DESIGN OPTIMIZATION OF RADIATION SHIELDING STRUCTURE FOR LEAD SLOWING-DOWN SPECTROMETER SYSTEM

被引:10
|
作者
Kim, Jeong Dong [1 ]
Ahn, Sangjoon [1 ]
Lee, Yong Deok [1 ]
Park, Chang Je [2 ]
机构
[1] Korea Atom Energy Res Inst, Nonproliferat Syst Res Div, Taejon 305353, South Korea
[2] Sejong Univ, Dept Nucl Engn, Seoul 143747, South Korea
关键词
Concrete; High-density polyethylene-Borax; Isotopic assay; Lead slowing-down spectrometer facility; Radiation shielding; Spent nuclear fuel;
D O I
10.1016/j.net.2015.01.004
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A lead slowing-down spectrometer (LSDS) system is a promising nondestructive assay technique that enables a quantitative measurement of the isotopic contents of major fissile isotopes in spent nuclear fuel and its pyroprocessing counterparts, such as U-235, Pu-239, Pu-241, and, potentially, minor actinides. The LSDS system currently under development at the Korea Atomic Energy Research Institute (Daejeon, Korea) is planned to utilize a high-flux (>10(12) n/cm(2).s) neutron source comprised of a high-energy (30 MeV)/high-current (similar to 2 A) electron beam and a heavy metal target, which results in a very intense and complex radiation field for the facility, thus demanding structural shielding to guarantee the safety. Optimization of the structural shielding design was conducted using MCNPX for neutron dose rate evaluation of several representative hypothetical designs. In order to satisfy the construction cost and neutron attenuation capability of the facility, while simultaneously achieving the aimed dose rate limit (<0.06 mu Sv/h), a few shielding materials [high-density polyethylene (HDPE)-Borax, B4C, and Li2CO3] were considered for the main neutron absorber layer, which is encapsulated within the double-sided concrete wall. The MCNP simulation indicated that HOPE-Borax is the most efficient among the aforementioned candidate materials, and the combined thickness of the shielding layers should exceed 100 cm to satisfy the dose limit on the outside surface of the shielding wall of the facility when limiting the thickness of the HOPE-Borax intermediate layer to below 5 cm. However, the shielding wall must include the instrumentation and installation holes for the LSDS system. The radiation leakage through the holes was substantially mitigated by adopting a zigzag-shape with concrete covers on both sides. The suggested optimized design of the shielding structure satisfies the dose rate limit and can be used for the construction of a facility in the near future. Copyright (C) 2015, Published by Elsevier Korea LLC on behalf of Korean Nuclear Society.
引用
收藏
页码:380 / 387
页数:8
相关论文
共 50 条
  • [1] LEAD SLOWING-DOWN SPECTROMETER RESEARCH AT LANSCE
    Haight, R. C.
    Bredeweg, T. A.
    Devlin, M.
    Gavron, A.
    Jandel, M.
    O'Donnell, J. M.
    Wender, S. A.
    Belier, G.
    Granier, T.
    Laurent, B.
    Taieb, J.
    Danon, Y.
    Thompson, J. T.
    CAPTURE GAMMA-RAY SPECTROSCOPY AND RELATED TOPICS, 2013, : 244 - 253
  • [2] First measurements with a lead slowing-down spectrometer at LANSCE
    Rochman, D
    Haight, RC
    Wender, SA
    O'Donnell, JM
    Michaudon, A
    Huff, K
    Vieira, DJ
    Bond, E
    Rundberg, RS
    Kronenberg, A
    Wilhelmy, J
    Bredeweg, TA
    Schwantes, J
    Ethvignot, T
    Granier, T
    Petit, A
    Danon, Y
    INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, PTS 1 AND 2, 2005, 769 : 736 - 739
  • [3] Isotopic Fissile Assay of Spent Fuel in a Lead Slowing-Down Spectrometer System
    Lee, Yongdeok
    Jeon, Juyoung
    Park, Changje
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2017, 49 (03) : 549 - 555
  • [4] Characteristics of a lead slowing-down spectrometer coupled to the LANSCE accelerator
    Rochman, D
    Haight, RC
    O'Donnell, JM
    Michaudon, A
    Wender, SA
    Vieira, DJ
    Bond, EM
    Bredeweg, TA
    Kronenberg, A
    Wilhelmy, JB
    Ethvignot, T
    Granier, T
    Petit, M
    Danon, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 550 (1-2): : 397 - 413
  • [5] Measurements with the high flux lead slowing-down spectrometer at LANL
    Danon, Y.
    Romano, C.
    Thompson, J.
    Watson, T.
    Haight, R. C.
    Wender, S. A.
    Vieira, D. J.
    Bond, E.
    WilhelMy, J. B.
    O'Donnell, J. M.
    Michaudon, A.
    Bredeweg, T. A.
    Schurman, T.
    Rochman, D.
    Granier, T.
    Ethvignot, T.
    Taieb, J.
    Becker, J. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 261 (1-2): : 953 - 955
  • [6] Nondestructive Assay Measurements Using the RPI Lead Slowing-Down Spectrometer
    Becker, B.
    Weltz, A.
    Kulisek, J. A.
    Thompson, J.
    Thompson, N.
    Danon, Y.
    NUCLEAR SCIENCE AND ENGINEERING, 2013, 175 (02) : 124 - 134
  • [7] Resonance capture γ-ray spectrometry at Lead Slowing-down Neutron Spectrometer
    Pourimani, R
    Olejniczak, U
    Popov, YP
    Przytula, M
    Wojtkiewicz, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 488 (1-2): : 226 - 239
  • [8] Neutron spectroscopy on lead slowing-down neutron spectrometer at university of lodz
    Andrzejewski, J
    Wojtkiewicz, R
    Pourimani, R
    Baczynski, J
    Olejniczak, U
    Przytula, M
    INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, VOL 59, PT 1 AND 2, 1997, 59 : 541 - 543
  • [9] From my research - Nuclear data experiments with lead slowing-down spectrometer
    Kobayashi, K
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 2004, 46 (07): : 474 - 478
  • [10] Characteristics of the Kyoto University Lead Slowing-down Spectrometer (KULS) coupled to an electron linac
    Kobayashi, Katsuhei
    Yamamoto, Shuji
    Yamanaka, Akihiro
    Nakagome, Yoshihiro
    Fujita, Yoshiaki
    Kanazawa, Satoshi
    Kimura, Itsuro
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997, 385 (01): : 145 - 156