Noise reduction for low-dose single-slice helical CT sinogram

被引:0
|
作者
Wang, J [1 ]
Li, TF [1 ]
Lu, HB [1 ]
Liang, ZR [1 ]
机构
[1] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Helical computed tomography (HCT) offers several advantages on conventional step-and-shoot CT for imaging a relatively large object, especially in dynamic studies. However, it may increase the x-ray exposure significantly. This work aims to reduce the radiation by noise reduction on low-dose (or mA) sinogram of HCT. The noise reduction method is based on three observations on HCT: (1) the axial sampling of HCT projections is nearly continuous as the detector system rotates; (2) the noise distribution in the sinogram space is nearly a Gaussian after system calibration (including logarithmic transform); and (3) the relationship of calibrated data mean and variance can be expressed as an exponential functional across the field-of-view. Based on the second and third observations, a penalized weighted least-square (PWLS) solution was chosen, where the weight is given by the data mean-variance relationship. The first observation encourages the use of Karhunen-Loeve (KL) strategy along the axial direction. In the KL domain, the eigenvalue of each principal component was used for an adaptive noise smoothing via the penalty. The KL-PWLS noise-reduction method was implemented analytically for efficient reconstruction of large volume HCT images. Simulation studies demonstrated noticeable improvement, in terms of image quality measures and abnormal detectability observer studies, of the proposed noise-reduction method over conventional low-pass noise filtering with an optimal cutoff frequency and/or other filter parameters.
引用
收藏
页码:2769 / 2773
页数:5
相关论文
共 50 条
  • [1] Noise reduction for low-dose single-slice helical CT sinograms
    Wang, Jing
    Li, Tianfang
    Lu, Hongbing
    Liang, Zhengrong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1230 - 1237
  • [2] Noise Estimation for Single-Slice Sinogram of Low-Dose X-Ray Computed Tomography Using Homogenous Patch
    Liao, Zhiwu
    Hu, Shaoxiang
    Li, Ming
    Chen, Wufan
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2012, 2012
  • [3] Noise reduction for low-dose CT sinogram based on fuzzy entropy
    Liu, Yi
    Zhang, Quan
    Gui, Zhi-Guo
    Dianzi Yu Xinxi Xuebao/Journal of Electronics and Information Technology, 2013, 35 (06): : 1421 - 1427
  • [4] Multiscale Noise Reduction on Low-Dose CT Sinogram by Stationary Wavelet Transform
    Jiao, Chun
    Wang, Dongming
    Lu, Hongbing
    Zhang, Zhu
    Liang, Jerome Z.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4605 - +
  • [5] Sinogram noise reduction for low-dose CT by statistics-based nonlinear filters
    Wang, J
    Lu, HB
    Li, TF
    Liang, ZR
    MEDICAL IMAGING 2005: IMAGE PROCESSING, PT 1-3, 2005, 5747 : 2058 - 2066
  • [6] CAD system for lung cancer screening using low-dose single-slice CT images
    Kubo, M
    Yamada, N
    Kawata, Y
    Niki, N
    Eguchi, K
    Ohmatsu, H
    Kakinuma, R
    Kaneko, M
    Kusumoto, M
    Nishiyama, N
    Moriyama, N
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 819 - 826
  • [7] Radiation dose from helical CT in children: Comparison of multi-slice and single-slice protocols
    Frush, DP
    Yoshizumi, TT
    Paulson, EK
    Johnson, GA
    RADIOLOGY, 2001, 221 : 246 - 246
  • [8] Noise reduction for low-dose helical CT by fully 3D penalized weighted least-squares sinogram smoothing
    Wang, Jing
    Li, Tianfang
    Lu, Hongbing
    Liang, Zhengrong
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [9] Anti-aliasing weighting functions for single-slice helical CT
    La Rivière, PJ
    Pan, XC
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (08) : 978 - 990
  • [10] Single-slice rebinning method for helical cone-beam CT
    Noo, F
    Defrise, M
    Clackdoyle, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (02): : 561 - 570