Galfenol Resonant Sensor for Indirect Wireless Osteosynthesis Plate Bending Measurements

被引:0
|
作者
Fischer, W. J. [1 ]
Sauer, S. [1 ]
Marschner, U. [1 ]
Adolphi, B. [1 ]
Wenzel, C. [1 ]
Jettkant, B. [2 ]
Clasbrummel, B. [2 ]
机构
[1] Tech Univ Dresden, Inst Semicond & Microsyst Technol, Dresden, Germany
[2] Berufsgenossenschaftliches Univ Klinikum, Dresden, Germany
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The healing process of bone fractures can be monitored by a measurement of the osteosynthesis plate bending. An electrical resonant circuit consisting of a coil with a magnetostrictive Galfenol core and a capacitance enables an indirect wireless measurement of the plate bending. The Galfenol core is manufactured with a thin film technology using a Galfenol Fe83Ga17 alloy. The sensor has a quit good linear resonant frequency-force characteristic. Both, time and frequency domain measurement techniques for the sensor, use an external measurement coil. In the frequency domain the transformed sensor impedance is evaluated and the resonance frequency is determined by a local extremum. In the time domain a short energizing sinus pulse is transmitted, the sensor response is received and a frequency counting, Fourier or Wavelet technique is used for resonance frequency detection.
引用
收藏
页码:613 / +
页数:2
相关论文
共 50 条
  • [1] Passive Wireless Resonant Galfenol Sensor for Osteosynthesis Plate Bending Measurement
    Sauer, Sebastian
    Marschner, Uwe
    Adolphi, Barbara
    Clasbrummel, Bernhard
    Fischer, Wolf-Joachim
    IEEE SENSORS JOURNAL, 2012, 12 (05) : 1226 - 1233
  • [2] Resonant bending sensor based on sputtered Galfenol
    Wenzel, C.
    Adolphi, B.
    Merkel, U.
    Jahn, A.
    Marschner, U.
    Ziske, J.
    Neubert, H.
    Fischer, W. -J.
    SENSORS AND ACTUATORS A-PHYSICAL, 2009, 156 (01) : 129 - 133
  • [3] Magnetoelastic bending of Galfenol for sensor applications
    Downey, PR
    Flatau, AB
    JOURNAL OF APPLIED PHYSICS, 2005, 97 (10)
  • [4] Bending of iron-gallium (Galfenol) alloys for sensor applications
    Downey, Patrick R.
    Flatau, Alison B.
    SMART STRUCTURES AND MATERIALS 2006: SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL , AND AEROSPACE SYSTEMS, PTS 1 AND 2, 2006, 6174
  • [5] Bending of iron-gallium (Galfenol) alloys for sensor applications
    Downey, Patrick R.
    Flatau, Alison B.
    MATERIAL AND DEVICES FOR SMART SYSTEMS II, 2006, 888 : 341 - +
  • [6] Bending behavior of iron-gallium (Galfenol) alloys for sensor applications
    Downey, PR
    Flatau, AB
    Smart Structures and Materials 2005: Smart Structures and Integrated Systems, 2005, 5764 : 120 - 129
  • [7] Thin Film Plate Wave Resonant Sensor for Pressure and Gravimetric Measurements
    Anderas, E.
    Arapan, L.
    Katardjiev, I.
    Yantchev, V.
    EUROSENSORS XXV, 2011, 25
  • [8] Modeling of magnetostrictive Galfenol sensor and validation using four point bending test
    Datta, Supratik
    Atulasimha, Jayasimha
    Flatau, Alison B.
    JOURNAL OF APPLIED PHYSICS, 2007, 101 (09)
  • [9] A COMPARISON OF TORQUE MEASUREMENTS OF PLATE OSTEOSYNTHESIS AND IMPLANT REMOVAL
    MATTER, P
    SENN, E
    HIMMELBERGER, C
    UNFALLHEILKUNDE-TRAUMATOLOGY, 1980, 83 (05): : 184 - 187
  • [10] BENDING AND TORSION STRENGTH OF HEALED METATARSAL OSTEOTOMIES FOLLOWING PLATE OSTEOSYNTHESIS
    HUTZSCHENREUTER, P
    CLAES, L
    BICK, R
    HELVETICA CHIRURGICA ACTA, 1978, 45 (1-2) : 133 - 136