High resolution medical imaging system for 3-D imaging of radioactive sources with 1 mm FWHM spatial resolution

被引:3
|
作者
Smither, RK [1 ]
机构
[1] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
来源
MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2 | 2003年 / 5030卷
关键词
crystal; diffraction; lens; gamma rays; medical imaging; focusing; tumor; cancer;
D O I
10.1117/12.480393
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes a modification of a new imaging system developed at Argonne National Laboratory that has the potential of achieving a spatial resolution of 1 mm FWHM. The imaging system uses a crystal diffraction lens to focus gamma rays from the radioactive source. The medical imaging application of this system would be to detect small amounts of radioactivity in the human body that would be associated with cancer. The best spatial resolution obtained with the present lens at the time of the presentation made at the Medical Imaging Symposium 2001, was 6.7 mm FWHM for a 1-mm-diameter source. Since then it has been possible to improve the spacial resolution of the lens system to 3 mm FWHM. Experiments with the original lens system have led to a new design for a lens system that could have a spacial resolution of I mm FWHM. This is accomplished by: one, reducing the radial dimension of the crystals, and two, by replacing the small individual crystals with bent strips of single-crystalline material. Experiments are under way to test this approach.
引用
收藏
页码:1052 / 1060
页数:9
相关论文
共 50 条
  • [1] High resolution 3-D imaging
    Chiang, CT
    Chung, BK
    JOURNAL OF ELECTROMAGNETIC WAVES AND APPLICATIONS, 2005, 19 (09) : 1267 - 1281
  • [2] High resolution 3-D underwater imaging
    McLean, JW
    AIRBORNE AND IN-WATER UNDERWATER IMAGING, 1999, 3761 : 10 - 19
  • [3] High resolution, ultra fast 3-D imaging
    Rohály, J
    Hart, DP
    THREE-DIMENSIONAL IMAGE CAPTURE AND APPLICATIONS III, 2000, 3958 : 2 - 10
  • [4] A miniature high resolution 3-D imaging sonar
    Josserand, Tim
    Wolley, Jason
    ULTRASONICS, 2011, 51 (03) : 275 - 280
  • [5] Adaptation of Spatial Resolution for High Resolution Imaging System
    Eckardt, Andreas
    Williges, Christian
    Reulke, Ralf
    OPTICS AND PHOTONICS FOR INFORMATION PROCESSING XI, 2017, 10395
  • [6] Applications of a PET device with 1.5 mm FWHM intrinsic spatial resolution to breast cancer imaging
    Weinberg, I
    Beylin, D
    Yarnall, S
    Anashkin, E
    Stepanov, P
    Dolinsky, S
    Zavarzin, V
    Peter, W
    Lauckner, K
    Morton, K
    Freimanis, R
    Lesko, N
    Levine, E
    Perrier, N
    Lovelace, J
    Geisinger, K
    Williams, R
    Wollenweber, S
    Narayanan, D
    Doss, M
    Hummel, J
    Sigurdson, E
    Evers, K
    Torosian, M
    Adler, L
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 1396 - 1399
  • [7] High resolution digital 3-D imaging of large structures
    Rioux, M
    Beraldin, A
    Godin, G
    Blais, F
    Cournoyer, L
    THREE-DIMENSIONAL IMAGE CAPTURE, 1997, 3023 : 109 - 118
  • [8] HIGH-RESOLUTION IMAGING IN 3-D RECONSTRUCTIVE TOMOGRAPHY
    VERLY, JG
    COMPUTER GRAPHICS AND IMAGE PROCESSING, 1981, 16 (01): : 1 - 19
  • [9] A reflection based, pulsed THz imaging system with 1 mm spatial resolution
    Taylor, Z. D.
    Singh, R. S.
    Brown, E. R.
    Bjarnason, J. E.
    Hanson, M. P.
    Gossard, A. C.
    2007 IEEE/MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-6, 2007, : 1158 - 1161
  • [10] High-Resolution 3-D Imaging of Group Rotating Targets
    Bai, Xueru
    Zhou, Feng
    Bao, Zheng
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2014, 50 (02) : 1066 - 1077