Methodology for load matching and optimization of directly coupled PV pumping systems

被引:0
|
作者
Balouktsis, I. [1 ]
Karapantsios, T. D. [2 ]
Chassapis, D. [3 ]
David, K. [3 ]
Anastasiou, K. [4 ]
Balouktsis, A. [3 ]
机构
[1] Univ Loughborough, Dept Elect & Elect Engn, Loughborough, Leics, England
[2] Aristotle Univ Thessaloniki, Div Chem Technol, Thessaloniki 54124, Greece
[3] Inst Educ Technol Serres, Serres 62124, Greece
[4] Inst Educ Technol Lamia, Lamia 35100, Greece
关键词
PV; water pumping systems; load matching; optimization;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The aim of this work is to develop a methodology for the assessment of load matching and further estimation of the optimum photovoltaic (PV) arrays arrangement for water pumping systems over a prolonged period of time. The method calls for the calculation of the appropriate effectiveness factor defined as the ratio of the load energy over the maximum energy that can be produced by the PV array for a specific time period. The effectiveness factor depends on the PV array characteristics, the load characteristics, and the solar irradiance conditions. To produce realistic predictions for the effectiveness factor and the PV arrays arrangement with validity over long periods of time, the present model takes into account the stochastic variation of solar irradiation over a long period of time and not just a fixed diurnal variation as was traditionally done in the past. In order to generalize the analysis, simulation results must be presented in a reduced form based on the values of the voltage and current corresponding to the maximum power of the PV array. The results can be expressed in multiple-curve comprehensive plots, which allow determining the optimum photovoltaic array panel's arrangement without engaging sophisticated mathematical calculations.
引用
收藏
页码:227 / +
页数:2
相关论文
共 50 条
  • [1] New approaches on the optimization of directly coupled PV pumping systems
    Firatoglu, ZA
    Yesilata, B
    SOLAR ENERGY, 2004, 77 (01) : 81 - 93
  • [2] MULTI-STEP OPTIMIZATION OF THE DIRECTLY-COUPLED PV PUMPING SYSTEMS
    Firatoglu, Zeynel Abidin
    Yesilata, Blent
    SIGMA JOURNAL OF ENGINEERING AND NATURAL SCIENCES-SIGMA MUHENDISLIK VE FEN BILIMLERI DERGISI, 2005, 23 (01): : 53 - 67
  • [3] DYNAMIC PERFORMANCE OF A DIRECTLY COUPLED PV PUMPING SYSTEM
    ANIS, WR
    METWALLY, HMB
    SOLAR ENERGY, 1994, 53 (04) : 369 - 377
  • [4] Performance of a directly-coupled PV water pumping system
    Mokeddem, Abdelmalek
    Midoun, Abdelhamid
    Kadri, D.
    Hiadsi, Said
    Raja, Iftikhar A.
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (10) : 3089 - 3095
  • [5] Soft Computing Modelling of a Directly Coupled PV Water Pumping System
    Elsonbaty, Nadia A.
    Enany, Mohamed A.
    Gamil, Mahmoud M.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2016, 6 (01): : 99 - 105
  • [6] Dynamic behavior of water wells coupled to PV pumping systems
    Fraidenraich, N.
    Vilela, O. C.
    PROGRESS IN PHOTOVOLTAICS, 2007, 15 (04): : 317 - 330
  • [7] A NONLINEAR OPTIMIZATION APPROACH TO THE LOAD-MATCHING OF STAND-ALONE PV POWER-SYSTEMS
    KHOUZAM, KY
    GROUMPOS, PP
    CONFERENCE RECORD OF THE TWENTIETH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE - 1988, VOLS 1-2, 1988, : 1298 - 1303
  • [8] Optimization of A Directly Coupled PV Water Pump for Irrigation Purposes: Bangladesh Perspective
    Sabah, Sanjida Hossain
    Rahman, Md Mosaddequr
    Islam, Mohaimenul
    INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND ENERGY TECHNOLOGIES (ICECET 2021), 2021, : 1343 - 1348
  • [9] PERFORMANCE MATCHING AND OPTIMIZATION OF WIND POWERED WATER PUMPING SYSTEMS
    BRAGG, GM
    SCHMIDT, WL
    ENERGY CONVERSION, 1979, 19 (01): : 33 - 39
  • [10] Simulation of PV pumping systems
    Davis, M.
    Journal of Energy in Southern Africa, 1994, 5 (03) : 73 - 78