Development of a FBG probe for non-invasive carotid pulse waveform assessment

被引:3
|
作者
Leitao, C. [1 ]
Bilro, L. [2 ]
Alberto, N. [2 ]
Antunes, P. [1 ,2 ]
Lima, H. [1 ]
Andre, P. S. [2 ]
Nogueira, R. [2 ]
Pinto, J. L. [1 ,2 ]
机构
[1] Univ Aveiro, Dept Phys, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[2] Campus Univ Santiago, Inst Telecommun, P-3810193 Aveiro, Portugal
关键词
Fibre Bragg sensor; hemodynamics; pulse wave analysis; augmentation index; ARTERIAL STIFFNESS; PRESSURE;
D O I
10.1117/12.923560
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
One of the early predictors of cardiovascular diseases, with growing interest, is the arterial stiffness which is typically evaluated through the velocity and morphology of the arterial pressure wave. In each cardiac cycle the heart generates a pressure wave which propagates through the arterial tree. Along its path, the pressure wave interacts with the arterial walls and, consequently, the morphology of a local arterial pressure wave can be assessed by the arterial distention movement. Due to its superficiality, proximity of the heart and high probability of atherosclerosis development, the carotid artery has particular interest to be monitored. In this work, the development of a non-invasive fibre Bragg grating (FBG) probe for the acquisition of the arterial distention wave is presented. Comparing to traditional methods, optical FBG based sensors can offer many advantages, namely, compactness, immunity to electromagnetic interference, high sensitivity, low noise and immunity to light source intensity due to its codification in the wavelength domain. The arterial movements induce strain on a uniform FBG, with the arterial distention pattern. The carotid pulse wave was successful accessed in young human carotid artery, with an acquisition rate of 950 Hz, allowing a clear distinction of the carotid pulse identification points.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] NON-INVASIVE ASSESSMENT OF CAROTID CIRCULATION
    WARNER, JS
    JOURNAL OF THE TENNESSEE MEDICAL ASSOCIATION, 1982, 75 (10): : 662 - 667
  • [2] EXTERNAL CAROTID PULSE TRACINGS - VALUE IN THE NON-INVASIVE ASSESSMENT OF ARTERIAL ELASTICITY
    MEYERHEINE, A
    ANSQUER, JC
    GESLIN, P
    LAGRUE, G
    ANNALES DE MEDECINE INTERNE, 1985, 136 (06): : 529 - 529
  • [3] FOURIER WAVEFORM AMPLITUDE DISTRIBUTION USING A NOVEL NON-INVASIVE METHOD OF RETINAL VASCULAR PULSE WAVEFORM ASSESSMENT
    Abdul-Rahman, Anmar
    Morgan, William H.
    Hazelton, Martin L.
    Betz-Stablein, Brigid
    Yu, Dao-Yi
    Chan, Geoff
    Lam, Jonathon
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 : 136 - 136
  • [4] Fourier Waveform Amplitude Distribution Using A Novel Non-Invasive Method of Retinal Vascular Pulse Waveform Assessment
    Abdul-Rahman, Anmar
    Morgan, Bill
    Hazelton, Martin
    Betz-Stablein, Brigid
    Yu, Dao-Yi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [5] Development of non-invasive vascular elastography for carotid artery plaque assessment
    Schmitt, C
    Cloutier, G
    Maurice, RL
    Lanthier, S
    Giroux, MF
    Soulez, G
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 393 - 396
  • [6] Feasibility studies of Bragg probe for noninvasive carotid pulse waveform assessment
    Leitao, Catia
    Bilro, Lucia
    Alberto, Nelia
    Antunes, Paulo
    Lima, Hugo
    Andre, Paulo S.
    Nogueira, Rogerio
    Pinto, Joao L.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (01)
  • [7] Acquisition of Jugular Venous Pulse Waveform by a Non-invasive Technique
    Bagyaraj, S.
    Ragumathulla, M.
    Vaithiyanathan, D.
    RECENT ADVANCES IN MECHANICAL ENGINEERING, NCAME 2019, 2020, : 343 - 352
  • [8] An ultrasound automated method for non-invasive assessment of carotid artery pulse wave velocity
    Zardi, Enrico Maria
    Di Geso, Luca
    Afeltra, Antonella
    Zardi, Domenico Maria
    Giorgi, Chiara
    Salaffi, Fausto
    Carotti, Marina
    Gutierrez, Marwin
    Filippucci, Emilio
    Grassi, Walter
    JOURNAL OF INVESTIGATIVE MEDICINE, 2018, 66 (06) : 973 - 979
  • [9] A NOVEL METHOD OF NON-INVASIVE RETINAL VASCULAR PULSE WAVEFORM ASSESSMENT USING FOURIER ANALYSIS
    Abdul-Rahman, Anmar
    Morgan, William
    Hazelton, Martin
    Betz-Stablein, Brigid
    Yu, Dao-Yi
    Chan, Geoff
    Lam, Jonathan
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 : 99 - 99
  • [10] NON-INVASIVE ASSESSMENT OF CAROTID-ARTERY DISEASE
    BANDYK, DF
    THIELE, BL
    WESTERN JOURNAL OF MEDICINE, 1983, 139 (04): : 486 - 501