Echocardiographic Assessment of Right Ventricular Volumes after Surgical Repair of Tetralogy of Fallot: Clinical Validation of a New Echocardiographic Method

被引:43
|
作者
Dragulescu, Andreea [1 ]
Grosse-Wortmann, Lars [1 ,2 ]
Fackoury, Cheryl [1 ]
Riffle, Sonja [3 ]
Waiss, Mary [3 ]
Jaeggi, Edgar [1 ]
Yoo, Shi-Joon [1 ,2 ]
Friedberg, Mark K. [1 ]
Mertens, Luc [1 ]
机构
[1] Hosp Sick Children, Labatt Family Heart Ctr, Div Cardiol, Dept Paediat, Toronto, ON M5G 1X8, Canada
[2] Hosp Sick Children, Dept Diagnost Imaging, Toronto, ON M5G 1X8, Canada
[3] Ventripoint Inc, Seattle, WA USA
关键词
Echocardiography; Cardiac volume; Tetralogy of Fallot; Magnetic resonance imaging; PULMONARY VALVE-REPLACEMENT; 3-DIMENSIONAL ECHOCARDIOGRAPHY; CORRECTED TETRALOGY; DISEASE; OUTCOMES; ADULTS; SIZE;
D O I
10.1016/j.echo.2011.08.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Assessment of right ventricular (RV) volumes and function is important in patients after tetralogy of Fallot (TOF) repair. Currently, cardiac magnetic resonance imaging (MRI) is considered the clinical reference method for RV volume and function measurements. Three-dimensional (3D) knowledge-based reconstruction derived from two-dimensional echocardiographic imaging with magnetic tracking is a novel approach to RV volumetrics. The aim of this study was to assess the feasibility and reliability of this novel echocardiographic technique in patients after TOF repair. The accuracy of the method was assessed by comparison with measurements obtained by cardiac MRI. Methods: Thirty patients (mean age, 13.7 +/- 2.8 years) after TOF repair, referred for cardiac MRI, were included. Immediately after MRI, echocardiographic image acquisition was performed using a standard ultrasound scanner linked to a Ventripoint Medical Systems unit. Echocardiographic and MRI measurements were performed offline. Parameters analyzed were end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction. Intraobserver, interobserver, and intertechnique variability was assessed using Pearson's correlation analysis, coefficients of variation, and Bland-Altman analysis. Results: Echocardiographic two-dimensionally based 3D reconstruction was highly feasible, with low intraobserver and interobserver variability for EDV and slightly higher variability for ESV and ejection fraction. The 3D reconstruction values for EDV, ESV, and ejection fraction were correlated highly with MRI values, with low coefficients of variation. The agreement between both methods was high. Three-dimensional reconstruction slightly underestimated RV volumes, by 2.5% for EDV and 4.6% for ESV compared with MRI volumes. Conclusions: In patients after TOF repair, echocardiographic 3D reconstruction is highly feasible, with good reproducibility for measurements of RV EDV. There is good agreement with MRI measurements, with a small underestimation of RV volumes. The use of this method in clinical practice warrants further investigation. (J Am Soc Echocardiogr 2011; 24: 1191-8.)
引用
收藏
页码:1191 / 1198
页数:8
相关论文
共 50 条
  • [1] Echocardiographic assessment of right ventricular volumes: a comparison of different techniques in children after surgical repair of tetralogy of Fallot
    Dragulescu, Andrea
    Grosse-Wortmann, Lars
    Fackoury, Cheryl
    Mertens, Luc
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (07) : 596 - 604
  • [2] Echocardiographic assessment after surgical repair of tetralogy of Fallot
    Carminati, Mario
    Pluchinotta, Francesca R.
    Piazza, Luciane
    Micheletti, Angelo
    Negura, Diana
    Chessa, Massimo
    Butera, Gianfranco
    Arcidiacono, Carmelo
    Saracino, Antonio
    Bussadori, Claudio
    FRONTIERS IN PEDIATRICS, 2015, 3
  • [3] Correlation of Early Echocardiographic Right Ventricular Dimension and MRI Right Ventricular Volumes Late After Tetralogy of Fallot Repair
    Hussain, Sara
    Al-Radi, Osman
    Pondorfer, Prisca
    Grosse-Wortmann, Lars
    Mertens, Luc
    Van Arsdell, Glen
    CIRCULATION, 2015, 132
  • [4] Echocardiographic findings before and after surgical repair of Tetralogy of Fallot
    Noori, Noor Mohammad
    Mahjoubifard, Maziar
    Alavi, Seyed Mostafa
    Teimouri, Alireza
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2015, 65 (09) : 921 - 927
  • [5] ANGIOGRAPHIC STUDY OF RIGHT VENTRICULAR VOLUMES AFTER SURGICAL REPAIR FOR TETRALOGY OF FALLOT
    CHANTEPIE, A
    DESVEAUX, B
    ROUX, S
    POTTIER, JM
    QUILLET, L
    MARCHAND, M
    RAYNAUD, P
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1989, 82 (05): : 693 - 698
  • [6] Accuracy of echocardiographic assessment of the right ventricle after tetralogy of Fallot repair: Comparison with MRI
    Thiagarajan, R
    Moran, A
    Levine, J
    Powell, A
    Geva, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 453A - 453A
  • [7] ECHOCARDIOGRAPHIC ASSESSMENT OF RIGHT BUNDLE-BRANCH INJURY AFTER REPAIR OF TETRALOGY OF FALLOT
    PICKOFF, AS
    MEHTA, AV
    CASTA, A
    FERRER, PL
    WOLFF, GS
    TAMER, DF
    GARCIA, OL
    GELBAND, H
    CIRCULATION, 1981, 63 (01) : 174 - 180
  • [8] Right Ventricular Remodeling During the First Decade After Tetralogy of Fallot Repair: An Echocardiographic Study
    Galan, Jose
    Jones, Andrea
    Numata, Ryusuke
    Mondal, Antara
    Thomas, Angeli
    Wang, Yan
    DiLorenzo, Michael
    Zavez, Alexis
    Goldmuntz, Elizabeth
    Mercer-Rosa, Laura
    CIRCULATION, 2024, 150
  • [9] ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR FUNCTION FOLLOWING TETRALOGY OF FALLOT REPAIR
    LACORTE, MA
    WILLIAMS, RG
    AMERICAN JOURNAL OF CARDIOLOGY, 1975, 35 (01): : 150 - 150
  • [10] Transesophageal Echocardiographic Predictor of Significant Right Ventricular Outflow Tract Obstruction After Tetralogy of Fallot Repair
    Borodinova, Olga
    Mykychak, Yaroslav
    Yemets, Illya
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2020, 32 (02) : 282 - 289