Conditions for Limiting the Output Voltage of Double-circuit Semiconductor Discharge Installations with Positive Voltage Feedback

被引:0
|
作者
Suprunovska, Nataliia [1 ]
Shcherba, Anatolii [1 ]
机构
[1] NAS Ukraine, Dept Elect Power Supply Technol Syst, Inst Electrodynam, Kiev, Ukraine
关键词
reservoir capacitor; charge; discharge; transient; positive voltage feedback; charge voltage limitation;
D O I
10.1109/cpee47179.2019.8949171
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The analysis of interrelated repetitive charge-discharge processes in the circuits of the reservoir capacitor of electric-discharge installations with positive voltage feedback is carried out. The regularities of increasing the charge voltage of capacitor during multiple cycles of its charge from the shaper of direct voltage and subsequent discharge of the capacitor through the load are determined. It has been substantiated that the output voltage of electric-discharge installations with positive feedback is limited in magnitude (due to energy losses in their circuits). The limiting voltages of the charge and discharge of the capacitor, the required number of cycles and the time to achieve limiting output voltage of the installation with the required accuracy are determined.
引用
收藏
页码:223 / 226
页数:4
相关论文
共 50 条
  • [1] Fault Location For Double-Circuit Lines Utilizing Sparse Voltage Measurements
    Kang, Ning
    Liao, Yuan
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 1158 - 1164
  • [2] Reed switch protection of double-circuit lines without current and voltage transformers
    Kletsel, M. Ya.
    Mashrapov, B. E.
    Mashrapova, R. M.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 154
  • [3] Investigation of the secondary arc current and the recovery voltage on a double-circuit transmission lines
    Shang, LQ
    Shi, W
    2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, 2004, : 1209 - 1213
  • [4] METHOD FOR VOLTAGE CONTROL IN CHARGE CIRCUIT OF ELECTRIC DISCHARGE INSTALLATIONS WITH TWO CAPACITORS UNDER NONZERO INITIAL CONDITIONS
    Suprunovska, N., I
    Shcherba, M. A.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2018, (05) : 39 - 43
  • [5] ELECTRICAL PARAMETERS OF DOUBLE-CIRCUIT 3-PHASE HIGH VOLTAGE AERIAL LINES
    GESZTI, OP
    ROZSA, L
    PERIODICA POLYTECHNICA-ELECTRICAL ENGINEERING, 1968, 12 (03): : 285 - &
  • [6] Suppression measures for induced voltage and current of deicer of UHV double-circuit transmission line
    Yu, Zhanqing
    Guo, Zhichong
    Lu, Jiazheng
    Tan, Yanjun
    He, Jinliang
    Hu, Jun
    Gaodianya Jishu/High Voltage Engineering, 2014, 40 (05): : 1332 - 1338
  • [7] Calculation and Analysis of the Coupling Effects of the Ultra High Voltage Double-circuit Transmission Lines
    Sun, Qiuqin
    Wang, Guan
    Li, Qingmin
    Li, Qingquan
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 366 - 370
  • [8] Phase current asymmetry on the double-circuit very high voltage overhead transmission line
    Nazarcik, Tomas
    Rawn, Barry
    2016 17TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2016, : 80 - 84
  • [9] Double-Circuit Transmission-Line Fault Location With the Availability of Limited Voltage Measurements
    Kang, Ning
    Liao, Yuan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (01) : 325 - 336
  • [10] Transient analysis in circuits of electric discharge installations with voltage feedback taking into account the recovery time of locking properties their semiconductor switches
    Shcherba A.A.
    Suprunovska N.I.
    Shcherba M.A.
    Suprunovska, N.I. (iednat1@gmail.com), 2018, Institute of Electrodynamics, National Academy of Sciences of Ukraine (2018): : 43 - 47