Development of fast-response portable NDIR analyzer using semiconductor devices

被引:4
|
作者
Kim, WS
Lee, JH
Park, YM
Yoo, JS
Park, KS
机构
[1] Ajou Univ, Thermo Mech Properties Lab, Suwon 441749, South Korea
[2] Kumoh Natl Univ Technol, Sch Mech Engn, Kumi Kyungbuk, South Korea
来源
KSME INTERNATIONAL JOURNAL | 2003年 / 17卷 / 12期
关键词
fast-response NDIR Analyzer (FRNDIR); CO2; concentration; lead selenide; light emitter; dual type detector; detector sensitivity; transit time; time constant;
D O I
10.1007/BF02982450
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In this paper, a novel fast response NDIR analyzer (FRNDIR), which uses an electrically pulsed semiconductor emitter and dual type PbSe detector for the PPM-level detection of carbon dioxide (CO2) at a wavelength of 4.28 mum, is described. Modulation of conventional NDIR energy typically occurs at 1 to 20 Hz. To achieve real time high-speed measurement, the new analyzer employs a semiconductor light emitter that can be modulated by electrical chopping. Updated measurements are obtained every one millisecond. The detector has two independent lead selenide (PbSe) with IR band pass filters. Both the emitter accuracy and the detector sensitivity are increased by thermoelectric cooling of up to -20 degrees C in all semiconductor devices. Here we report the use of semiconductor devices to achieve improved performance such that these devices have potential application to CO2 gas measurement and, in particular, the measurement of fast response CO2 concentration at millisecond level.
引用
收藏
页码:2099 / 2106
页数:8
相关论文
共 50 条
  • [1] Development of fast-response portable NDIR analyzer using semiconductor devices
    Woo-Seok Kim
    Jong-Hwa Lee
    Young-Moo Park
    Jai-Suk Yoo
    Kyoung Seok Park
    KSME International Journal, 2003, 17 : 2099 - 2106
  • [2] A PORTABLE FAST-RESPONSE TRANSIENT-VOLTAGE COUNTER
    CHOWDHURI, P
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (05): : 417 - +
  • [3] Development of a Compact NDIR CO2 Gas Sensor for a Portable Gas Analyzer
    Xu, Maosen
    Tian, Wei
    Lin, Yuzhe
    Xu, Yan
    Tao, Jifang
    MICROMACHINES, 2024, 15 (10)
  • [4] Fast-response gas analyzer by the use of an infrared hollow fibre
    Saito, M
    Okubo, Y
    Kato, T
    17th International Conference on Optical Fibre Sensors, Pts 1 and 2, 2005, 5855 : 920 - 923
  • [5] A FAST-RESPONSE, OPEN-PATH, INFRARED HYGROMETER, USING A SEMICONDUCTOR SOURCE
    GREEN, AE
    KOHSIEK, W
    BOUNDARY-LAYER METEOROLOGY, 1995, 74 (04) : 353 - 370
  • [6] The FOZAN-II Fast-Response Chemiluminescent Airborne Ozone Analyzer
    A. E. Ulanovsky
    V. A. Yushkov
    N. M. Sitnikov
    F. Ravengnani
    Instruments and Experimental Techniques, 2001, 44 : 249 - 256
  • [7] A FAST-RESPONSE OXYGEN ANALYZER WITH HIGH ACCURACY FOR RESPIRATORY GAS MEASUREMENT
    SODAL, IE
    BOWMAN, RR
    FILLEY, GF
    JOURNAL OF APPLIED PHYSIOLOGY, 1968, 25 (02) : 181 - &
  • [8] The FOZAN-II fast-response chemiluminescent airborne ozone analyzer
    Ulanovsky, AE
    Yushkov, VA
    Sitnikov, NM
    Ravegnani, F
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2001, 44 (02) : 249 - 256
  • [9] The development of a fast-response portable photo-ionization detector: a model of the instrument's response and validation tests in air
    Griffiths, RF
    Mavroidis, I
    Jones, CD
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1998, 9 (09) : 1369 - 1379
  • [10] Development of a fast-response portable photo-ionization detector: A model of the instrument's response and validation tests in air
    Univ of Manchester Inst of Science, and Technology, Manchester, United Kingdom
    Meas Sci Technol, 9 (1369-1379):