pani, S.
    Rigon, L.
    Zanini, F.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C52 - C52
  • [5] Phase-space evolution of x-ray coherence in phase-sensitive imaging
    Wu, Xizeng
    Liu, Hong
    APPLIED OPTICS, 2008, 47 (22) : E44 - E52
  • [6] Clarification of aspects in in-line phase-sensitive x-ray imaging
    Wu, Xizeng
    Liu, Hong
    MEDICAL PHYSICS, 2007, 34 (02) : 737 - 743
  • [7] X-ray phase-sensitive microscope imaging with a grating interferometer:Theory and simulation
    杨杰成
    朱佩平
    梁栋
    郑海荣
    葛永帅
    Chinese Physics B, 2022, (09) : 738 - 743
  • [8] X-ray phase-sensitive microscope imaging with a grating interferometer: Theory and simulation
    Yang, Jiecheng
    Zhu, Peiping
    Liang, Dong
    Zheng, Hairong
    Ge, Yongshuai
    CHINESE PHYSICS B, 2022, 31 (09)
  • [9] Contrast Mechanism and Origin of Artifacts in Phase-Sensitive X-Ray Volumetric Imaging
    Wu, X.
    Yan, A.
    Liu, H.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [10] Phase-sensitive x-ray imaging (vol 53, pg 23, 2000)
    Fitzgerald, R
    PHYSICS TODAY, 2000, 53 (11) : 82 - 82