Energy cost of walking measurements in subjects with lower limb amputations: A comparison study between floor and treadmill test

被引:67
|
作者
Traballesi, Marco [1 ]
Porcacchia, Paolo [1 ]
Averna, Tiziano [1 ]
Brunelli, Stefano [1 ]
机构
[1] Hospitalizat & Healthcare, Sci Inst Res, Unita Operat D Fdn Santa Lucia, I-00179 Rome, Italy
关键词
amputees; walking; oxygen consumption; human locomotion;
D O I
10.1016/j.gaitpost.2007.01.006
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Measuring the energy cost of walking (ECW) is a valid way of assessing the walking efficiency of subjects who were prosthetic users following lower limb amputation. The aim of this study was to determine whether, in these subjects, treadmill and floor ECW measurements are comparable. We tested 24 subjects who had undergone unilateral lower limb amputations for vascular diseases as they walked at a self-selected comfortable speed on the floor and on a treadmill. The tests were conducted at the end of rehabilitative treatment to fit prosthesis. Eight subjects underwent transtibial and 16 transfemoral amputation. The measurements were taken with a portable gas analyzer. The self-selected comfortable speed on the treadmill was significantly lower than that on the floor, where the patients adopted the aid they normally used for walking; oxygen consumption was the same in the two tests. Therefore, for both transtibial and transfemoral patients, ECW was greater during walking on the treadmill. Steady-state heart rate did not differ in the two tests. The data show that the ECW values of the amputated subjects obtained on the treadmill at the end of rehabilitation did not correspond with those they obtained on the floor. The floor test is the one that may better reflect walking with prostheses and aids in everyday life, in subjects with dysvascular lower limb amputation, using the prosthesis for a short time. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:70 / 75
页数:6
相关论文
共 50 条
  • [2] ENERGY-COST OF TREADMILL AND FLOOR WALKING AT SELF-SELECTED PACES
    PEARCE, ME
    CUNNINGHAM, DA
    DONNER, AP
    RECHNITZER, PA
    FULLERTON, GM
    HOWARD, JH
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1983, 52 (01): : 115 - 119
  • [4] Comparison of walking variations during treadmill walking test between neurogenic and vascular claudication: a crossover study
    Mariève Houle
    Julie O’Shaughnessy
    Charles Tétreau
    Claude-Édouard Châtillon
    Andrée-Anne Marchand
    Martin Descarreaux
    Chiropractic & Manual Therapies, 29
  • [5] Comparison of energy cost between genders during treadmill walking at a self-selected pace
    Krinski, Kleverton
    Elsangedy, Hassan Mohamed
    Krause, Maressa Priscila
    Timossi, Luciana da Silva
    da Silva, Sergio Gregorio
    ACTA SCIENTIARUM-HEALTH SCIENCES, 2012, 34 (02) : 145 - 150
  • [6] Comparison of walking variations during treadmill walking test between neurogenic and vascular claudication: a crossover study
    Houle, Marieve
    O'Shaughnessy, Julie
    Tetreau, Charles
    Chatillon, Claude-Edouard
    Marchand, Andree-Anne
    Descarreaux, Martin
    CHIROPRACTIC & MANUAL THERAPIES, 2021, 29 (01)
  • [7] Comparison of the metabolic energy cost of overground and treadmill walking in older adults
    Nicolas Berryman
    Mathieu Gayda
    Anil Nigam
    Martin Juneau
    Louis Bherer
    Laurent Bosquet
    European Journal of Applied Physiology, 2012, 112 : 1613 - 1620
  • [8] Comparison of the metabolic energy cost of overground and treadmill walking in older adults
    Berryman, Nicolas
    Gayda, Mathieu
    Nigam, Anil
    Juneau, Martin
    Bherer, Louis
    Bosquet, Laurent
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (05) : 1613 - 1620
  • [9] Influence of walking speed on lower limb muscle activity and energy consumption during treadmill walking of hemiparetic patients
    Hesse, S
    Werner, C
    Paul, T
    Bardeleben, A
    Chaler, J
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2001, 82 (11): : 1547 - 1550
  • [10] Comparison of Motion Analysis and Energy Expenditures between Treadmill and Overground Walking
    Sohn, R. H.
    Hwang, S. H.
    Kim, Y. H.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 1928 - 1930