Strain shielding inspired re-design of proximal femoral stems for total hip arthroplasty

被引:31
|
作者
Cilla, Myriam [1 ,2 ,3 ]
Checa, Sara [1 ,4 ,5 ]
Duda, Georg N. [1 ,4 ,5 ]
机构
[1] Charite Univ Med Berlin, Julius Wolff Inst, Campus Virchow Klinikum, Augustenburger Pl 1, D-13353 Berlin, Germany
[2] Acad Gen Mil, Ctr Univ Def, Ctra Huesca S-N, Zaragoza 50090, Spain
[3] Univ Zaragoza, Aragon Inst Engn Res I3A, Zaragoza, Spain
[4] Charite Univ Med Berlin, Berlin Brandenburg Sch Regenerat Therapies, Berlin, Germany
[5] Charite Univ Med Berlin, Berlin Brandenburg Ctr Regenerat Therapies, Berlin, Germany
关键词
bone; computational modeling; hip and knee arthroplasty; finite element analysis; mechanicskinematics; hip; FINITE-ELEMENT MODELS; SHAPE OPTIMIZATION; BONE-DENSITY; DESIGN; PROSTHESIS; COMPONENT; IMPLANT; FEMUR; REPLACEMENT; SENSITIVITY;
D O I
10.1002/jor.23540
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A large number of hip prosthesis with different designs have been developed. However, the influence of hip implant design changes on the strains induced in the bone remains unclear. The purpose of this study is to better understand the mechanics of short stem total hip arthroplasty. Specifically, it investigates whether strain shielding can be avoided by changing implant shape and/or material properties. It is hypothesized that the re-design of existing implant designs can result in further reduction of strain shielding and thus keep bone loss minimal following total hip replacement. Finite element methods were used to compare healthy and implanted models. The local mechanics strains/stresses in the intact and implanted femurs were determined under patient-specific muscle and joint contact forces. Results suggest that small changes in implant geometry and material properties have no major effect on strain shielding. Furthermore, it was found that improvement depends on a dramatic re-design of the original implant design. Whereas the benefit of this strategy of modification of the original geometry of a given short-stemmed hip consists in reduced bone remodeling, care should be taken with regard to long-term bone anchorage and implant fatigue strength. It is also shown that geometrical and material changes have a limited potential in avoiding strain shielding even in short-stemmed implants. Finally, it is suggested that an understanding of the influence of these changes on the strain distribution within the bone can guide in the process of optimizing the current stem designs toward minimal strain shielding effects. (c) 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2534-2544, 2017.
引用
收藏
页码:2534 / 2544
页数:11
相关论文
共 50 条
  • [1] Capability of auxetic femoral stems to reduce stress shielding after total hip arthroplasty
    Liu, Bolun
    Wang, Huizhi
    Zhang, Min
    Li, Junwei
    Zhang, Ningze
    Luan, Yichao
    Fang, Chaohua
    Cheng, Cheng-Kung
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2023, 38 : 220 - 228
  • [2] Bimodular femoral stems in primary total hip arthroplasty
    Zajc, Jan
    Fokter, Samo K.
    EXPERT REVIEW OF MEDICAL DEVICES, 2023, 20 (12) : 1051 - 1064
  • [3] Modular Femoral Stems for Revision Total Hip Arthroplasty
    Restrepo, Camilo
    Mashadi, Magdalena
    Parvizi, Javad
    Austin, Matthew S.
    Hozack, William J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (02) : 476 - 482
  • [4] Uncemented Collared Femoral Stems in Total Hip Arthroplasty
    Lemme, Nicholas J.
    McDonald, Christopher L.
    Hamilton, William G.
    Crisco, Joseph J.
    Cohen, Eric M.
    ORTHOPEDICS, 2022, 45 (03) : E122 - +
  • [5] Revision Total Hip Arthroplasty With Modular Femoral Stems
    Stimac, Jeffrey D.
    Boles, John
    Parkes, Natalie
    Della Valle, Alejandro Gonzalez
    Boettner, Friedrich
    Westrich, Geoffrey H.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (11): : 2167 - 2170
  • [6] Total hip arthroplasty with femoral osteotomy for proximal femoral deformity
    Papagelopoulos, PJ
    Trousdale, RT
    Lewallen, DG
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (332) : 151 - 162
  • [7] Cementless Tapered Femoral Stems for Total Hip Arthroplasty in Octogenarians
    Riley, Stephanie A.
    Spears, James R.
    Smith, Langan S.
    Mont, Michael A.
    Elmallah, Randa K.
    Cherian, Jeffrey J.
    Malkani, Arthur L.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (12): : 2810 - 2813
  • [8] PROXIMAL FEMORAL REPLACEMENT TOTAL HIP-ARTHROPLASTY
    ROOSE, PE
    JOURNAL OF THE AMERICAN OSTEOPATHIC ASSOCIATION, 1979, 78 (09): : 666 - 670
  • [9] Total hip arthroplasty in patients with proximal femoral deformity
    Berry, DJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (369) : 262 - 272
  • [10] Total hip arthroplasty for complications of proximal femoral fractures
    Tabsh, I
    Waddell, JP
    Morton, J
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (03) : 166 - 169