Assessing the signal quality of electrocardiograms from varied acquisition sources: A generic machine learning pipeline for model generation

被引:14
|
作者
Albaba, Adnan [1 ,2 ]
Simo, Neide [1 ,2 ]
Wang, Yuyang [3 ]
Hendriks, Richard C. [3 ]
De Raedt, Walter [2 ]
Van Hoof, Chris [1 ,2 ]
机构
[1] Univ Leuven, Dept Elect Engn, Leuven, Belgium
[2] IMEC, Connected Hlth Solut Grp, Leuven, Belgium
[3] Delft Univ Technol, Dept Elect Engn, Delft, Netherlands
关键词
Electrocardiogram; Wearables; Ubiquitous; Non-contact; Classification; Feature selection; Motion artefact; Signal quality; QRS DETECTION; ECG;
D O I
10.1016/j.compbiomed.2020.104164
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background and objective: Long-term electrocardiogram monitoring comes at the expense of signal quality. During unconstrained movements, the electrocardiogram is often corrupted by motion artefacts, which can lead to inaccurate physiological information. In this situation, automated quality assessment methods are useful to increase the reliability of the measurements. A generic machine learning pipeline that generates classification models for electrocardiogram quality assessment is presented in this article. The presented pipeline is tested on signals from varied acquisition sources, towards selecting segments that can be used for heart rate analysis in lifestyle applications. Methods: Electrocardiogram recordings from traditional, wearable and ubiquitous devices, are segmented in 10 s windows and manually labeled by experienced researchers into two quality classes. To capture the electrocardiogram dynamics, a comprehensive set of 43 features is extracted from each segment, based on the time-domain signal, its Fast Fourier Transform, the Autocorrelation function and the Stationary Wavelet Transform. To select the most relevant features for each acquisition source we employ both a customized hybrid approach and the state-of-the-art Neighborhood Component Analysis method and compare them. Support Vector Machines (SVM), Decision Trees, K-Nearest-Neighbors and supervised ensemble methods are tested as possible binary classifiers. Results: The results for the best performing models on traditional, wearable and ubiquitous electrocardiogram datasets are, respectively: balanced-accuracy: 89%, F1-score: 93% with the Fine Gaussian SVM model and 10 features; balanced-accuracy: 93%, F1-score: 93% with the Fine Gaussian SVM model and 11 features; balanced accuracy: 95%, F1-score: 86%, with the Fine Gaussian SVM model and 8 features. Conclusions: According to the results, our generic pipeline can generate classification models tailored to individual acquisition sources, provided that a standard Lead I or Lead II is available. Such models accurately establish whether the electrocardiogram quality is good or bad for heart rate analysis. Furthermore, removing bad quality segments decreases errors in heart rate calculation.
引用
收藏
页数:11
相关论文
共 38 条
  • [1] An ECG Signal Acquisition and Analysis System Based on Machine Learning with Model Fusion
    Su, Shi
    Zhu, Zhihong
    Wan, Shu
    Sheng, Fangqing
    Xiong, Tianyi
    Shen, Shanshan
    Hou, Yu
    Liu, Cuihong
    Li, Yijin
    Sun, Xiaolin
    Huang, Jie
    SENSORS, 2023, 23 (17)
  • [2] Machine Learning approach for global no-reference video quality model generation
    Saidi, Ines
    Zhang, Lu
    Barriac, Vincent
    Deforges, Olivier
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XLI, 2018, 10752
  • [3] A General Machine Learning Model for Assessing Fruit Quality Using Deep Image Features
    Apostolopoulos, Ioannis D.
    Tzani, Mpesi
    Aznaouridis, Sokratis I.
    AI, 2023, 4 (04) : 812 - 830
  • [4] Development and validation of a machine learning model to predict myocardial blood flow and clinical outcomes from patients' electrocardiograms
    Alahdab, Fares
    Saad, Maliazurina Binti
    Ahmed, Ahmed Ibrahim
    Al Tashi, Qasem
    Aminu, Muhammad
    Han, Yushui
    Moody, Jonathan B.
    Murthy, Venkatesh L.
    Wu, Jia
    Al-Mallah, Mouaz H.
    CELL REPORTS MEDICINE, 2024, 5 (10)
  • [5] From COVID-19 to future electrification: Assessing traffic impacts on air quality by a machine-learning model
    Yang, Jiani
    Wen, Yifan
    Wang, Yuan
    Zhang, Shaojun
    Pinto, Joseph P.
    Pennington, Elyse A.
    Wang, Zhou
    Wu, Ye
    Sander, Stanley P.
    Jiang, Jonathan H.
    Hao, Jiming
    Yung, Yuk L.
    Seinfeld, John H.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2021, 118 (26)
  • [6] A Machine Learning Pipeline for Predicting Pinot Noir Wine Quality from Viticulture Data: Development and Implementation
    Kulasiri, Don
    Somin, Sarawoot
    Pathirannahalage, Samantha Kumara
    FOODS, 2024, 13 (19)
  • [7] Assessing Electrocardiogram and Respiratory Signal Quality of a Wearable Device (SensEcho): Semisupervised Machine Learning-Based Validation Study
    Xu, Haoran
    Yan, Wei
    Lan, Ke
    Ma, Chenbin
    Wu, Di
    Wu, Anshuo
    Yang, Zhicheng
    Wang, Jiachen
    Zang, Yaning
    Yan, Muyang
    Zhang, Zhengbo
    JMIR MHEALTH AND UHEALTH, 2021, 9 (08):
  • [8] GigMaleBPMN: Generation of Graphical Components from the BPMN Model using Machine Learning
    De La Cruz, Marco Antonio
    Estrada, Luis Miguel
    Diaz, Eduardo
    Panach, Jose Ignacio
    2023 FOURTH INTERNATIONAL CONFERENCE ON INFORMATION SYSTEMS AND SOFTWARE TECHNOLOGIES, ICI2ST 2023, 2023, : 97 - 103
  • [9] Automatic Surrogate Model Generation and Debugging of Analog/Mixed-Signal Designs Via Collaborative Stimulus Generation and Machine Learning
    Lei, Jun Yang
    Chatterjee, Abhijit
    2021 26TH ASIA AND SOUTH PACIFIC DESIGN AUTOMATION CONFERENCE (ASP-DAC), 2021, : 140 - 145
  • [10] A machine learning model pipeline for detecting wet pavement condition from live scenes of traffic cameras
    Morris, Clint
    Yang, Jidong J.
    MACHINE LEARNING WITH APPLICATIONS, 2021, 5