Converter Outage Fault Ride-Through Control Strategy for Offshore MT-HVDC Network

被引:0
|
作者
Abdelwahed, Mohamed A. [1 ]
El-Saadanv, Ehab [1 ,2 ]
机构
[1] Univ Waterloo, ECE Dept, Waterloo, ON N21 3G1, Canada
[2] PI, Abu Dhabi, U Arab Emirates
关键词
FRT; MT VSC-HVDC; Offshore wind power integration; Type 4 wind generator; Wind Farms; DC TRANSMISSION-SYSTEMS; MULTITERMINAL HVDC; WIND TURBINES; STABILITY; FARMS; AC;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
This paper presents a fault ride through (FRT) control strategy for offshore MT HVDC (multi-terminal high voltage DC), which integrates type-4 wind-turbine based offshore-wind farms. The proposed control strategy are responsible for relieving DC voltage rise effects during a temporary grid side (GS) converter outage, by setting local measurements and communication free control rules in wind farm (WF) converters and wind generators local controllers. The functionality and feasibility of the proposed control strategy are presented in this paper through simulations of a three terminals offshore HVDC network system.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] A fault ride-through strategy for accurate energy optimization of offshore wind VSC-HVDC system without improved fault ride-through strategy of wind turbines
    Xiao, Fan
    Yin, Xin
    Tang, Jinrui
    He, Qingqing
    Zhou, Keliang
    Tang, Chao
    Liu, Dan
    Ji, Xiaotong
    COMPUTERS & ELECTRICAL ENGINEERING, 2024, 118
  • [2] Additional AC Fault Ride-through Control Strategy of MMC-HVDC Connected to a Passive Network
    Wang Y.
    Chen S.
    Zeng Q.
    Luo L.
    Ye W.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (05): : 1658 - 1665
  • [3] Fault Ride-Through of HVDC Connected Large Offshore Wind Farms
    Xu, Lie
    Yao, Liangzhong
    Green Energy and Technology, 2012, 78 : 415 - 430
  • [5] Zero DC Voltage Control Based DC Fault Ride-Through Strategy for Hybrid Modular Multilevel Converter in HVDC
    Yin T.
    Wang Y.
    Duan G.
    Liu G.
    Hu S.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2019, 34 : 343 - 351
  • [6] Asymmetrical Fault Ride-Through Control Strategy for Rotor-Side Converter of DFIG
    Chen, Linhao
    Zhang, Baohui
    Fan, Xinkai
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2020, 35 (02) : 1046 - 1053
  • [7] Control strategy used for AC fault ride-through in VSC-HVDC transmission systems
    Baazouzi, Mansour
    Sayahi, Kamel
    Bacha, Faouzi
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2025, 47 (07) : 1237 - 1248
  • [8] Asymmetrical Fault Ride-Through Control Strategy for Rotor-Side Converter of DFIG
    Chen, Linhao
    Zhang, Baohui
    Fan, Xinkai
    IEEE Transactions on Energy Conversion, 2020, 35 (02): : 1046 - 1053
  • [9] Fault Ride-through Strategy and Protection Setting Optimization of Converter Valve for Zhangbei VSC-HVDC Grid
    Guo X.
    Li T.
    Li G.
    Wei Z.
    Yuan B.
    Chen D.
    Li, Tan (litan@chinasperi.sgcc.com.cn), 2018, Automation of Electric Power Systems Press (42): : 196 - 202
  • [10] Research on Topology and Fault Ride-through Strategy of Converter Embedded MMC
    Zhu W.
    Zhao X.
    Zhao C.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (21): : 8434 - 8443