Three-dimensional reconstruction of mitral eccentric regurgitation from color Doppler flow images

被引:0
|
作者
Liu, Q [1 ]
Wang, LJ [1 ]
Wang, TF [1 ]
Zheng, CQ [1 ]
Zheng, Y [1 ]
机构
[1] Sichuan Univ, Dept Biomed Engn, Chengdu 610065, Peoples R China
关键词
3D reconstruction; interpolation; rendering; mitral eccentric regurgitation;
D O I
10.1117/12.538971
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Advances in echocardiographic systems and computer applications have made three dimensional reconstruction of anatomical structures possible which open a new and fascinating field of color Doppler flow image, but the spatial shape and quantitative evaluation of mitral eccentric regurgitation is often difficult in the clinical setting. In this paper, we present a method to complete the 3D reconstruction of the mitral eccentric regurgitation, mitral eccentric regurgitation information was first derived from color Doppler flow images, and then the mitral eccentric regurgitation velocity values was mapped according to the color bar in the images. With the proper method of interpolation and rendering, the experiment result of 3D visualization of mitral eccentric regurgitation is satisfying, Measurements from a 3D reconstructed flow convergence region may be superior to measurements from 2D color Doppler recordings to calculate volume flow, 3D mitral eccentric regurgitation reconstruction is possible and opens new possibilities in flow quantification, Further study of the method may be very helpful in the diagnosis of heart diseases.
引用
收藏
页码:199 / 202
页数:4
相关论文
共 50 条
  • [1] Three-dimensional reconstruction of mitral regurgitation velocity modality from color Doppler flow images
    Qi, L
    Hong, T
    Fu, WT
    Li, R
    Yi, Z
    WAVELET ANALYSIS AND ITS APPLICATIONS, AND ACTIVE MEDIA TECHNOLOGY, VOLS 1 AND 2, 2004, : 958 - 962
  • [2] Quantitative analysis of mitral eccentric regurgitation jet based on real-time three-dimensional color Doppler flow images
    Qi, L
    Ge, YN
    Fu, WT
    Li, R
    Wavelet Analysis and Active Media Technology Vols 1-3, 2005, : 779 - 782
  • [3] Voxel reconstruction of mitral regurgitation flow jet from color Doppler images
    Li, XN
    Munt, B
    Martin, RW
    Sheehan, FH
    Sivarajan, M
    Leotta, DF
    Bashein, G
    Otto, CM
    CIRCULATION, 1996, 94 (08) : 2881 - 2881
  • [4] Comparison of Intraoperative Three-Dimensional Doppler Color Flow Mapping to Assess Mitral Regurgitation
    Hien, Maximilian D.
    Weymann, Alexander
    Rauch, Helmut
    Grossgasteiger, Manuel
    Motsch, Johann
    Rosendal, Christian
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (07): : 849 - 857
  • [5] Dynamic three-dimensional color flow Doppler: An improved technique for the assessment of mitral regurgitation
    Sugeng, L
    Spencer, KT
    Mor-Avi, V
    DeCara, JM
    Bednarz, JE
    Weinert, L
    Korcarz, CE
    Lammertin, G
    Balasia, B
    Jayakar, D
    Jeevanandam, V
    Lang, RM
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2003, 20 (03): : 265 - 273
  • [6] Three-dimensional echocardiographic reconstruction of mitral valve color Doppler flow events
    Irvine, T
    Derrick, G
    Morris, D
    Norton, M
    Kenny, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (09): : 1103 - +
  • [7] Three-dimensional color Doppler: A clinical study in patients with mitral regurgitation
    De Simone, R
    Glombitza, G
    Vahl, CF
    Albers, J
    Meinzer, HP
    Hagl, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) : 1646 - 1654
  • [8] Three-dimensional color Doppler for assessing mitral regurgitation during valvuloplasty
    De Simone, R
    Glombitza, G
    Vahl, CF
    Albers, J
    Meinzer, HP
    Hagl, S
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 15 (02) : 127 - 133
  • [9] Real-time dynamic three-dimensional color flow Doppler assessment of mitral regurgitation
    Doddamani, S
    Keane, MG
    Frankel, DS
    Fishman, L
    Hungler, E
    Plappert, T
    Sutton, J
    Wiegers, SE
    CIRCULATION, 2004, 110 (17) : 571 - 571
  • [10] Three-dimensional Doppler for the assessment of mitral regurgitation
    De Simone, R
    Glombitza, G
    Vahl, CF
    Albers, J
    Meinzer, HP
    Hagl, S
    COMPUTERS IN CARDIOLOGY 1998, VOL 25, 1998, 25 : 617 - 620