New sensor based on fibre optics for measurement of heart movement

被引:4
作者
Hoeland, K
Kloppe, A
Hexamer, M
Nowack, G
Werner, J
机构
[1] Ruhr Univ Bochum, Fac Med, Dept Biomed Engn, Bochum, Germany
[2] Ruhr Univ Bochum, Fac Elect Engn & Informat Sci, Inst Comp Sci, Bochum, Germany
关键词
fibre optic; haemodynamic sensor; cardiac contraction; sensor-controlled pacemaker; defibrillator;
D O I
10.1007/BF02345457
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Innovative fibre-optic sensor technology for measuring the movement of the myocardial walls, and from this the heart chamber volumes, was developed. An optical fibre, with a mirror at its end, is inserted into a catheter located in the heart. An opto-electrical control unit positioned outside the heart contains both the light source and the signal receiver. It generates and couples the light into the fibre and transforms and analyses the reflected signal. With such a system, the movement of the cardiac wall can be continuously measured during each cycle, because the fibre moves synchronously with the heart, and this movement bends the fibre, changing the optical attenuation. Experiments where the fibres were wound around metal cylinders of different diameters revealed a maximum sensitivity of 4% mm(-1) diameter. The noise signal corresponded to about 1% of the diameter. First tests in a working pig heart showed a high correspondence of the fibre signal with cardiac parameters. Although these tests are promising, further long-term, extensive experiments in preclinical test devices, and later in clinical tests, must be carried out before the new sensor is used in clinical practice. The fibre-optic technique could be used in monitoring devices, assist devices, pacemaker systems or cardioverter defibrillators.
引用
收藏
页码:571 / 575
页数:5
相关论文
共 13 条
[1]   HISTORICAL REVIEW OF MICROBEND FIBEROPTIC SENSORS [J].
BERTHOLD, JW .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 1995, 13 (07) :1193-1199
[2]  
Bludau W., 1998, LICHTWELLENLEITER SE
[3]  
Davis C., 1997, Australasian Physical and Engineering Sciences in Medicine, V20, P214
[4]   Cardiokymograph system with a capacitance transducer and its preliminary application in the measurement of heart wall movement [J].
Ge, WQ ;
Luo, ZC ;
Jin, J ;
Huang, YC ;
Wang, S ;
Lui, SJ .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (01) :22-26
[5]  
Geddes L. A., 1989, PRINCIPLES APPL BIOM
[6]  
Gowar J., 1984, OPTICAL COMMUNICATIO
[7]  
HOELAND K, 1999, Patent No. 0009012
[8]  
KLOPPE A, 2000, Z KARDIOL, V89, pA376
[9]  
KLPPPE A, 2000, CARDIOVASC ENG, V5, P46
[10]   MICROBEND FIBEROPTIC SENSOR [J].
LAGAKOS, N ;
COLE, JH ;
BUCARO, JA .
APPLIED OPTICS, 1987, 26 (11) :2171-2180