Cross-correlation Phase Correction Method on Ultrasonic Synthetic Focused Signal Distortion

被引:0
|
作者
Ye, Cai-qun [1 ]
Luo, Lin
Gao, Xiao-rong
Jiang, Li-rong
Yue, Hai-lin
机构
[1] Southwest Jiaotong Univ, Photoelect Engn Inst, Chengdu 610031, Peoples R China
关键词
ultrasonic synthetic aperture; ultrasound imaging; phase correction; inhomogeneity; ABERRATION CORRECTION; SONAR SYSTEM; ALGORITHM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Synthetic aperture ultrasonic imaging is currently widely used in railway, aviation, automobile manufacturing and petrochemical, major in non-destructive testing the defects of key components and materials, and showing them in form of image. Due to inhomogeneity of testing materials and errors of detection systems, detected signals have phase errors, and distortion exists on synthesis images. This paper presents an effective phase correction method on ultrasonic synthetic focused signal distortion. A parameter, the relative signal-to-noise ratio, is introduced to be the indicator for later analysis. Via experimental results and the relative signal-to-noise ratios of the synthetic focusing images before and after phase correlation, the feasibility of the program is proved. Thus, the phase correction method here is worth putting the use into various ultrasonic application fields.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] ULTRASONIC CROSS-CORRELATION FLOWMETERS
    COULTHARD, J
    ULTRASONICS, 1973, 11 (02) : 83 - 88
  • [2] Ultrasonic cross-correlation flowmeters
    Coulthard, J.
    Yan, Y.
    Measurement and Control, 1993, 26 (06) : 164 - 167
  • [3] Defect mapping in pipes by ultrasonic wavefield cross-correlation: A synthetic verification
    Nguyen, Luan T.
    Kocur, Georg K.
    Saenger, Erik H.
    ULTRASONICS, 2018, 90 : 153 - 165
  • [4] Synthetic turbulence modeling for evaluation of ultrasonic cross-correlation flow measurement
    Gurevich, Alexander Y.
    Goman, Mikhail G.
    Gurevich, Yuri G.
    Lopez, Armando M.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2018, 60 : 134 - 143
  • [5] Modified GSC Method to Reduce the Distortion of the Enhanced Speech Signal Using Cross-Correlation and Sidelobe Neutralization
    Su, Hang
    Lee, Chang-Myung
    APPLIED SCIENCES-BASEL, 2021, 11 (14):
  • [6] Design and Implementation of an Ultrasonic Flowmeter Based on the Cross-Correlation Method
    Ren, Rui
    Wang, Hongliang
    Sun, Xiaolei
    Quan, He
    SENSORS, 2022, 22 (19)
  • [7] Design of Ultrasonic Ranging System Based on Cross-correlation Method
    Lu, Han
    Li, Zhihua
    Gao, Pei
    PROCEEDINGS OF THE 39TH CHINESE CONTROL CONFERENCE, 2020, : 3573 - 3582
  • [8] A NEW METHOD FOR THE DEMODULATION OF ULTRASONIC SIGNALS FOR CROSS-CORRELATION FLOWMETERS
    JACOBSON, SA
    DENBIGH, PN
    NAUDE, DEH
    ULTRASONICS, 1985, 23 (03) : 128 - 132
  • [9] Normalized Cross-Correlation Based Global Distortion Correction in Fingerprint Image Matching
    Derman, Ekberjan
    Keskinoz, Mehrnet
    PROCEEDINGS OF THE 23RD INTERNATIONAL CONFERENCE ON SYSTEMS, SIGNALS AND IMAGE PROCESSING, (IWSSIP 2016), 2016, : 153 - 156
  • [10] Correction Technique of Phase Aberration in Ultrasonic Synthetic Focusing Signal
    Yue, Hai-lin
    Luo, Lin
    Gao, Xiao-rong
    2014 IEEE FAR EAST FORUM ON NONDESTRUCTIVE EVALUATION/TESTING (FENDT), 2014, : 74 - 78