Design of compact absorbers for high-heat-load X-ray undulator beamlines at SPring-8

被引:13
|
作者
Mochizuki, T [1 ]
Sakurai, Y
Shu, D
Kuzay, TM
Kitamura, H
机构
[1] JASRI, Kamigori, Hyogo 67812, Japan
[2] RIKEN, Kamigori, Hyogo 67812, Japan
[3] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
关键词
undulator beamlines; front ends; high-heat-load components; absorbers;
D O I
10.1107/S0909049598000387
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A compact and high-heat-load absorber for the SPring-8 X-ray undulator beamline has been developed and installed. It consists of an upper heat-absorber part and a lower photon duct part, which are configured together in a water-cooled GlidCop body. The absorber part has a horizontal notch shape and the photon duct part forms a rectangular open channel under the absorber part. Two types of absorber are designed: one, with wire mesh channels, is 386 mm long, 70 mm high and 64 mm wide; the other, with smooth-bore channels, is 610 mm long, 75 mm high and 70 mm wide. Thermal and stress analyses show that they withstand the 12.3 kW heat load and the maximum heat flux of 940 W mm(-2) at normal incidence.
引用
收藏
页码:1199 / 1201
页数:3
相关论文
共 50 条
  • [1] Design of compact absorbers for high-heat-load X-ray undulator beamlines at SPring-8
    Mochizuki, T.
    Sakurai, Y.
    Shu, D.
    Kuzay, T.M.
    Kitamura, H.
    Journal of Synchrotron Radiation, 1998, 5 (04): : 1199 - 1201
  • [2] Allowable aperture size of the front end for the high-heat-load undulator beamlines of SPring-8
    Oura, M
    Sakae, H
    Sakurai, Y
    Kitamura, H
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 609 - 611
  • [3] Water cooled first crystal as a solution for high-heat-load problem at the SPring-8 undulator beamlines
    Ishikawa, T
    Yamazaki, H
    Tamasaku, K
    Yabashi, M
    Kuroda, M
    Goto, S
    CRYSTAL AND MULTILAYER OPTICS, 1998, 3448 : 2 - 10
  • [4] Water-cooled first crystals for the SPring-8 x-ray undulator beamlines
    Yamazaki, H
    Kimura, H
    Kagaya, I
    Yamashita, C
    Ishikawa, T
    X-RAY OPTICS DESIGN, PERFORMANCE, AND APPLICATIONS, 1999, 3773 : 21 - 29
  • [5] Vacuum system of X-ray beamlines of SPring-8
    Ohashi, H
    Goto, S
    Kishimoto, H
    Murase, T
    Isshiki, M
    Suzuki, Y
    Kimura, H
    Takeshita, K
    Ishikawa, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 801 - 804
  • [6] Transport channels of X-ray beamlines at SPring-8
    Goto, S
    Ohashi, H
    Takeshita, K
    Yabashi, M
    Yamakata, A
    Asano, Y
    Ishikawa, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 813 - 815
  • [7] Blade-type X-ray beam position monitors for SPring-8 undulator beamlines
    Aoyagi, H
    Kudo, T
    Kitamura, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 252 - 255
  • [8] Development of a High-Heat-Load Compact Photon Absorber for SPring-8 Diagnostics Beamline II
    Tamura, K.
    Oishi, M.
    Ohkuma, H.
    Okayasu, Y.
    Shoji, M.
    Takano, S.
    Taniuchi, Y.
    Masaki, M.
    Mochihashi, A.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [9] Design of a pre-slit for SPring-8 undulator beamlines
    Takahashi, S.
    Sakurai, Y.
    Kitamura, H.
    Journal of Synchrotron Radiation, 1998, 5 (03): : 581 - 583
  • [10] Design of a pre-slit for SPring-8 undulator beamlines
    Takahashi, S
    Sakurai, Y
    Kitamura, H
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 581 - 583