AUTOMATIC BONE LOCALIZATION AND FRACTURE DETECTION FROM VOLUMETRIC ULTRASOUND IMAGES USING 3-D LOCAL PHASE FEATURES

被引:34
|
作者
Hacihaliloglu, Ilker [1 ]
Abugharbieh, Rafeef [1 ]
Hodgson, Antony J. [2 ]
Rohling, Robert N. [1 ,2 ]
Guy, Pierre [3 ]
机构
[1] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V6T 1Z4, Canada
[2] Univ British Columbia, Dept Mech Engn, Vancouver, BC V6T 1Z4, Canada
[3] Univ British Columbia, Dept Orthopaed, Vancouver, BC V6T 1Z4, Canada
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2012年 / 38卷 / 01期
基金
加拿大自然科学与工程研究理事会;
关键词
Ultrasound; Local phase features; Phase symmetry; Bone localization; 3-D segmentation; Log Gabor filters; Orthopaedic surgery; REGISTRATION; SURFACE;
D O I
10.1016/j.ultrasmedbio.2011.10.009
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This article presents a novel method for bone segmentation from three-dimensional (3-D) ultrasound images that derives intensity-invariant 3-D local image phase measures that are then employed for extracting ridge-like features similar to those that occur at soft tissue/bone interfaces. The main contributions in this article include: (1) the extension of our previously proposed phase-symmetry-based bone surface extraction from two-dimensional (2-D) to 3-D images using 3-D Log-Gabor filters; (2) the design of a new framework for accuracy evaluation based on using computed tomography as a gold standard that allows the assessment of surface localization accuracy across the entire 3-D surface; (3) the quantitative validation of accuracy of our 3-D phase-processing approach on both intact and fractured bone surfaces using phantoms and ex vivo 3-D ultrasound scans; and (4) the qualitative validation obtained by scanning emergency room patients with distal radius and pelvis fractures. We show a 41% improvement in surface localization error over the previous 2-D phase symmetry method. The results demonstrate clearly visible segmentations of bone surfaces with a localization accuracy of <0.6 mm and mean errors in estimating fracture displacements below 0.6 mm. The results show that the proposed method is successful even for situations when the bone surface response is weak due to shadowing from muscle and fascia interfaces above the bone, which is a situation where the 2-D method fails. (E-mail: rafeef@ece.ubc.ca) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:128 / 144
页数:17
相关论文
共 50 条
  • [1] Bone Segmentation and Fracture Detection in Ultrasound Using 3D Local Phase Features
    Hacihaliloglu, Ilker
    Abugharbieh, Rafeef
    Hodgson, Antony
    Rohling, Robert
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT I, PROCEEDINGS, 2008, 5241 : 287 - +
  • [2] Automatic Bone Segmentation in Ultrasound Images Using Local Phase Features and Dynamic Programming
    Jia, R.
    Mellon, S. J.
    Hansjee, S.
    Monk, A. P.
    Murray, D. W.
    Noble, J. A.
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 1005 - 1008
  • [3] Automatic Tumor Detection in Automated 3-D Breast Ultrasound Using Local Phase Information
    Wang, Xin
    Guo, Yi
    Wang, Yuanyuan
    2015 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI), 2015, : 68 - 72
  • [4] Automatic registration of 3-D ultrasound images
    Department of Engineering, University of Cambridge, Cambridge, United Kingdom
    不详
    Ultrasound Med. Biol., 6 (841-854):
  • [5] Automatic registration of 3-D ultrasound images
    Rohling, RN
    Gee, AH
    Berman, L
    SIXTH INTERNATIONAL CONFERENCE ON COMPUTER VISION, 1998, : 298 - 303
  • [6] Automatic registration of 3-D ultrasound images
    Rohling, RN
    Gee, AH
    Berman, L
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (06): : 841 - 854
  • [7] Registering Preprocedure Volumetric Images With Intraprocedure 3-D Ultrasound Using an Ultrasound Imaging Model
    King, A. P.
    Rhode, K. S.
    Ma, Y.
    Yao, C.
    Jansen, C.
    Razavi, R.
    Penney, G. P.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (03) : 924 - 937
  • [8] Automatic Segmentation of Antenatal 3-D Ultrasound Images
    Anquez, Jeremie
    Angelini, Elsa D.
    Grange, Gilles
    Bloch, Isabelle
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (05) : 1388 - 1400
  • [9] Automatic Detection of the Carotid Artery Location from Volumetric Ultrasound Images Using Anatomical Position-Dependent LBP Features
    Kawai, Fumi
    Kondo, Satoshi
    Hayata, Keisuke
    Ohmiya, Jun
    Ishikawa, Kiyoko
    Yamamoto, Masahiro
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2015, E98D (07): : 1353 - 1364
  • [10] Fully Automatic Detection of the Carotid Artery from Volumetric Ultrasound Images Using Anatomical Position-Dependent LBP Features
    Kawai, Fumi
    Hayata, Keisuke
    Ohmiya, Jun
    Kondo, Satoshi
    Ishikawa, Kiyoko
    Yamamoto, Masahiro
    MACHINE LEARNING IN MEDICAL IMAGING (MLMI 2013), 2013, 8184 : 41 - 48