Determination of reboxetine in rat brain microdialysates and plasma samples using liquid chromatography coupled to fluorescence detection

被引:3
|
作者
Shraim, Naser [1 ]
Clinckers, Ralph [1 ]
Sarre, Sophie [1 ]
Michotte, Yvette [1 ]
Van Eeckhaut, Ann [1 ]
机构
[1] Vrije Univ Brussel, Ctr Neurosci, Dept Pharmaceut Chem & Drug Anal, B-1090 Brussels, Belgium
关键词
Reboxetine; Liquid chromatography; Fluorescence detection; Intracerebral microdialysis; Plasma; Rat; SOLID-PHASE EXTRACTION; 9-FLUORENYLMETHYL CHLOROFORMATE; REUPTAKE INHIBITOR; MASS-SPECTROMETRY; HUMAN-SERUM; DRUG; ANTIDEPRESSANTS; DERIVATIZATION; ENANTIOMERS; ANTIPSYCHOTICS;
D O I
10.1016/j.jchromb.2012.04.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatographic method with fluorescence detection was developed and validated for the quantification of the antidepressant reboxetine (RBX), a selective noradrenalin reuptake inhibitor, in rat brain microdialysates. After modification of the method in terms of sample preparation and sensitivity, it was also validated for the quantification of RBX in rat plasma samples. To enable fluorescence detection, a pre-column derivatization step with 9-fluorenylmethyl chloroformate was included. Separations were performed on a reversed phase C-18 column using gradient elution. The retention time for RBX was found to be 8.8 min. The assay of RBX in brain microdialysis samples showed a linear relationship in the calibration curve from 2 to 200 ng/mL, with a correlation coefficient >= 0.999. The limit of detection (LOD) and the lower limit of quantification (LLOQ) were 0.6 and 2.0 ng/mL respectively. The intra-day and the inter-day precision (RSD %) ranged between 1.5% and 11.7% with an average recovery of 101.2 +/- 8.2% (mean +/- SD, n =40). For the analysis of plasma samples, the calibration curve was linear between 20 and 700 ng/mL with a correlation coefficient >= 0.999. LOD and LLOQ were 6 and 20 ng/mL respectively. The intra-day and the inter-day precision (RSD %) ranged between 1.7% and 11.5% with an average recovery of 98.5 +/- 7.3% (mean +/- SD, n = 40). We demonstrated the applicability of the method to determine the concentration time profiles of RBX in brain and plasma following systemic administration. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:53 / 61
页数:9
相关论文
共 50 条
  • [1] Determination of fluoxetine, norfluoxetine and their enantiomers in rat plasma and brain samples by liquid chromatography with fluorescence detection
    Unceta, Nora
    Barrondo, Sergio
    Ruiz de Azua, Inigo
    Gomez-Caballero, Alberto
    Aranzazu Goicolea, M.
    Salles, Joan
    Barrio, Ramon J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 519 - 528
  • [2] Determination of amino acids associated with cerebral ischaemia in rat brain microdialysates using narrowbore liquid chromatography and fluorescence detection
    Van Hemelrijek, A
    Sarre, S
    Smolders, I
    Michotte, Y
    JOURNAL OF NEUROSCIENCE METHODS, 2005, 144 (01) : 63 - 71
  • [3] Determination of glutamate in rat brain microdialysates by microbore liquid chromatography with electrochemical detection
    Tsai, TH
    Matthews, K
    Dalley, JW
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1997, 20 (18) : 3039 - 3047
  • [4] High performance liquid chromatography with fluorescence detection for the determination of phenylpropanolamine in human plasma and rat's blood and brain microdialysates using DIB-Cl as a label
    Kaddoumi, A
    Mori, T
    Nakashima, MN
    Wada, M
    Nakashima, K
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (03) : 643 - 650
  • [5] Critical evaluation of acetylcholine determination in rat brain microdialysates using ion-pair liquid chromatography with amperometric detection
    De Bundel, Dimitri
    Sarre, Sophie
    Van Eeckhaut, Ann
    Smolders, Ilse
    Michotte, Yvette
    SENSORS, 2008, 8 (08) : 5171 - 5185
  • [6] Determination of Ochratoxin-A in the brain microdialysates and plasma of awake, freely moving rats using ultra high performance liquid chromatography fluorescence detection method
    Kaya, Elif Mine Oncu
    Korkmaz, Orhan Tansel
    Ugur, Duygu Yeniceli
    Sener, Erol
    Tuncel, A. Nese
    Tuncel, Muzaffer
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1125
  • [7] Simultaneous determination of oleuropein and hydroxytyrosol in rat plasma using liquid chromatography with fluorescence detection
    Tan, HW
    Tuck, KL
    Stupans, I
    Hayball, PJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (01): : 187 - 191
  • [8] Determination of marbofloxacin in plasma samples by high-performance liquid chromatography using fluorescence detection
    Garcia, MA
    Solans, C
    Aramayona, JJ
    Rueda, S
    Bregante, MA
    JOURNAL OF CHROMATOGRAPHY B, 1999, 729 (1-2): : 157 - 161
  • [9] Determination of plasma ziprasidone using liquid chromatography with fluorescence detection
    Suckow, RF
    Fein, M
    Correll, CU
    Cooper, TB
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 799 (02): : 201 - 208
  • [10] Simultaneous measurement of blood and brain microdialysates of granisetron in rat by high-performance liquid chromatography with fluorescence detection
    Huang, C
    Chen, KC
    Chen, CF
    Tsai, TH
    JOURNAL OF CHROMATOGRAPHY B, 1998, 716 (1-2): : 251 - 255