Functional Screening of Intracardiac Cell Transplants Using Two-Photon Fluorescence Microscopy

被引:8
|
作者
Tao, Wen [1 ]
Soonpaa, Mark H. [1 ,2 ]
Field, Loren J. [1 ,2 ]
Chen, Peng-Sheng [2 ]
Firulli, Anthony B. [1 ]
Shou, Weinian [1 ]
Rubart, Michael [1 ]
机构
[1] Indiana Univ Sch Med, Dept Pediat, Riley Heart Res Ctr, Indianapolis, IN 46202 USA
[2] Indiana Univ Sch Med, Div Cardiol, Dept Med, Krannert Inst Cardiol, Indianapolis, IN 46202 USA
关键词
Cellular transplantation; Intracellular calcium regulation; Myocardial regeneration; Two-photon fluorescence microscopy; EMBRYONIC STEM-CELLS; ACUTE MYOCARDIAL-INFARCTION; EXCITATION MICROSCOPY; CARDIAC MYOCYTES; CARDIOMYOCYTES; REGENERATION; GENERATION; TRANSIENTS; HUMANS; HEARTS;
D O I
10.1007/s00246-012-0314-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although the adult mammalian myocardium exhibits a limited ability to undergo regenerative growth, its intrinsic renewal rate is insufficient to compensate for myocyte loss during cardiac disease. Transplantation of donor cardiomyocytes or cardiomyogenic stem cells is considered a promising strategy for reconstitution of cardiac mass, provided the engrafted cells functionally integrate with host myocardium and actively contribute to its contractile force. The authors previously developed a two-photon fluorescence microscopy-based assay that allows in situ screening of donor cell function after intracardiac delivery of the cells. This report reviews the techniques of two-photon fluorescence microscopy and summarizes its application for quantifying the extent to which a variety of donor cell types stably and functionally couple with the recipient myocardium.
引用
收藏
页码:929 / 937
页数:9
相关论文
共 50 条
  • [1] Functional Screening of Intracardiac Cell Transplants Using Two-Photon Fluorescence Microscopy
    Wen Tao
    Mark H. Soonpaa
    Loren J. Field
    Peng-Sheng Chen
    Anthony B. Firulli
    Weinian Shou
    Michael Rubart
    Pediatric Cardiology, 2012, 33 : 929 - 937
  • [2] Two-photon excitation fluorescence microscopy
    So, PTC
    Dong, CY
    Masters, BR
    Berland, KM
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2000, 2 : 399 - 429
  • [3] Two-photon excitation fluorescence microscopy and its application in functional connectomics
    Nemoto, Tomomi
    Kawakami, Ryosuke
    Hibi, Terumasa
    Iijima, Koichiro
    Otomo, Kohei
    MICROSCOPY, 2015, 64 (01) : 9 - 15
  • [4] Adaptive optics two-photon fluorescence microscopy
    Zhou, Yaopeng
    Bifano, Thomas
    Lin, Charles
    MEMS ADAPTIVE OPTICS, 2007, 6467
  • [5] Two-photon fluorescence surface wave microscopy
    Goh, JYL
    Somekh, MG
    See, CW
    Pitter, MC
    Vere, KA
    O'Shea, P
    JOURNAL OF MICROSCOPY, 2005, 220 : 168 - 175
  • [6] New trends in two-photon fluorescence microscopy
    So, PTC
    BIOPHYSICAL JOURNAL, 1998, 74 (02) : A8 - A8
  • [7] Gold nanorods for cell imaging with confocal reflectance microscopy and two-photon fluorescence microscopy
    Chen, Ji-Yao
    Wang, Pei-Nan
    IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES VIII, 2010, 7568
  • [8] Two-photon fluorescence microscopy with differential aberration imaging
    Chu, Kengyeh K.
    Leray, Aymeric
    Bifano, Thomas G.
    Mertz, Jerome
    MEMS ADAPTIVE OPTICS III, 2009, 7209
  • [9] Two-photon fluorescence correlation microscopy for biophysical studies
    Tatarkova, SA
    Lloyd, C
    Berk, DA
    SARATOV FALL MEETING 2000: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE II, 2001, 4241 : 312 - 316
  • [10] Highly nonlinear photodamage in two-photon fluorescence microscopy
    Hopt, A
    Neher, E
    BIOPHYSICAL JOURNAL, 2001, 80 (04) : 2029 - 2036